GYTS 72F / 96F G.657.A1 Loose Tube Steel-Tape Armored Fiber Optic Cable

GYTS 72F / 96F G.657.A1 Loose Tube Steel-Tape Armored Fiber Optic Cable for outdoor plant use at 72F / 96F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

GYTS

Product value summary

This BWNFiber GYTS record covers two high-fiber-count outdoor cable configurations: 72F and 96F, both recorded with G.657.A1 single-mode fiber, PBT loose tubes, a steel-wire central strength member, water-blocking yarn and tape, corrugated steel tape, and a black PE outer sheath. Select one fiber count and keep its tube count and outside diameter together throughout the quotation and approval process.

Specification notice: The supplied F0097 source is marked NEEDS REVIEW. The visible values below are retained from that record, but ambiguous labels, missing units and unverified application claims are not cleared for publication or purchase-order approval. Final supply must follow an engineer-approved datasheet and drawing for the quoted configuration.

Disclaimer: Recorded figures are supplied-source references only and are not a guarantee of the final quoted cable. The approved datasheet, construction drawing, test conditions and purchase specification govern the order.

Quick buyer answer

Choose the 72F configuration when the approved design calls for 72 fibers and the recorded six-tube, 10.5 ± 0.5 mm construction. Choose the 96F configuration when it calls for 96 fibers and the recorded eight-tube, 12.2 ± 0.5 mm construction. Do not combine the tube count or diameter from one column with the fiber count from the other. The installation route, finished-cable bend limits, acceptance tests and required documents still need project-level confirmation.

Primary CTA: Request a 72F / 96F GYTS configuration review
Send the required fiber count, route, total length, length per drum, quantity, marking, destination and required approval documents. BWNFiber should return either a configuration confirmation or a list of fields that still need engineering review.

Key configuration features

  • Two recorded fiber counts: 72F and 96F.
  • Recorded fiber grade: ITU-T G.657.A1.
  • Loose-tube construction: PBT tubes with count-specific tube quantities.
  • Central strength member: steel wire.
  • Moisture-barrier materials: water-blocking yarn and water-blocking tape.
  • Armor: corrugated steel tape.
  • Outer sheath: black PE.
  • Procurement control: approve the fiber count, tube count and cable diameter as one configuration.

F and 96F configuration map

Approval field72F configuration96F configurationEvidence status
Fiber count72F96FA
Fiber gradeG.657.A1G.657.A1A
Number of loose tubes68A, pending original-row alignment check
Loose-tube diameter2.0 ± 0.1 mm2.0 ± 0.1 mmA
Loose-tube materialPBTPBTA
Central strength memberSteel wireSteel wireA
Moisture-barrier materialsWater-blocking yarn and water-blocking tapeWater-blocking yarn and water-blocking tapeA
ArmorCorrugated steel tapeCorrugated steel tapeA
Outer sheathBlack PEBlack PEA
Recorded outer diameter10.5 ± 0.5 mm12.2 ± 0.5 mmA, pending original-row alignment check

Optical characteristics retained from the supplied record

Parameter / conditionRecorded valuePublication status
Attenuation at 1310 nm≤0.4 dB/kmA; confirm test method and approved datasheet
Attenuation at 1550 nm≤0.3 dB/kmA; confirm test method and approved datasheet
Maximum attenuation difference, 1285–1330 nm≤0.03 dB/kmA; confirm terminology and method
Maximum attenuation difference, 1525–1575 nm≤0.02 dB/kmA; confirm terminology and method
Zero-dispersion wavelength1300–1324 nmA
Zero-dispersion slope≤0.092 ps/(nm²·km)A; typography normalized, source to be checked
Cable cut-off wavelength≤1260 nmA; source symbol requires review
Effective group index at 1310 nm1.466A
Effective group index at 1550 nm1.467A
Point discontinuity at 1310 nm≤0.05 dBA; confirm measurement method
Point discontinuity at 1550 nm≤0.05 dBA; confirm measurement method
Cladding diameter124.8 ± 0.7 μmA
Cladding non-circularity≤0.7%A
Coating diameter245 ± 5 μmA
Coating-cladding concentricity error≤12.0 μmA
Coating non-circularity≤6.0%A
Core-cladding concentricity error≤0.5 μmA
Curl radius≥4 mA

The source also contains PMD values without units and mode-field-diameter values whose recorded unit is nm. Those fields are intentionally excluded from this draft until BWNFiber corrects or confirms the source.

Mechanical and environmental record

ParameterRecorded valuePublication status
Storage or transportation temperature-20°C to +70°CA
Operation and transport temperature-20°C to +70°CA; confirm whether installation has a separate range
Long-term tensile strength1000 NA; confirm source header alignment
Short-term tensile strength2000 NA; confirm source header alignment
Long-term crush load1000 N/100 mmA; short-term value not supplied
Finished-cable bend radiusTBC — source requiredSource currently maps short term 10D and long term 20D; labels require engineering confirmation before use

D must be defined as the approved finished-cable outside diameter in the final datasheet. The G.657.A1 fiber designation does not replace the finished-cable bend limit.

Interfaces and termination scope

The supplied record defines a bulk outdoor fiber-optic cable. It does not define connector types, polish, connector count, breakout legs, factory termination or compatibility with a named enclosure or transceiver. If the project requires a pre-terminated assembly, route that requirement to a separate assembly specification rather than adding connector claims to this cable page.

