Outdoor Fiber Cable

GYTS 24F Stranded Loose Tube Duct Fiber Optic Cable

GYTS 24F Stranded Loose Tube Duct Fiber Optic Cable for outdoor plant use at 24F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

GYTS

Buyer-oriented summary

This working record describes a 24-fiber GYTS loose-tube cable proposed for duct routes. The supplied table lists six fibers per tube, four tubes plus one filler, a black PE sheath, an 8.5 mm cable diameter and a 69 kg/km cable weight. These values are not released specifications: BWNFiber must first reconcile this record with the separate 24F GYTS construction and issue the applicable controlled datasheet or drawing.

Working configuration table

FieldWorking value from P178Release status
Product familyGYTSTBC — confirm product master identity
Fiber count24FTBC — confirm exact configuration
Fibers per tube6TBC — approved drawing/source row required
Tubes / fillers4 / 1TBC — approved drawing/source row required
Loose-tube diameter1.6 mmTBC — tolerance and measurement basis required
Coated steel-wire diameter1.2 mmTBC — confirm component and measurement basis
Central strength memberTBC — source requiredDo not label steel tape as the strength member
ArmorCorrugated steel tape — TBCBOM/drawing required
Outer sheathBlack PE — TBCCompound, rating and color approval required
Cable diameter8.5 mmTBC — nominal/tolerance basis required
Cable weight69 kg/kmTBC — nominal/tolerance basis required
Tensile load1500 N short term / 600 N long termTBC — method and duration required
Crush resistanceTBC — source requiredSupplied 1000/3000 short/long mapping must be reconciled
Fiber gradeTBC — source requiredDo not infer G.652.D from the family page
Installation routeDuct — conditionalApproved route and pulling conditions required

Optical working values

The supplied P178 record contains the values below. They are preserved for engineering reconciliation only and must not be represented as approved performance until the fiber grade, source revision and test basis are confirmed.

Parameter / conditionWorking valueStatus
Mode-field diameter at 1310 nm9.2 ± 0.4 μmTBC
Cladding diameter125 ± 1 μmTBC
Core concentricity error≤ 0.6 μmTBC
Cladding non-circularity≤ 1.0%TBC
Cable cutoff wavelength≤ 1260 nmTBC
Fiber cutoff wavelength1180–1330 nmTBC
Primary coating diameter, excluding color layer245 ± 10 μmTBC
Primary coating diameter, including color layer250 ± 15 μmTBC
Coating–cladding concentricity error≤ 12.5 μmTBC
Fiber curl radius≥ 4 mTBC
Attenuation at 1310 nm≤ 0.36 dB/km maximumTBC; not a link budget
Attenuation at 1550 nm≤ 0.21 dB/km maximumTBC; not a link budget
Chromatic dispersion, 1288–1339 nm≤ 3.5 ps/(nm·km)TBC
Chromatic dispersion at 1550 nm≤ 17 ps/(nm·km)TBC
Zero-dispersion wavelength1300–1324 nmTBC
Zero-dispersion slope≤ 0.092 ps/(nm²·km)TBC
Dispersion-mode-bias field in V40.5 ps/km1/2Blocked — parameter name and unit require correction

Environmental working values

ParameterWorking valueStatus
Operating temperature−30 to +60 °CTBC — qualification source required
Installation temperature−30 to +60 °CTBC — handling approval required
Storage temperature−40 to +70 °CTBC — qualification source required
Fiber macro-bend test≤ 0.1 dB at 1550 nm, 60 mm diameter, 100 turnsTBC — not a finished-cable bend-radius specification

Selection and RFQ steps

  1. Reference the confirmed GYTS part/configuration ID and controlled revision.
  2. State the route as duct and provide duct size, occupancy, length, bends, pulling method and environmental conditions where relevant.
  3. Confirm the fiber grade, fiber count, tube/filler map, central member, armor and sheath construction.
  4. Confirm finished-cable diameter, mass, tensile/crush criteria and installation/installed bend limits with their test basis.
  5. Specify total length, length per drum, quantity, sheath marking, label language, packaging, destination and target schedule.
  6. List required documents: approved datasheet, construction drawing, applicable inspection/test evidence, packing data and approved deviations.

Merge-ready CTA

Request the controlled 24F GYTS configuration and quotation. Send the duct route, required length, drum lengths, quantity, marking, destination and approval-document list. Ask BWNFiber to identify the applicable part/configuration revision and close every TBC field before order approval.

FAQ

Merge-ready FAQs

Is this P178 record the same as BWNFiber’s other 24F GYTS configuration?

That has not been established. The two working records list different dimensions and performance values. BWNFiber Product/Engineering must map both records to part numbers, BOMs and controlled revisions before either set of values is used for quotation or publication.

Can the 8.5 mm and 8.6 mm GYTS specifications be combined?

No. A small diameter difference may represent a tolerance, revision, extraction issue or genuinely different construction. Do not combine values until the controlled drawings and product identities show how the records relate.

Is corrugated steel tape the central strength member?

The supplied P178 table is ambiguous. The diagram labels steel wire and steel tape separately, so the approved BOM or drawing must identify the central strength member and armor as separate components.

What crush resistance applies?

TBC. The V4 row lists 1000/3000 N/100 mm for short-/long-term conditions, but the mapping requires Quality review. Do not quote either value until the source row and test basis are confirmed.

Is the cable approved for aerial installation?

Not from the supplied evidence. The page title and introduction focus on duct use, while one table mentions duct/aerial. Aerial use requires an approved support method and applicable mechanical/environmental design; self-supporting use must never be inferred.

What fiber grade does this record use?

TBC — source required. The optical values alone do not authorize labeling this record G.652.D or another specific grade.

Are the attenuation figures a complete link-loss budget?

No. Working cable/fiber attenuation values do not include installed length variance, splices, connectors, bends, workmanship or design margin. Link acceptance requires a separate project method and budget.

What should be sent for a quotation?

Send the confirmed configuration ID, route, environmental and mechanical requirements, total and drum lengths, quantity, marking, packaging, destination, schedule and required approval documents.