GYTS
GYTS 16–144F G.652.D Loose Tube Steel-Tape Armored Fiber Optic Cable
GYTS 16–144F G.652.D Loose Tube Steel-Tape Armored Fiber Optic Cable for outdoor plant use at 16F / 24F / 32F / 48F / 72F / 96F / 144F. Confirm model, fiber count and installation method against the source drawing.

Product summary
This P014 product record covers a GYTS loose-tube outdoor fiber optic cable family with G.652.D fiber, corrugated steel-tape armor, a steel-wire central strength member, and a black PE outer sheath. The working record lists 16F, 24F, 32F, 48F, 72F, 96F, and 144F options.
The controlled source table is still under review. Confirm the selected fiber count, count-specific cable dimensions, mechanical limits, route conditions, and document revision before purchase or installation. Do not combine a value from one count or related GYTS page with another configuration.
Buyer answer: Send the required fiber count, route and support method, total length, drum lengths, quantity, cable marking, destination, and required documents. Ask BWNFiber to return the controlled P014 datasheet/drawing, the selected configuration, applicable test-document list, and quotation.
Configuration at a glance
| Field | Working P014 record | Release status |
|---|---|---|
| Model / product family | GYTS / P014 | First-party working record; product owner confirmation required |
| Fiber counts | 16F / 24F / 32F / 48F / 72F / 96F / 144F | First-party working record; count-specific mapping required |
| Fiber type | G.652.D | TBC — controlled source required |
| Construction | Loose tube | TBC — controlled drawing required |
| Central strength member | Steel wire | TBC — controlled drawing required |
| Moisture-barrier record | Water-blocking yarn and gel | TBC — exact construction and terminology required |
| Armor | Corrugated steel tape | TBC — controlled drawing required |
| Outer sheath | Black PE | TBC — material grade and thickness not confirmed |
| Intended installation | TBC — source required | Do not infer duct, aerial, direct burial, anti-rodent, UV, or flame rating from the family name |
Cable construction
The supplied working record describes PBT loose tubes around a steel-wire central strength member, water-blocking yarn and gel, corrugated steel-tape armor, and a black PE outer sheath. These elements identify the intended construction family, but the current product folder does not contain the controlled Excel/drawing needed to approve the layer sequence, dimensions, count-specific tube/filler plan, or material grades.
Construction approval checklist
- Confirm one drawing revision for P014.
- Confirm the number of loose tubes and fibers per tube for each count.
- Confirm filler elements, layer sequence, and central-member coating, if any.
- Confirm whether the cable is gel-filled, uses water-blocking yarn, or uses both, and where each element is located.
- Confirm steel-tape type, overlap/bonding construction, and PE material grade only when the drawing states them.
- Confirm the exact route and environmental qualification separately from the construction name.
Technical specifications pending approval
Finished-cable mechanical and environmental fields
| Parameter | Working record | Release status / action |
|---|---|---|
| Storage or transportation temperature | −20°C to +70°C | TBC — the V4 record uses overlapping temperature labels; confirm operation, installation, storage, and transportation separately |
| Minimum bend radius, long term | 20D in the V4 mechanical table | Blocked: conflicts with an anonymous Short term 10D row; confirm which condition is installed/static and which is installation/dynamic |
| Tensile strength, long term | 800 N in the V4 mechanical table | TBC — confirm test method and corresponding short-term value |
| Crush load, long term | 1000 N/100 mm in the V4 mechanical table | TBC — confirm test method and corresponding short-term value |
| Anonymous V4 row | Short term: 10D | do not use for order release until the missing parameter name is restored |
| Anonymous V4 row | Short term: 1500 | do not use for order release until parameter and unit are restored |
| Anonymous V4 row | Short term: 2000 | do not use for order release until parameter and unit are restored |
| Cable diameter / weight by fiber count | Not available in the supplied review folder | TBC — source required |
D must be defined as the approved finished-cable outside diameter before a bend-radius statement is released. Do not treat a bend limit, tensile value, or steel-tape layer as proof that the cable is suitable for a specific route.
