Outdoor Fiber Cable

GYTC8A 2-60F Figure-8 Self-Supporting Fiber Optic Cable

GYTC8A 2-60F Figure-8 Self-Supporting Fiber Optic Cable for outdoor plant use at 2-60F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Figure-8 Self-Supporting Fiber Optic Cable

GYTC8A

Product Summary

GYTC8A is a metallic, Figure-8 self-supporting outdoor fiber cable family with a stranded loose-tube core, steel central strength member, aluminum-polyethylene laminate (APL), and an integrated stranded-steel messenger inside a PE sheath. The supplied BWNFiber record lists 2-60 fibers, but the first fiber-count row must be corrected before publication.

For buyers: use this page to prepare a model-level request, not to release a route design. Select the fiber grade and count, then provide span and support conditions, messenger requirements, clamp and pole hardware, wind and ice assumptions, installation temperature, drum length, marking, quantity, and required approval documents. BWNFiber should return an approved datasheet or drawing with the exact cable dimensions, messenger diameter, tensile limits, and configuration-specific test requirements before order approval.

Primary action: Request the approved GYTC8A datasheet and a configuration review.
Secondary action: Send a route profile and RFQ schedule.

What This GYTC8A Configuration Is

The supplied product record describes GYTC8A as a stranded loose-tube cable core built around a steel central member. An APL layer surrounds the core, while a stranded-steel messenger is integrated with the cable body in a Figure-8 PE sheath. This construction is intended for a self-supporting aerial route, subject to the approved messenger, tensile, span, sag, wind, ice, clamp, clearance, and installation data for the ordered configuration.

This is not an all-dielectric cable. If the route restricts metallic elements or runs near electrical infrastructure, the project engineer should evaluate an approved ADSS configuration instead.

Key Configuration Points

  • Model family: GYTC8A.
  • Declared family range: 2-60 fibers; the first count-group row is unresolved and must not be released as final.
  • Fiber options in the supplied record: G.652, G.655, 50/125 µm, and 62.5/125 µm.
  • Cable core: stranded loose tubes around a steel central strength member.
  • Barrier: aluminum-polyethylene laminate (APL), as stated in the supplied record.
  • Support element: stranded-steel messenger integrated into the Figure-8 PE sheath.
  • Jacket: PE, with the exact compound and any UV or other project rating TBC — source required.
  • Cable dimensions and messenger diameter: TBC — source required.
  • Tensile limits and engineered span: TBC — source required; they cannot be inferred from the family name.

Provisional Technical Specifications

The values below reproduce the supplied V4/F0071 record for engineering review. They are not publication-ready specifications until BWNFiber approves the source table, units, test conditions, and model mapping.

ParameterProvisional value from supplied recordRelease status
Fiber-count family2-60FHold: first row conflict must be resolved
Fiber optionsG.652 / G.655 / 50/125 µm / 62.5/125 µmHold: confirm exact sub-grades and allowed model combinations
ConstructionStranded loose-tube core; steel central strength member; APL; integrated stranded-steel messenger; Figure-8 PE sheathHold: approve drawing and terminology
JacketPEHold: compound/rating evidence required
Crush resistance300 / 1000 N per 100 mmHold: confirm long-term/short-term order and test method
Bend radius10D / 20DHold: confirm static/dynamic order and whether D is overall cable diameter
Storage / operating temperature-40°C to +70°CHold: source combines conditions; confirm installation range separately
Tensile performance“According to messenger steel-wire diameter”Not a specification; exact values required per messenger option
Overall dimensionsNot supplied in V4TBC — source required
Messenger diameter / constructionNot supplied in V4TBC — source required
Declared cable standardNot supplied in V4TBC — source required

Count-Group Matrix

Catalog modelFiber-count cellLoose tubesFillersReference weight (kg/km)TensileRelease status
GYTC8A-2~6XnTBC — source record prints 2-12 while the model prints 2-614158TBC by messenger diameterBlocked
GYTC8A-8~12Xn8-1223158TBC by messenger diameterEngineering review
GYTC8A-14~18Xn14-1832158TBC by messenger diameterEngineering review
GYTC8A-20~24Xn20-2441158TBC by messenger diameterEngineering review
GYTC8A-26~30Xn26-3050158TBC by messenger diameterEngineering review
GYTC8A-32~36Xn32-3660167TBC by messenger diameterEngineering review
GYTC8A-38~48Xn38-4841172TBC by messenger diameterEngineering review
GYTC8A-50~60Xn50-6050172TBC by messenger diameterEngineering review

Xn is described in the supplied record as a fiber-type suffix. BWNFiber must confirm the exact ordering code and permitted fiber grades before this notation is shown to buyers.

