Armored / Direct Burial Cable

GYTS 2F 8.5mm G.652.D Steel-Tape Armored Duct Fiber Optic Cable

GYTS 2F 8.5mm G.652.D Steel-Tape Armored Duct Fiber Optic Cable with documented armored construction at 2F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

GYTS

Product summary

This page covers one configuration: GYTS, 2 fibers (2F), G.652.D, 8.5 mm nominal cable diameter, for duct fiber routes. Use the exact configuration in the quotation request. A different fiber count, diameter, fiber grade, construction or route approval is a separate configuration and must not be substituted without review.

Release note: The supplied P088 source record is marked for engineering review because the multi-column source table requires alignment confirmation. Values below remain subject to that confirmation before publication.

Specification notice: Figures in this draft reproduce the supplied P088 product record and require engineering confirmation before approval. They are not a guarantee of installed-link performance, route approval, delivery, price, stock or certification.

Key features

  • Fiber count: 2F
  • Fiber type: G.652.D
  • Nominal cable diameter: 8.5 mm
  • Declared application in the supplied record: duct installation
  • Supplied construction entries: corrugated steel tape armor and PE outer sheath — TBC — source-row confirmation required

Configuration at a glance

FieldSelected configuration
Cable familyGYTS
Fiber count2F
Fiber typeG.652.D
Nominal cable diameter8.5 mm
Declared routeDuct installation
Connector/interfaceNot applicable to the supplied bulk cable record; TBC — source required
Other fiber countsSeparate configurations; do not combine rows

Is this cable intended for duct installation?

The supplied product record identifies this configuration for duct fiber routes. It does not, by itself, approve aerial or direct-burial installation. Confirm the selected model’s declared route, water-management design, pulling conditions, bend limits, and project requirements before approval.

Technical specifications

Cable and mechanical data

ParameterSupplied P088 valueRelease status
Fibers per tube / count2Engineering confirmation required
Tubes & fillers / count1 & 4Engineering confirmation required
Loose-tube size1.6 mmEngineering confirmation required
Steel wire size1.2 mmEngineering confirmation required
Sheath thickness1.5 mmEngineering confirmation required
Cable diameter8.5 mmNominal; confirm source row
Cable weight70 kg/kmEngineering confirmation required
Armor materialCorrugated steel tapeEngineering confirmation required
Outer sheath materialPEEngineering confirmation required
Tensile, long/short term300 / 1000 NConfirm order and test basis
Crush, long/short term300 / 1000 N/100 mmConfirm unit, order and test basis
Operating temperature-30°C to +60°CEngineering confirmation required
Installation temperature-30°C to +60°CEngineering confirmation required
Storage temperature-40°C to +70°CEngineering confirmation required

The table is reproduced from the supplied product record; it is not a substitute for a signed datasheet or controlled test report. Confirm the test standard, specimen, duration, measurement and acceptance criteria before comparing this cable with another model.

Optical characteristics

Parameter / conditionSupplied valueRelease status
Mode-field diameter at 1310 nm9.2 ± 0.4 μmConfirm source/test basis
Cladding diameter125 ± 1 μmConfirm source/test basis
Core concentricity error≤0.6 μmConfirm source/test basis
Cladding non-circularity≤1.0%Confirm source/test basis
Cable cut-off wavelength, λcc≤1260 nmConfirm source/test basis
Fiber cut-off wavelength, λc1180–1330 nmConfirm source/test basis
Primary coating, excluding color layer245 ± 10 μmConfirm source/test basis
Primary coating, including color layer250 ± 15 μmConfirm source/test basis
Coating–cladding concentricity error≤12.5 μmConfirm source/test basis
Fiber curl radius≥4 mConfirm source/test basis
Attenuation at 1310 nm≤0.36 dB/km (max.)Confirm whether fiber or cable value
Attenuation at 1550 nm≤0.21 dB/km (max.)Confirm whether fiber or cable value
Chromatic dispersion, 1288–1339 nm≤3.5 ps/nm·kmConfirm source/test basis
Chromatic dispersion at 1550 nm≤17 ps/nm·kmConfirm source/test basis
Zero-dispersion wavelength1300–1324 nmConfirm source/test basis
Zero-dispersion slope≤0.092 ps/nm²·kmConfirm source/test basis
Macro-bending loss, Φ=60 mm, 100 turns at 1550 nm≤0.1 dBConfirm test method and finished-cable applicability

These values are not a complete installed-link loss allowance. Connectors, splices, patching, route length and system margin must be assessed separately.