Application and compatibility conditions

The supplied record identifies the product for outdoor fiber access and distribution. It does not, by itself, approve every aerial, duct or direct-burial route.

Before approving the model, confirm:

  1. the declared installation method for the exact quoted construction;
  2. pulling tension, crush exposure and finished-cable bend limits;
  3. duct, support, grounding and moisture-management conditions;
  4. local project requirements for sheath, fire behavior, UV exposure and documentation;
  5. the exact closure, splice, termination and reserve-length plan.

Corrugated steel tape is a construction attribute. It is not standalone evidence of direct-burial approval, rodent resistance, UV performance or any certification.

How to select the correct configuration

  1. Choose one fiber count: 72F or 96F.
  2. Lock its mapped construction: retain the corresponding tube count and recorded outer diameter.
  3. Confirm the route: state outdoor pathway, installation method, pulling plan, mechanical exposure and temperature conditions.
  4. Confirm the cable limits: approve tensile, crush, bend and temperature values against the corrected datasheet.
  5. Define acceptance evidence: list the drawing, datasheet, test record, marking sample and inspection documents required with the quotation or order.
  6. Approve the commercial configuration: total length, length per drum, quantity, marking and delivery destination.

Differences from related BWNFiber records

Related recordDistinguishing scopeDo not combine
GYTS 16–144F G.652.DBroad count range with G.652.D fiberDo not use its fiber grade, dimensions or mechanical values for this G.657.A1 page
GYTS 8F / 12F / 24F, 8.6 mmLower-count GYTS configurationDo not transfer its 8.6 mm diameter or count options
GYTS 24F duct cable24F duct-focused record with a different tableDo not treat it as a 72F / 96F variant
Fiber Optic Cable categoryFamily discovery and route-based selectionCategory owns broad fiber optic cable and outdoor fiber optic cable intent

Testing, quality control and approval documents

The supplied material does not prove a production test process or the documents included with an order. Before publication or quotation approval, BWNFiber must confirm which of the following are available for this exact model and revision:

Requested evidenceCurrent status
Approved product datasheetTBC — source required
Count-specific construction drawingTBC — source required
Fiber-grade declaration / traceabilityTBC — source required
Optical test method and factory-length resultsTBC — source required
Mechanical test method and acceptance limitsTBC — source required
Drum / lot identification and cable marking sampleTBC — source required
Certificate of conformity or project-required compliance documentsTBC — source required

Do not describe a requested document as a standard deliverable until the product owner confirms it.

Packaging and procurement information

Provide these inputs for quotation:

  • selected configuration: 72F or 96F;
  • G.657.A1 fiber requirement;
  • total cable length and required length per drum;
  • quantity;
  • installation route and method;
  • cable marking text;
  • delivery destination;
  • required datasheet, drawing, test and compliance documents;
  • requested inspection, sample or approval stage, if any.

Packaging type, drum dimensions, MOQ, stock, price, lead time, warranty and delivery commitment are TBC — source required.

Datasheet, drawing and test-report area

  • Product datasheet: TBC — source required
  • 72F / 96F construction drawing: TBC — source required
  • Optical test record: TBC — source required
  • Mechanical / environmental qualification evidence: TBC — source required
  • Cable marking and packaging specification: TBC — source required

Product visual

Caption: Supplied labeled GYTS construction illustration. Confirm the drawing revision and whether it exactly represents both the 72F and 96F production configurations before publication.

Final RFQ call to action

Request a 72F / 96F GYTS configuration review

Send BWNFiber the selected fiber count, route, length schedule, quantity, marking and required approval documents. Ask the reviewer to confirm the count-specific tube quantity and diameter, correct the bend-radius labels, add the missing units and identify the documents available for the quoted model.

Secondary action: Request the corrected datasheet and construction drawing before order approval.


FAQ

Frequently asked questions

What is the difference between the 72F and 96F configurations?

The supplied record maps 72F to six loose tubes and a 10.5 ± 0.5 mm outside diameter, and 96F to eight loose tubes and a 12.2 ± 0.5 mm outside diameter. Engineering must verify this source-column alignment before publication. Keep the selected count, tube quantity and diameter together in the quotation.

Does G.657.A1 define the finished cable bend radius?

No. G.657.A1 defines a bend-insensitive single-mode fiber category. The finished cable also has a construction-specific bend limit. The supplied source has an unresolved short-term / long-term label pairing, so the finished-cable value remains TBC pending engineering confirmation.

Is this a connectorized cable assembly?

Not in the supplied record. The current scope is bulk cable; no connector, polish, breakout or termination is defined. Specify a separate pre-terminated assembly if the project needs factory-installed ends.

Can this cable be approved for aerial, duct or direct-burial installation?

Not from the family name or armor alone. The source states outdoor access and distribution, but the exact installation method must be confirmed against the approved construction, route conditions and project requirements.

What optical attenuation values are recorded?

The supplied record lists ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm. Confirm the test method, factory-length record and applicable acceptance conditions before using these values in a purchase specification or link budget.

What must be confirmed before requesting a quotation?

State 72F or 96F, the G.657.A1 requirement, route and installation method, total length, length per drum, quantity, marking and destination. Also list every required drawing, datasheet, test record and compliance document so the technical and commercial offers refer to the same configuration.