Provisional Optical Characteristics

These values are copied from the supplied record, not from competitor pages. BWNFiber must confirm the exact fiber sub-grade, test reference, and acceptance limits for each order.

Fiber option1310 nm attenuation1550 nm attenuation850 nm attenuation1300 nm attenuation850 nm bandwidth1300 nm bandwidthCable cutoffNumerical aperture
G.652≤0.36 dB/km≤0.22 dB/km————≤1260 nm—
G.655≤0.40 dB/km≤0.23 dB/km————≤1450 nm—
50/125 µm——≤3.3 dB/km≤1.2 dB/km≥500 MHz·km≥500 MHz·km—0.200 ± 0.015
62.5/125 µm——≤3.5 dB/km≤1.2 dB/km≥200 MHz·km≥500 MHz·km—0.275 ± 0.015

Do not combine values from different fiber rows into one configuration. Replace the generic names with the approved fiber designations in the final datasheet.

How to Select the Correct GYTC8A Configuration

  1. Confirm the route role. State whether the cable is for access, distribution, or another outdoor aerial segment.
  2. Provide the span schedule. Include maximum and ruling spans, pole spacing, attachment heights, clearances, and route changes.
  3. Define environmental loads. Provide wind, ice, temperature, coastal or industrial exposure, and any local clearance or grounding constraints.
  4. Set the fiber plan. Specify the approved fiber grade, working fibers, reserve fibers, and count for every segment.
  5. Approve the metallic construction. Confirm that a steel central member, APL, and steel messenger are permitted on the route.
  6. Specify the support system. State messenger construction or required tensile class, sag criteria, clamps, suspension/dead-end hardware, and pole interfaces.
  7. Close dimensional constraints. Confirm cable body and messenger dimensions against clamps, entries, seals, ducts, and handling equipment.
  8. Agree mechanical and test limits. Put tensile, crush, bend, temperature, optical, and acceptance criteria in the purchase specification.
  9. Define delivery details. State total quantity, length per drum, marking, drum requirements, destination, and document language.
  10. Approve controlled documents. Do not release production until the part number, datasheet, drawing, deviation list, and test plan agree.

How GYTC8A Differs From Related Aerial Cable Pages

Cable/page roleConstruction focusUse this page whenDo not assume
GYTC8A (this page)Stranded loose-tube core, APL, steel central member, integrated steel messenger, 2-60F familyThe buyer needs an exact GYTC8A metallic Figure-8 configurationThat family-level data proves a span, tensile class, UV rating, or standard compliance
BWNFiber Aerial Figure-8 Unitube Armored CablePublished 2-12F unitube product with steel armor and PE jacketThe requested construction is the published unitube/steel-armored modelThat its dimensions or loads apply to GYTC8A
BWNFiber ADSS cable categoryAll-dielectric self-supporting aerial families selected by span, MAT, RTS, route, and hardwareMetallic elements are restricted or an engineered ADSS route is requiredThat “self-supporting” makes ADSS and metallic Figure-8 cable interchangeable
FTTH drop-cable categorySubscriber-drop constructions and short last-mile routesThe job is the distribution-point-to-premises dropThat a drop-cable family covers a distribution or backbone GYTC8A requirement

Conditional Applications

GYTC8A may be considered for outdoor aerial access or distribution routes that permit metallic strength and support elements. Final suitability depends on a configuration-specific route review. Do not describe the cable as suitable for long span, direct burial, duct, indoor, power-line, coastal, high-wind, high-ice, flame-rated, rodent-resistant, or other special conditions unless the approved model documentation explicitly covers that condition.

Technical Approval and Acceptance Plan

BWNFiber should confirm which of the following can be supplied for the selected part number. Availability is TBC — source required and must not be implied by this draft.

Approval itemWhat the buyer should verifyCurrent evidence status
Controlled datasheetPart number, fiber grade/count, dimensions, weight, messenger, tensile, crush, bend, temperatureMissing approved copy
Cross-section drawingCable body, APL, loose tubes, central member, messenger, sheath dimensionsReference image exists; drawing approval missing
Route/load calculationSpan, sag, wind, ice, safety factor, clamp loads and clearancesNot supplied
Fiber evidenceExact ITU-T/IEC fiber designation and configuration-specific attenuation limitsGeneric entries only
Cable standard / test methodApplicable cable standard and method for mechanical/environmental testsNot supplied
Factory test reportLot identity, optical results, method, limits, date and dispositionNot supplied
Drum and marking planLength tolerance, drum size, protection, marking text and shipping marksNot supplied
Deviation listEvery difference between inquiry, quotation, drawing, sample and productionNot supplied

Suggested Incoming Inspection Sequence

  1. Match model, drum number, fiber count, length, and marking to the purchase order.
  2. Check drum, end seals, sheath, and messenger for visible shipping damage.
  3. Verify cable and messenger dimensions against the approved drawing.
  4. Review the supplier’s configuration-specific optical and mechanical records.
  5. Perform the project’s agreed optical baseline tests before installation.
  6. Record any deviation before the cable is pulled, tensioned, cut, or accepted.

