Outdoor Fiber Cable

GYTS 8F / 12F / 24F 8.6mm Loose Tube Steel-Tape Armored Fiber Optic Cable

GYTS 8F / 12F / 24F 8.6mm Loose Tube Steel-Tape Armored Fiber Optic Cable for outdoor plant use at 8F / 12F / 24F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

GYTS

What This GYTS Record Covers

This page is reserved for the BWNFiber GYTS working record that combines 8F, 12F, or 24F G.652.D fiber, a PE outer sheath, a steel-wire central strength member, corrugated steel-tape armor, and a source-listed 8.6 ± 0.3 mm outer-sheath diameter.

Choose one fiber count and keep its tube and filler arrangement with the same configuration. Do not substitute values from another 24F GYTS datasheet merely because the family name and fiber count are similar. Before quotation approval or production release, request the current controlled datasheet or drawing and resolve every field marked TBC.

Buyer short answer: For a configuration review, send the required fiber count, installation route, total length, drum or roll lengths, quantity, sheath marking, delivery destination, and required approval documents. BWNFiber should return the applicable configuration record and identify any open technical fields before the order is released.

Key Configuration Points

  • Fiber count: select 8F, 12F, or 24F.
  • Fiber grade: G.652.D in the supplied V4 record.
  • Outer sheath: PE in the supplied V4 record; color and project rating are TBC.
  • Source-listed outer diameter: 8.6 ± 0.3 mm.
  • Central strength member: steel wire.
  • Armor: corrugated steel tape.
  • Loose tube: 1.6 ± 0.1 mm PBT.
  • Release condition: approved source revision and engineering confirmation required.

Count-Specific Cable Construction

The V4 table appears to group 8F and 12F together and to list a separate 24F tube/filler arrangement. Because the original workbook and source-row map were not supplied, the alignment below is a working interpretation, not a released specification.

Selected countNumber of loose tubesNumber of fillersTube diameterStatus
8F231.6 ± 0.1 mmTBC — confirm against original workbook/drawing
12F231.6 ± 0.1 mmTBC — confirm against original workbook/drawing
24F411.6 ± 0.1 mmTBC — confirm against original workbook/drawing and reconcile with the separate 24F GYTS record

Common construction fields in the supplied V4 record

Component / parameterWorking valueEvidence status
Fiber typeG.652.DSupplied V4; approved source revision missing
Loose-tube materialPBTSupplied V4; source confirmation required
Central strength memberSteel wireSupplied V4; diameter not supplied
Filler-rod materialPP or PEAlternative material listed; exact quoted configuration TBC
Armor materialCorrugated steel tapeSupplied V4; tape construction/thickness TBC
Outer-sheath materialPESupplied V4; compound, color, UV/fire rating TBC
Outer-sheath diameter8.6 ± 0.3 mmSupplied V4; verify measurement basis and count applicability
Water-blocking systemTBC — source requiredDo not infer from the family name or image labels

Optical Characteristics in the Supplied Record

These are source-listed fiber/cable values, not a complete installed-link loss budget. The V4 record does not provide the controlled test method, acceptance document, or approved revision.

Parameter / conditionWorking valueRelease status
Attenuation at 1310 nm≤ 0.36 dB/kmTBC — source/test basis required
Attenuation at 1550 nm≤ 0.25 dB/kmTBC — source/test basis required
Maximum attenuation difference, 1285–1330 nm≤ 0.03 dB/kmTBC
Maximum attenuation difference, 1525–1575 nm≤ 0.02 dB/kmTBC
Zero-dispersion wavelength1312 ± 10 nmTBC
Zero-dispersion slope≤ 0.090 ps/(nm²·km)TBC
Cable cutoff wavelength≤ 1260 nmTBC; symbol in source requires review
Mode-field diameter at 1310 nm9.2 ± 0.4 μmTBC
Mode-field diameter at 1550 nm10.4 ± 0.5 μmTBC
Effective group index at 1310 nm1.466TBC
Effective group index at 1550 nm1.467TBC
Point discontinuity at 1310 nm≤ 0.05 dBTBC
Point discontinuity at 1550 nm≤ 0.05 dBTBC
Cladding diameter124.8 ± 0.7 μmTBC
Cladding non-circularity≤ 0.7%TBC
Coating diameter254 ± 5 μmTBC
Coating–cladding concentricity error≤ 12.0 μmTBC
Coating non-circularity≤ 6.0%TBC
Core–cladding concentricity error≤ 0.5 μmTBC
Fiber curl radius≥ 4 mTBC

PMD values are intentionally omitted. The V4 editorial note lists three PMD figures without units. Add them only after engineering confirms the parameter names, units, conditions, and approved source.

