GYTS 72F / 96F G.657.A1 Loose Tube Steel-Tape Armored Fiber Optic Cable
GYTS 72F / 96F G.657.A1 Loose Tube Steel-Tape Armored Fiber Optic Cable for outdoor plant use at 72F / 96F. Confirm model, fiber count and installation method against the source drawing.

Product value summary
This BWNFiber GYTS record covers two high-fiber-count outdoor cable configurations: 72F and 96F, both recorded with G.657.A1 single-mode fiber, PBT loose tubes, a steel-wire central strength member, water-blocking yarn and tape, corrugated steel tape, and a black PE outer sheath. Select one fiber count and keep its tube count and outside diameter together throughout the quotation and approval process.
Specification notice: The supplied F0097 source is marked
NEEDS REVIEW. The visible values below are retained from that record, but ambiguous labels, missing units and unverified application claims are not cleared for publication or purchase-order approval. Final supply must follow an engineer-approved datasheet and drawing for the quoted configuration.Disclaimer: Recorded figures are supplied-source references only and are not a guarantee of the final quoted cable. The approved datasheet, construction drawing, test conditions and purchase specification govern the order.
Quick buyer answer
Choose the 72F configuration when the approved design calls for 72 fibers and the recorded six-tube, 10.5 ± 0.5 mm construction. Choose the 96F configuration when it calls for 96 fibers and the recorded eight-tube, 12.2 ± 0.5 mm construction. Do not combine the tube count or diameter from one column with the fiber count from the other. The installation route, finished-cable bend limits, acceptance tests and required documents still need project-level confirmation.
Primary CTA: Request a 72F / 96F GYTS configuration review
Send the required fiber count, route, total length, length per drum, quantity, marking, destination and required approval documents. BWNFiber should return either a configuration confirmation or a list of fields that still need engineering review.
Key configuration features
- Two recorded fiber counts: 72F and 96F.
- Recorded fiber grade: ITU-T G.657.A1.
- Loose-tube construction: PBT tubes with count-specific tube quantities.
- Central strength member: steel wire.
- Moisture-barrier materials: water-blocking yarn and water-blocking tape.
- Armor: corrugated steel tape.
- Outer sheath: black PE.
- Procurement control: approve the fiber count, tube count and cable diameter as one configuration.
F and 96F configuration map
| Approval field | 72F configuration | 96F configuration | Evidence status |
|---|---|---|---|
| Fiber count | 72F | 96F | A |
| Fiber grade | G.657.A1 | G.657.A1 | A |
| Number of loose tubes | 6 | 8 | A, pending original-row alignment check |
| Loose-tube diameter | 2.0 ± 0.1 mm | 2.0 ± 0.1 mm | A |
| Loose-tube material | PBT | PBT | A |
| Central strength member | Steel wire | Steel wire | A |
| Moisture-barrier materials | Water-blocking yarn and water-blocking tape | Water-blocking yarn and water-blocking tape | A |
| Armor | Corrugated steel tape | Corrugated steel tape | A |
| Outer sheath | Black PE | Black PE | A |
| Recorded outer diameter | 10.5 ± 0.5 mm | 12.2 ± 0.5 mm | A, pending original-row alignment check |
Optical characteristics retained from the supplied record
| Parameter / condition | Recorded value | Publication status |
|---|---|---|
| Attenuation at 1310 nm | ≤0.4 dB/km | A; confirm test method and approved datasheet |
| Attenuation at 1550 nm | ≤0.3 dB/km | A; confirm test method and approved datasheet |
| Maximum attenuation difference, 1285–1330 nm | ≤0.03 dB/km | A; confirm terminology and method |
| Maximum attenuation difference, 1525–1575 nm | ≤0.02 dB/km | A; confirm terminology and method |
| Zero-dispersion wavelength | 1300–1324 nm | A |
| Zero-dispersion slope | ≤0.092 ps/(nm²·km) | A; typography normalized, source to be checked |
| Cable cut-off wavelength | ≤1260 nm | A; source symbol requires review |
| Effective group index at 1310 nm | 1.466 | A |
| Effective group index at 1550 nm | 1.467 | A |
| Point discontinuity at 1310 nm | ≤0.05 dB | A; confirm measurement method |
| Point discontinuity at 1550 nm | ≤0.05 dB | A; confirm measurement method |
| Cladding diameter | 124.8 ± 0.7 μm | A |
| Cladding non-circularity | ≤0.7% | A |
| Coating diameter | 245 ± 5 μm | A |
| Coating-cladding concentricity error | ≤12.0 μm | A |
| Coating non-circularity | ≤6.0% | A |
| Core-cladding concentricity error | ≤0.5 μm | A |
| Curl radius | ≥4 m | A |
The source also contains PMD values without units and mode-field-diameter values whose recorded unit is nm. Those fields are intentionally excluded from this draft until BWNFiber corrects or confirms the source.
Mechanical and environmental record
| Parameter | Recorded value | Publication status |
|---|---|---|
| Storage or transportation temperature | -20°C to +70°C | A |
| Operation and transport temperature | -20°C to +70°C | A; confirm whether installation has a separate range |
| Long-term tensile strength | 1000 N | A; confirm source header alignment |
| Short-term tensile strength | 2000 N | A; confirm source header alignment |
| Long-term crush load | 1000 N/100 mm | A; short-term value not supplied |
| Finished-cable bend radius | TBC — source required | Source currently maps short term 10D and long term 20D; labels require engineering confirmation before use |
D must be defined as the approved finished-cable outside diameter in the final datasheet. The G.657.A1 fiber designation does not replace the finished-cable bend limit.