Optical values listed in the working record
| Parameter / condition | Working value | Release status |
|---|---|---|
| Attenuation at 1310 nm | ≤0.4 dB/km | TBC — confirm controlled fiber/cable source and test basis |
| Attenuation at 1550 nm | ≤0.3 dB/km | TBC — confirm controlled fiber/cable source and test basis |
| Maximum attenuation difference, 1285–1330 nm | ≤0.03 dB/km | TBC |
| Maximum attenuation difference, 1525–1575 nm | ≤0.02 dB/km | TBC |
| Zero-dispersion wavelength | 1312 ± 10 nm | TBC |
| Zero-dispersion slope | ≤0.090 ps/(nm²·km) | TBC |
| Cable cut-off wavelength | ≤1260 nm | TBC; source symbol also requires correction |
| Mode-field diameter at 1310 nm | 9.2 ± 0.4 μm | TBC |
| Mode-field diameter at 1550 nm | 10.4 ± 0.5 μm | TBC |
| Effective group index at 1310 nm | 1.466 | TBC |
| Effective group index at 1550 nm | 1.467 | TBC |
| Point discontinuity at 1310 nm | ≤0.05 dB | TBC |
| Point discontinuity at 1550 nm | ≤0.05 dB | TBC |
| Cladding diameter | 124.8 ± 0.7 μm | TBC |
| Cladding non-circularity | ≤0.7% | TBC |
| Coating diameter | 254 ± 5 μm | TBC |
| Coating-cladding concentricity error | ≤12.0 μm | TBC |
| Coating non-circularity | ≤6.0% | TBC |
| Core-cladding concentricity error | ≤0.5 μm | TBC |
| Curl radius | ≥4 m | TBC |
The V4 trace also identifies three PMD values with missing units. They are intentionally excluded from the draft. Do not add them until engineering confirms the parameter names, units, statistical conditions, and controlled source.
ITU-T G.652 defines attributes for single-mode optical fiber and cable, including attenuation and PMD-related cable attributes. It does not prove that an individual P014 production lot has been tested or accepted. The values above are not a link-loss budget and do not include splice, connector, passive component, engineering margin, or field-installation loss.
Interfaces and connector options
This is a bulk outdoor cable record. No connector, end-face polish, pre-termination, breakout, gland, pulling eye, messenger, or termination hardware is confirmed in the supplied P014 source.
TBC — source required: available cable-end preparation, pulling accessories, gland compatibility, closure/terminal compatibility, and any factory pre-termination option.
Fiber type and configuration options
Select one P014 fiber count: 16F, 24F, 32F, 48F, 72F, 96F, or 144F. G.652.D is listed in the working record but must be confirmed against the controlled document and purchase-order specification.
Do not substitute G.657.A1, a different GYTS count page, or another armored cable family without checking the complete construction, dimensions, mechanical limits, route qualification, and approved documentation.
Application and compatibility boundary
The current record says the cable is offered for outdoor access and distribution, but it does not provide an approved installation-method statement. The page must not claim duct, lashing, self-supporting aerial, direct burial, anti-rodent, UV, flame, chemical, water-penetration, or electrical-environment suitability until the exact P014 construction and test basis are confirmed.
Before selection, state:
- route type and support method;
- duct size/fill or aerial support arrangement;
- pulling distance, bends, and hardware;
- burial method and soil/rock exposure, if applicable;
- ambient and installation temperatures;
- water, UV, chemical, fire, and rodent requirements;
- required standards, certifications, and acceptance tests.
How to select the correct model or configuration
- Confirm that P014 is the approved product owner rather than a duplicate of another GYTS family page.
- Choose one fiber-count row and keep its tube plan, dimensions, weight, and mechanical limits together.
- Confirm G.652.D and the controlled cable construction.
- State the route and support method instead of relying on the word
armored. - Obtain the approved datasheet/drawing revision and applicable test-document schedule.
- Confirm drum length, total length, marking, packaging, destination, and commercial terms in the quotation.
Differences from related products
| Related record | Known differentiator | Buyer action |
|---|---|---|
| P015 GYTS 72F / 96F | Working record identifies G.657.A1 | Do not substitute for P014 G.652.D without an approved design decision |
| P016 GYTS 8F / 12F / 24F | Working record identifies an 8.6 mm configuration | Use only if its exact diameter/construction fits the project |
| P178 GYTS 24F duct cable | Exact 24F record with a separate source trace | Product owner must decide whether it is a distinct SKU or a P014 variant |
| P089 GYTS 48F G.652.D duct cable | Exact 48F record with a separate source trace | Product owner must decide whether it is a distinct SKU or a P014 variant |
| P090 GYTS 12F–144F family | Overlapping counts and a different source/configuration record | Compare the controlled drawings; merge if commercial role and construction are the same |
| GYTA / GYTA53 / GYXTW / ADSS families | Different family names imply different constructions or deployment roles | Use the exact approved specification; do not infer interchangeability from fiber count |
This table is a page-governance aid, not a performance comparison.