Fiber type and configuration boundaries

G.652.D is the supplied fiber designation for this configuration. Do not infer G.657 bend-insensitive performance, multimode compatibility, transmission reach, connector compatibility, or standards compliance from the GYTS family name. Those fields require a product datasheet or project approval.

How to select and verify the model

  1. Confirm the route is a duct route and record any transition to aerial, indoor or direct-burial sections.
  2. Confirm the exact identity: GYTS / 2F / G.652.D / 8.5 mm nominal.
  3. Confirm the construction rows, mechanical units, temperature fields and optical test basis against the controlled source.
  4. Confirm pulling tension, crush, bend and duct occupancy requirements for the project.
  5. Request the approved datasheet, drawing and test documentation if required by the acceptance plan.
  6. Put the total length, drum or roll length, quantity, cable marking and destination in the RFQ.

Differences from related products

  • GYTS 48F or other higher-count GYTS: a different fiber-count and dimensional configuration; do not combine its table rows with this 2F page.
  • Central loose-tube armored cable: a different construction family and should be compared by structure, route, count, diameter and verified mechanical data.
  • Direct-burial cable: “armored” describes construction; direct burial describes an installation method. Direct-burial approval is not established by this page.
  • Indoor or connectorized cable: this is a bulk outdoor cable record, not a terminated patch cord or indoor fire-rated assembly.

For broader route selection, see BWNFiber’s fiber optic cable selection guide. For a different central-loose-tube construction, compare the 2–24F central loose-tube outdoor armored cable. For test-method context, read armored fiber cable mechanical ratings. Use the fiber optic cable category to review other route and count families.

Use cases

The supplied record supports duct fiber routes. Project-specific use remains subject to route, installation loads, environmental conditions, applicable approvals and the selected model’s controlled documentation.

Testing and quality-control information

The supplied P088 record provides specification values but does not provide a named test standard, test equipment, sample size, duration, calibration record, inspection plan or signed report. Add those items only when BWNFiber supplies the controlled documents.

Packaging and procurement

Standard drum or roll length, packaging method, MOQ, price, stock, lead time, warranty and delivery terms are TBC — source required. Request the required length per drum or roll rather than assuming a standard reel length.

RFQ checklist

Send the following information so the quoted configuration can be checked:

  • Product: GYTS 2F 8.5 mm G.652.D Steel-Tape Armored Duct Fiber Optic Cable
  • Fiber count and grade: 2F, G.652.D
  • Nominal cable diameter: 8.5 mm
  • Total cable length
  • Required length per drum or roll
  • Quantity
  • Cable marking text
  • Delivery destination
  • Duct route and any special pulling, bend, temperature or documentation requirements
  • Required datasheet, drawing or test-report package, if applicable

Documents

  • Datasheet: TBC — approved source required
  • Construction drawing: TBC — approved source required
  • Test report: TBC — approved source required

CTA

Request a configuration review and quotation. Include the RFQ fields above and ask BWNFiber to confirm the controlled source, construction table, documentation package and route suitability for the proposed project.

FAQ

FAQ

Which fiber count does this GYTS page cover?

This page covers the 2F G.652.D configuration. A different fiber count is a separate configuration and must be quoted separately.

What identifies this exact configuration?

Keep all four identifiers together in the request: GYTS, 2F, G.652.D and 8.5 mm nominal diameter. This reduces the risk of substituting a broader GYTS family row.

Is the cable approved for direct burial or aerial installation?

That approval is not established by the supplied P088 record. Confirm the exact model’s declared route and controlled documentation before using it outside the stated duct scope.

What attenuation values are listed?

The supplied record lists a maximum of 0.36 dB/km at 1310 nm and 0.21 dB/km at 1550 nm. Confirm whether the controlled document defines each value at fiber or finished-cable level; neither value is a complete installed-link budget.

What mechanical values are listed?

The supplied record lists 300/1000 N for long/short-term tensile and 300/1000 N/100 mm for long/short-term crush. Confirm row alignment, units, test method and acceptance criteria before approval.

What should I include in an RFQ?

State the exact configuration, total length, length per drum or roll, quantity, marking text and delivery destination. Include route and documentation requirements when they affect acceptance.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.