GYTA53
GYTA53 2-216F Stranded Loose Tube Armored Fiber Optic Cable
GYTA53 2-216F Stranded Loose Tube Armored Fiber Optic Cable with documented armored construction at 2-216F. Match armor and jacket to the route before quoting.

Product value summary
The BWNFiber GYTA53 cable family covers 2–216 fibers in a stranded loose-tube construction with a steel central member, APL, PE inner sheath, water-blocking elements, PSP steel tape and PE outer sheath as recorded in the supplied product data. Use the tables to shortlist a fiber count and fiber grade; then confirm the exact jacket, installation route, test method and delivery configuration before order release.
Short answer for buyers
This page is for a GYTA53 2–216F model family, not one universal cable build. Select one fiber count group and one optical option. Do not combine G.652, G.655, 50/125 μm and 62.5/125 μm values in one RFQ. The current record lists PE jacket and -40°C to +70°C storage/operating temperature; UV, installation-temperature and route suitability remain TBC — source required.
Key features
- Fiber-count groups from 2F through 216F.
- Stranded loose tubes with a steel central member, as recorded in the current product record.
- APL, PE inner sheath, water blocking, PSP steel tape and PE outer sheath in the recorded construction sequence.
- G.652, G.655, 50/125 μm and 62.5/125 μm options listed as alternatives.
- PE jacket listed in the current order guide.
- Mechanical and optical values shown for technical shortlisting; final values require the released order datasheet.
Cable construction
| Component / parameter | Recorded specification |
|---|---|
| Fiber count | 2–216F |
| Fiber option | G.652 / G.655 / 50/125 μm / 62.5/125 μm — select one |
| Central member | Steel |
| Core construction | Gel-filled stranded loose tubes + fillers where shown in the catalog row |
| Moisture/metal layers | APL; water blocking; PSP steel tape |
| Sheaths | PE inner sheath and PE outer sheath |
| Jacket | PE in the current order record; material/rating documents TBC |
Configuration and mechanical table
| Catalog model | Fiber count | Loose tubes | Fillers | Ref. weight (kg/km) | Tensile long/short (N) | Crush long/short (N/100 mm) | Bend radius |
|---|---|---|---|---|---|---|---|
| GYTA53-2~6Xn | 2–6 | 1 | 5 | 177 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-8~12Xn | 8–12 | 2 | 4 | 177 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-14~18Xn | 14–18 | 3 | 3 | 177 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-20~24Xn | 20–24 | 4 | 2 | 177 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-26~30Xn | 26–30 | 5 | 1 | 177 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-32~36Xn | 32–36 | 6 | 0 | 177 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-38~48Xn | 38–48 | 4 | 1 | 194 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-50~60Xn | 50–60 | 5 | 0 | 194 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-62~72Xn | 62–72 | 6 | 0 | 204 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-74~84Xn | 74–84 | 7 | 1 | 239 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-86~96Xn | 86–96 | 8 | 0 | 239 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-98~108Xn | 98–108 | 9 | 1 | 275 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-110~120Xn | 110–120 | 10 | 0 | 275 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-122~132Xn | 122–132 | 11 | 1 | 312 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-134~144Xn | 134–144 | 12 | 0 | 312 | 1000/3000 | 1000/3000 | 12.5D/25D |
| GYTA53-146~216Xn | 146–216 | 13–18 | 5–0 | 312 | 1000/3000 | 1000/3000 | 12.5D/25D |
Xn is retained exactly as supplied. Its fiber-type suffix mapping is TBC — source required. Confirm cable diameter, installation bend condition, test method and whether each matrix value applies to every fiber option before approval.