Mechanical and Environmental Limits

Parameter / conditionWorking valueRelease status
Operation and transport temperature−20 to +70 °CTBC — installation/storage distinctions require confirmation
Source-listed storage or transportation temperature−20 to +70 °CTBC — reconcile with the row above
Minimum bend radius, long term10DTBC — confirm that this means installed/static condition
Minimum bend radius, short term20DTBC — confirm that this means installation/dynamic condition
Tensile load, long term600 NTBC — test method/duration required
Tensile load, short term1200 NTBC — test method/duration required
Crush load, long term800 N/100 mmTBC — test method/duration required
Crush load, short term2000 N/100 mmTBC — test method/duration required

D should be defined in the approved datasheet as the finished cable diameter. With a source-listed diameter of 8.6 mm, do not convert 10D or 20D into absolute millimetres on the page until engineering confirms the nominal/reference diameter and rounding rule.

Application and Compatibility Boundaries

The supplied V4 describes this record for outdoor fiber access and distribution, but it does not establish a route-specific approval.

  • Duct installation: TBC — route suitability and pulling conditions require the approved model document.
  • Aerial installation: TBC — the supplied record does not confirm self-supporting use, messenger support, span, sag, wind, ice, or hardware.
  • Direct burial: TBC — corrugated steel tape alone does not prove direct-burial suitability, water blocking, sheath performance, grounding requirements, or rodent protection.
  • Indoor installation: TBC — PE does not establish the fire/smoke rating required for a building route.
  • Connectors and interfaces: not specified. This is a bulk-cable record; LC, SC, MPO/MTP, polish, polarity, and transceiver compatibility belong to the termination or system design, not this cable-family name.
  • Installed-link acceptance: separate scope. Cable attenuation figures do not include splice, connector, bend, installation, or workmanship losses.

For route-first selection, use the BWNFiber fiber optic cable selection page. For the distinction between armor and installation approval, see the armored vs direct-burial cable guide.

How to Select One Complete Configuration

  1. Choose one fiber count: 8F, 12F, or 24F.
  2. Confirm the exact source revision: request the approved datasheet or drawing that maps the count to tube/filler arrangement and diameter.
  3. Define the route: duct, supported aerial, buried, building entry, or another path; do not approve from the word “outdoor” alone.
  4. Freeze mechanical conditions: pulling tension, crush exposure, installed and installation bend limits, and any span or support conditions.
  5. Confirm environmental and project ratings: temperature, water management, UV, fire/smoke, grounding, chemicals, rodent exposure, and local requirements as applicable.
  6. Define inspection evidence: agree on dimensional, optical, mechanical, marking, packaging, and document checks for the exact quoted configuration.
  7. Lock the purchase description: part/configuration identity, source revision, fiber count and grade, construction, route, lengths, marking, packaging, and approved deviations.

Differences From Related GYTS Records

Related recordOverlapRequired separation
GYTS 16–144F G.652.D steel-tape armored cableShares the GYTS family, G.652.D, 24F option, steel tape, and broad outdoor intentThis page owns only the 8F/12F/24F group with the source-listed 8.6 ± 0.3 mm diameter. The broader page should own multi-count family selection. Live URL and canonical ownership are TBC.
GYTS 24F stranded loose-tube duct cableShares the GYTS family and 24F intentThe separate record lists different dimensions, optical values, mechanical values, and route wording. Engineering must decide whether the two records are distinct models or duplicates before either 24F page is released.
Fiber optic cable categoryOwns broad route and family selectionThis product page should not compete for “fiber optic cable,” “outdoor fiber cable,” or broad “armored fiber cable” intent without the exact configuration qualifier.

Testing and Quality-Control Evidence

TBC — source required. No product-specific inspection plan, test report, certificate, test method, sampling plan, or acceptance record was supplied for this task. Do not add “factory tested,” standards compliance, OTDR results, water-penetration results, or mechanical-test claims without model-specific evidence.