Interfaces and termination scope
The supplied record defines a bulk outdoor fiber-optic cable. It does not define connector types, polish, connector count, breakout legs, factory termination or compatibility with a named enclosure or transceiver. If the project requires a pre-terminated assembly, route that requirement to a separate assembly specification rather than adding connector claims to this cable page.
Application and compatibility conditions
The supplied record identifies the product for outdoor fiber access and distribution. It does not, by itself, approve every aerial, duct or direct-burial route.
Before approving the model, confirm:
- the declared installation method for the exact quoted construction;
- pulling tension, crush exposure and finished-cable bend limits;
- duct, support, grounding and moisture-management conditions;
- local project requirements for sheath, fire behavior, UV exposure and documentation;
- the exact closure, splice, termination and reserve-length plan.
Corrugated steel tape is a construction attribute. It is not standalone evidence of direct-burial approval, rodent resistance, UV performance or any certification.
How to select the correct configuration
- Choose one fiber count: 72F or 96F.
- Lock its mapped construction: retain the corresponding tube count and recorded outer diameter.
- Confirm the route: state outdoor pathway, installation method, pulling plan, mechanical exposure and temperature conditions.
- Confirm the cable limits: approve tensile, crush, bend and temperature values against the corrected datasheet.
- Define acceptance evidence: list the drawing, datasheet, test record, marking sample and inspection documents required with the quotation or order.
- Approve the commercial configuration: total length, length per drum, quantity, marking and delivery destination.
Differences from related BWNFiber records
| Related record | Distinguishing scope | Do not combine |
|---|---|---|
| GYTS 16–144F G.652.D | Broad count range with G.652.D fiber | Do not use its fiber grade, dimensions or mechanical values for this G.657.A1 page |
| GYTS 8F / 12F / 24F, 8.6 mm | Lower-count GYTS configuration | Do not transfer its 8.6 mm diameter or count options |
| GYTS 24F duct cable | 24F duct-focused record with a different table | Do not treat it as a 72F / 96F variant |
| Fiber Optic Cable category | Family discovery and route-based selection | Category owns broad fiber optic cable and outdoor fiber optic cable intent |
Testing, quality control and approval documents
The supplied material does not prove a production test process or the documents included with an order. Before publication or quotation approval, BWNFiber must confirm which of the following are available for this exact model and revision:
| Requested evidence | Current status |
|---|---|
| Approved product datasheet | TBC — source required |
| Count-specific construction drawing | TBC — source required |
| Fiber-grade declaration / traceability | TBC — source required |
| Optical test method and factory-length results | TBC — source required |
| Mechanical test method and acceptance limits | TBC — source required |
| Drum / lot identification and cable marking sample | TBC — source required |
| Certificate of conformity or project-required compliance documents | TBC — source required |
Do not describe a requested document as a standard deliverable until the product owner confirms it.
Packaging and procurement information
Provide these inputs for quotation:
- selected configuration: 72F or 96F;
- G.657.A1 fiber requirement;
- total cable length and required length per drum;
- quantity;
- installation route and method;
- cable marking text;
- delivery destination;
- required datasheet, drawing, test and compliance documents;
- requested inspection, sample or approval stage, if any.
Packaging type, drum dimensions, MOQ, stock, price, lead time, warranty and delivery commitment are TBC — source required.
Datasheet, drawing and test-report area
- Product datasheet: TBC — source required
- 72F / 96F construction drawing: TBC — source required
- Optical test record: TBC — source required
- Mechanical / environmental qualification evidence: TBC — source required
- Cable marking and packaging specification: TBC — source required
Product visual
Caption: Supplied labeled GYTS construction illustration. Confirm the drawing revision and whether it exactly represents both the 72F and 96F production configurations before publication.
Final RFQ call to action
Request a 72F / 96F GYTS configuration review
Send BWNFiber the selected fiber count, route, length schedule, quantity, marking and required approval documents. Ask the reviewer to confirm the count-specific tube quantity and diameter, correct the bend-radius labels, add the missing units and identify the documents available for the quoted model.
Secondary action: Request the corrected datasheet and construction drawing before order approval.
Frequently asked questions
What is the difference between the 72F and 96F configurations?
The supplied record maps 72F to six loose tubes and a 10.5 ± 0.5 mm outside diameter, and 96F to eight loose tubes and a 12.2 ± 0.5 mm outside diameter. Engineering must verify this source-column alignment before publication. Keep the selected count, tube quantity and diameter together in the quotation.
Does G.657.A1 define the finished cable bend radius?
No. G.657.A1 defines a bend-insensitive single-mode fiber category. The finished cable also has a construction-specific bend limit. The supplied source has an unresolved short-term / long-term label pairing, so the finished-cable value remains TBC pending engineering confirmation.
Is this a connectorized cable assembly?
Not in the supplied record. The current scope is bulk cable; no connector, polish, breakout or termination is defined. Specify a separate pre-terminated assembly if the project needs factory-installed ends.
Can this cable be approved for aerial, duct or direct-burial installation?
Not from the family name or armor alone. The source states outdoor access and distribution, but the exact installation method must be confirmed against the approved construction, route conditions and project requirements.
What optical attenuation values are recorded?
The supplied record lists ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm. Confirm the test method, factory-length record and applicable acceptance conditions before using these values in a purchase specification or link budget.
What must be confirmed before requesting a quotation?
State 72F or 96F, the G.657.A1 requirement, route and installation method, total length, length per drum, quantity, marking and destination. Also list every required drawing, datasheet, test record and compliance document so the technical and commercial offers refer to the same configuration.