Optical options
| Fiber option | Atten. @1310 | Atten. @1550 | Atten. @850 | Atten. @1300 | BW @850 (MHz·km) | BW @1300 (MHz·km) | Cutoff λcc | NA |
|---|---|---|---|---|---|---|---|---|
| G.652 | ≤0.36 dB/km | ≤0.22 dB/km | — | — | — | — | ≤1260 nm | — |
| G.655 | ≤0.40 dB/km | ≤0.23 dB/km | — | — | — | — | ≤1450 nm | — |
| 50/125 μm | — | — | ≤3.3 dB/km | ≤1.2 dB/km | ≥500 | ≥500 | — | 0.200±0.015 |
| 62.5/125 μm | — | — | ≤3.5 dB/km | ≤1.2 dB/km | ≥200 | ≥500 | — | 0.275±0.015 |
These rows are alternatives. Request the selected fiber grade, test wavelength, test condition and acceptance document in the quotation. Do not use the table as a combined performance claim for one cable.
Environment and application boundary
The supplied record shows storage/operating temperature: -40°C to +70°C. It does not, by itself, establish an installation range, UV rating, flame rating, water-ingress classification, direct-burial approval or certification. Confirm those fields against the order datasheet before specifying an exposed, duct or buried route.
For route selection, compare the exact GYTA53 configuration with the relevant BWNFiber fiber-optic cable selection guide and armored cable mechanical test evidence. If the project requires an all-dielectric path, review the GYFTA53 family instead; do not treat the steel central member as interchangeable with an FRP construction.
How to select the correct configuration
- Select fiber count: choose the catalog group that covers the required active fibers plus project reserve.
- Select one fiber option: specify G.652, G.655, 50/125 μm or 62.5/125 μm; do not mix rows.
- Validate route and evidence: confirm cable diameter, bend condition, jacket/UV/fire requirements, mechanical test method, water management, drum length and destination before order release.
Interfaces and compatibility
No connector, termination, polarity, gender or equipment-compatibility field is supplied for this bulk cable record. Treat it as a cable construction requiring project-specific splicing/termination design unless BWNFiber confirms an assembly option. Connector, transceiver, brand and interoperability claims are TBC — source required.
Testing and quality-control request
The supplied page does not include a test report, test method, sample count, acceptance limit or per-drum trace. Ask BWNFiber to attach the applicable optical and mechanical test evidence to the released order datasheet. Do not claim IEC, ITU-T, ISO, CE, RoHS, UL or other compliance without a matching document for this configuration.
Packaging and procurement information
Packaging, standard drum length, marking, MOQ, price, stock, lead time and warranty are not supplied. Request them rather than inferring them from the fiber count or weight table.
RFQ checklist
Include: (1) GYTA53 2-216F Stranded Loose Tube Armored Fiber Optic Cable; (2) selected catalog model/fiber count; (3) one fiber grade; (4) total length; (5) length per drum or roll; (6) quantity; (7) marking text and packaging requirement; (8) installation route, destination and required documents. Ask BWNFiber to confirm jacket/UV/fire details, diameter, test method, optical acceptance values and delivery terms.
FAQ
Which fiber counts does this GYTA53 page cover?
The supplied record covers 2–216F in count groups from GYTA53-2~6Xn through GYTA53-146~216Xn. Select the exact group before requesting dimensions or a quotation.
Are G.652, G.655, 50/125 μm and 62.5/125 μm combined in one cable?
No. They are alternative fiber options shown in the current record. State one selected grade in the RFQ; the order datasheet governs.
What is the recorded construction?
Gel-filled stranded loose tubes around a steel central member, followed by APL, PE inner sheath, water blocking, PSP steel tape and PE outer sheath as recorded. Confirm the released drawing before production.
Can I specify this cable for direct burial or exposed outdoor use?
Not from the current record alone. PE is listed, but UV, installation range, water-ingress classification, flame rating and route approval are not supplied. Obtain those documents first.
What does Xn mean?
The suffix is retained from the supplied catalog model. Its fiber-type mapping is TBC and must be confirmed by BWNFiber.
What should I send for an accurate quotation?
Send the exact count group, one fiber grade, total and per-drum lengths, quantity, marking, packaging, route, destination and required test/quality documents.
Related Products