For route-first product browsing, use the BWNFiber fiber optic cable selection page. Compare the 2–24F central loose-tube outdoor armored cable only as a different documented construction. If the route is a subscriber drop rather than a distribution cable, use the FTTH drop cable range. For background on burial-route requirements, see the direct-burial fiber optic cable guide, then confirm the exact model rather than transferring category-level claims to P014.
Use cases
TBC — source required. Release use-case copy only after engineering confirms the exact P014 route and environmental qualifications. Until then, describe buyer requirements rather than asserting suitability.
Testing and quality-control process
No P014-specific test workflow or result is confirmed in the supplied source. Ask BWNFiber to state which documents can be provided for the quoted configuration, such as an approved datasheet/drawing, material or fiber certificate, dimensional inspection, optical test record, mechanical/environmental test reference, and drum/marking inspection.
Do not state 100% tested, name test equipment, cite a standard, or promise a test report unless the QA owner confirms the actual process and document supplied with this product/order.
Packaging and procurement information
The V4 record asks buyers to provide total cable length, length per drum or roll, quantity, cable marking, and delivery destination. Packaging material, standard drum length, MOQ, price, stock, lead time, warranty, export marking, and documentation pack are not confirmed.
TBC — source required: drum type, standard/maximum drum length by count, packaging dimensions/weight, MOQ, lead time, commercial warranty, labeling format, and shipping-document set.
Required information for an RFQ
Send the following as one controlled requirement set:
- product reference: P014 / GYTS 16–144F G.652.D working family;
- selected fiber count;
- required fiber grade and any customer specification;
- route type, support method, and environmental conditions;
- total length and length per drum;
- quantity;
- cable marking and labeling requirements;
- destination and requested Incoterm, if applicable;
- required datasheet, drawing, certificates, and test documents;
- required standards/certifications, subject to BWNFiber confirmation;
- requested sample or pre-production approval, if needed;
- target schedule, subject to quotation.
Datasheet / drawing / test-report download area
| Document | Status |
|---|---|
| Controlled P014 datasheet | TBC — source required |
| Count-specific construction drawing | TBC — source required |
| Approved optical/mechanical specification | TBC — source required |
| Test-document schedule | TBC — QA owner confirmation required |
| Certification/standards declaration | TBC — do not infer |
Do not show a download button until the exact approved file, revision, ownership, and public-release permission are confirmed.
Request a configuration review
Request the controlled P014 datasheet and a configuration-checked quotation. Send the selected fiber count, route/support method, total and drum lengths, quantity, marking, destination, and required documents. BWNFiber should confirm the controlling revision and the complete quoted configuration before order approval.
Frequently asked questions
Which fiber counts does this P014 page cover?
The working record lists 16F, 24F, 32F, 48F, 72F, 96F, and 144F. Each count requires its own approved configuration row. Do not combine dimensions or mechanical values from different counts.
Is the fiber type G.652.D?
G.652.D is listed in the working record. Confirm it in the controlled datasheet and purchase-order specification before release.
Does steel-tape armor mean the cable is approved for direct burial?
No. Armor construction alone does not establish a route approval. Direct-burial suitability depends on the complete cable design, mechanical/environmental qualification, installation method, and project requirements.
Can this cable be installed aerially?
The supplied P014 folder does not confirm an aerial support method or self-supporting design. State the support arrangement and route loads, then obtain engineering confirmation. Do not treat GYTS as ADSS.
What bend radius should be used?
The V4 record contains conflicting or incomplete bend-radius labels. Use the approved P014 datasheet value for the selected count and distinguish the installation/under-tension limit from the installed/static limit.
What attenuation values apply?
The working record lists ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm, pending source confirmation. These values are not a complete link-loss budget.
Can a 24F or 48F page be used instead of P014?
Only after the product owner confirms that the controlled construction and commercial SKU are the same. Similar model names and fiber counts do not prove interchangeability.
Which documents should a buyer request?
Request the controlled datasheet and drawing revision, selected configuration, applicable test-document list, marking/drum plan, and quotation. Ask for standards or certification evidence only when the project requires it.
Are price, MOQ, stock, and lead time available on this page?
No approved values were supplied for this review. They must be confirmed in the quotation.
What information should be included in the RFQ?
Include the selected count, fiber grade, route/support method, environment, total and drum lengths, quantity, marking, destination, required documents, and requested schedule.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.