This sequence is a buyer checklist, not a claim about tests already performed by BWNFiber.

RFQ Checklist

Send the following information for a comparable quotation:

  • Model family: GYTC8A.
  • Network role and route drawing.
  • Maximum and ruling spans; pole and attachment details.
  • Wind, ice, temperature, clearance, grounding, and site conditions.
  • Approved fiber designation and fiber count.
  • Required messenger construction, tensile class, sag, and hardware.
  • Cable dimensions or entry/clamp limits.
  • PE sheath and any project-specific jacket requirements.
  • Optical, tensile, crush, bend, temperature, and test requirements.
  • Total cable length, length per drum, quantity, and destination.
  • Cable and drum marking.
  • Required datasheet, drawing, sample, test report, certificate, or inspection documents.
  • Required delivery date and approval milestones.

Copy into an inquiry:

text
Model: GYTC8A
Route / network role: ___
Maximum span / ruling span: ___ / ___ m
Wind / ice / temperature / clearance conditions: ___
Fiber designation and count: ___ / ___F
Messenger / tensile / sag / hardware requirement: ___
Cable and messenger dimension limits: ___
Jacket and project rating: ___
Mechanical and optical acceptance limits: ___
Total length / length per drum / quantity: ___
Marking / packing / destination: ___
Required documents and test reports: ___
Required delivery date: ___

Datasheet, Drawing, and Test-Report Area

  • Approved GYTC8A datasheet: TBC — source required.
  • Configuration drawing: TBC — source required.
  • Route/load review: TBC — project inputs required.
  • Configuration-specific test report: TBC — source and order required.
  • Cable/drum marking artwork: TBC — buyer approval required.
FAQ

Frequently Asked Questions

What is GYTC8A fiber optic cable?

In the supplied BWNFiber record, GYTC8A is a metallic Figure-8 self-supporting outdoor cable family with a stranded loose-tube core, steel central strength member, APL layer, integrated stranded-steel messenger, and PE sheath. The ordered configuration must be confirmed by an approved datasheet and drawing.

What fiber counts are available?

The supplied record presents a 2-60F family. Its first catalog row is internally inconsistent: the model says 2-6 while the fiber-count cell says 2-12. BWNFiber engineering must correct that row before the count range is published or quoted.

Which fiber types can be ordered?

The provisional record lists G.652, G.655, 50/125 µm, and 62.5/125 µm. The approved sub-grade and permitted combination must be stated on the final part number, datasheet, and purchase specification; the listed alternatives do not all apply to one cable.

Is GYTC8A the same as ADSS cable?

No. This GYTC8A record includes metallic elements: a steel central member, APL, and steel messenger. ADSS is all-dielectric. Route constraints, electrical environment, span design, hardware, and approved load data determine which family can be considered.

Does “self-supporting” define the allowable span?

No. The term describes the support concept, not an approved span. Maximum and ruling spans require configuration-specific messenger, tensile, sag, wind, ice, temperature, clamp, clearance, and safety data.

Can the listed 10D/20D bend-radius values be used for installation?

Not yet. The supplied record lists 10D/20D but does not identify the static/dynamic order or fully define D. The approved datasheet must state both conditions and the applicable overall cable dimension.

What do the 300/1000 N per 100 mm crush values mean?

The supplied record lists these two values without clearly mapping them to long-term and short-term conditions or naming the test method. Treat them as provisional until the approved specification states the order, method, and acceptance criteria.

Is the PE sheath automatically UV-resistant or flame-retardant?

No. “PE” alone does not prove a UV rating, flame behavior, regional approval, or suitability for every outdoor condition. Request the exact compound and project-specific evidence needed for the route.

What must be confirmed before an RFQ can be compared?

Use the same route, span, fiber, messenger, dimensions, mechanical limits, optical limits, drum lengths, documents, delivery basis, and acceptance criteria for every supplier. Otherwise, lower pricing may represent a different cable rather than a comparable offer.

What should be approved before production release?

Approve the exact part number, datasheet, cross-section drawing, route/load assumptions, deviation list, test plan, marking, drum schedule, quantity, and delivery requirements. Any contradiction should remain open until the responsible engineer resolves it.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.