Before order release, request the applicable document set and agree on:

  • exact configuration and source revision;
  • dimensional and construction checks;
  • fiber and cable optical criteria at the specified wavelengths;
  • tensile, crush, bend, and temperature methods and pass criteria, where required;
  • cable marking, length/drum verification, packaging, and lot/drum traceability;
  • any project-specific witness, sample, or first-article requirement.

The installed route requires a separate commissioning plan. See the BWNFiber fiber optic cable testing guide for the distinction between factory cable evidence and field acceptance.

Packaging and Procurement Information

The supplied V4 does not establish standard drum length, reel/drum material, net or gross weight, dimensions, MOQ, price, inventory, lead time, warranty, or destination-specific documents. These fields remain TBC — commercial/source confirmation required.

Required information for an RFQ

RFQ fieldBuyer input
Product referenceGYTS 8F / 12F / 24F 8.6 mm working record
Selected fiber countChoose one: 8F, 12F, or 24F
Fiber gradeG.652.D, subject to approved source confirmation
Installation route and methodState the complete route and support/burial/duct conditions
Mechanical/environmental requirementsTension, crush, bend, temperature, water, UV, fire/smoke, grounding, and other project limits as applicable
Total cable lengthBuyer to specify
Length per drum or rollBuyer to specify
QuantityBuyer to specify
Sheath marking and label languageBuyer to specify
Packaging requirementsBuyer to specify
Delivery destination and target scheduleBuyer to specify
Required documentsDatasheet, drawing, test/inspection evidence, packing data, and destination documents as applicable

Datasheet, Drawing, and Test-Document Area

  • Approved datasheet: TBC — source required
  • Cross-section or construction drawing: TBC — source required
  • Configuration table with revision: TBC — source required
  • Applicable test/inspection documents: TBC — source required
  • Image provenance and technical-match record: TBC — supplied asset reviewed only as a watermarked working diagram
FAQ

Frequently Asked Questions

Which configurations does this page cover?

It covers the supplied working record for 8F, 12F, or 24F G.652.D GYTS cable with a PE sheath and a source-listed 8.6 ± 0.3 mm outer diameter. Select one count for the quotation and confirm it against the approved source revision.

How are the 8F, 12F, and 24F constructions separated?

The V4 table appears to group 8F and 12F as two loose tubes plus three fillers, and 24F as four loose tubes plus one filler. This alignment is not released: the original workbook or approved drawing must confirm it.

Can another 24F GYTS datasheet be substituted?

Not automatically. A separate BWNFiber working record for 24F GYTS lists different dimensions and performance values. Engineering must identify whether the records are distinct constructions or duplicates before either is approved.

Does steel-tape armor prove direct-burial suitability?

No. Armor identifies a protective element, not a complete installation rating. Direct-burial approval requires the exact model’s declared use, water-blocking and sheath construction, mechanical and environmental evidence, and project conditions.

Is this cable self-supporting for aerial installation?

The supplied record does not confirm self-supporting aerial use. Any aerial design must define the support method, span, sag, tension, wind, ice, hardware, clearances, and the approved cable limits.

What bend-radius limits are listed?

The V4 record lists 10D for long-term and 20D for short-term conditions. Engineering must confirm that these correspond to installed/static and installation/dynamic conditions and define D before release.

What attenuation values are listed?

The working record lists ≤ 0.36 dB/km at 1310 nm and ≤ 0.25 dB/km at 1550 nm. These values require source and test-basis confirmation and do not represent a complete installed-link loss allowance.

Are connector options part of this specification?

No connector, polish, polarity, or end condition is specified in the supplied record. Treat this as bulk cable unless a separate approved assembly drawing defines the terminations.

What evidence should be requested before approval?

Request the exact configuration/part identity, controlled datasheet and drawing revisions, construction and dimensional table, declared installation use, applicable optical/mechanical/environmental test criteria, marking, packaging, and approved deviations.

What should be included in the quotation request?

Send the selected count, route and installation method, mechanical and environmental requirements, total length, drum/roll lengths, quantity, marking, packaging, destination, target schedule, and required approval documents.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.