GYTA
GYTA 2–216F Loose Tube APL Outdoor Fiber Optic Cable
GYTA 2–216F Loose Tube APL Outdoor Fiber Optic Cable for outdoor plant use at 2-30F / 32-60F / 62-72F / 73-96F / 98-144F / 146-216F. Confirm model, fiber count and installation method against the source drawing.

Product Summary
GYTA is a stranded loose tube outdoor cable family built around a metallic central strength member, loose tubes, an aluminum-polyethylene laminate (APL) moisture barrier and a PE outer sheath. This BWNFiber draft covers provisional fiber-count groups from 2 to 216 fibers. Before quotation or production, confirm the exact fiber grade, count, construction drawing, cable diameter, mechanical limits, temperature range, installation method and required acceptance documents.
Short answer for buyers: use this page when the required cable is specifically a GYTA construction with an APL moisture barrier. Do not substitute a GYTS steel-tape cable, an all-dielectric GYFTY cable or a double-sheath GYTA53 cable on the basis of fiber count alone.
Primary action: Send the route, fiber count, fiber grade, required drum length, quantity and approval-document requirements for a configuration review.
What Is a GYTA Fiber Optic Cable?
A GYTA cable uses fibers in filled loose tubes stranded around a central strength member. An APL layer is applied around the cable core before the PE sheath. In this product family, APL is the radial moisture-barrier layer; it must not be relabeled as corrugated steel tape. The exact construction and materials for the order must match the approved BWNFiber drawing.
Construction identity that must be confirmed
| Construction element | Current evidence | Release status |
|---|---|---|
| Stranded loose tubes | Supplied V4 and supplied product image | Provisional internal fact |
| Metallic central strength member | Supplied image labels a steel-wire strength member; V4 also lists FRP alternatives | TBC — resolve the conflict for GYTA |
| APL moisture barrier | Product name, supplied image and current industry descriptions of GYTA | Supported family identity; exact material record still required |
| PE / HDPE outer sheath | Supplied V4 | TBC — choose the orderable material rather than displaying both as interchangeable |
| Corrugated steel tape | Listed in the supplied V4 table, but conflicts with the GYTA/APL identity | Remove from the GYTA offer unless the approved drawing proves a hybrid construction |
| Water-blocking system | Supplied V4 | TBC — source and method required |
Provisional Configuration Range
The table below preserves the count groups and values in the supplied V4. It is a controlled-review table, not a released datasheet. BWNFiber engineering must verify every row against the approved source before publication or quotation.
| Fiber-count group | Nominal diameter (mm) | Nominal weight (kg/km) | Max. fibers per tube | Tubes + fillers | Tensile load, short / long term (N) | Crush resistance, short / long term (N/100 mm) | Status |
|---|---|---|---|---|---|---|---|
| 2–30 | 8.60 ± 0.5 | 90 ± 5* | 6 | 6 | 1500 / 600 | 1000 / 300 | TBC |
| 32–60 | 9.60 ± 0.5 | 95 ± 5* | 12 | 6 | 1500 / 600 | 1000 / 300 | TBC |
| 62–72 | 10.5 ± 0.5 | 135 ± 5* | 12 | 8 | 1500 / 600 | 1000 / 300 | TBC |
| 73–96 | 12.2 ± 0.5 | 145 ± 5* | 12 | 10 | 1500 / 600 | 1000 / 300 | TBC; verify whether the range starts at 73 or 74 |
| 98–144 | 14.2 ± 0.5 | 204 ± 5* | 12 | 12 | 1800 / 600 | 1000 / 300 | TBC |
| 146–216 | 16.0 ± 0.5 | 205 ± 5* | 12 | 18, two layers | 1800 / 600 | 1000 / 300 | TBC; verify two-layer drawing |
* The V4 source text displays ±05; this draft normalizes the typography to ±5 for review only. Engineering must confirm that interpretation.
Other provisional construction values
| Parameter | Supplied V4 value | Required action |
|---|---|---|
| Loose tube material | PBT | Verify against controlled BOM |
| Loose tube diameter | Ф2.2 (outer/inner) | Invalid/ambiguous as written; supply outside diameter and wall/inside diameter separately |
| Central strength member | Steel wire / FRP / FRP with PE cover | Choose the valid GYTA option by count/configuration |
| Central strength member size | 1.4 mm | Verify whether universal or count-specific |
| Outer sheath | PE / HDPE | Confirm orderable option and naming |
| Outer sheath value | 1.70 ± 0.2 mm, labeled “diameter” in V4 | Verify whether this is sheath thickness; do not use for order release as diameter |
| Standard drum length | 2 km | Confirm standard versus project-specific drum length |
Fiber Grade and Optical Data
The supplied V4 mixes ISO cabling labels (OS1, OS2, OM1–OM4) with three generic fiber rows (SM G652D, MM 50/125, MM 62.5/125). Those labels are not a complete one-to-one order matrix. The final page should name the actual fiber standard and grade offered for each configuration.
| Fiber option in supplied V4 | Wavelength (nm) | Provisional attenuation (dB/km) | Release status |
|---|---|---|---|
| SM G.652.D | 1310 / 1550 | ≤0.36 / 0.23 | TBC — confirm test condition and cabled-fiber limit |
| MM 50/125 | 850 / 1300 | ≤3.0 / 1.0 | TBC — identify OM grade and test condition |
| MM 62.5/125 | 850 / 1300 | ≤3.0 / 1.0 | TBC — identify OM grade and test condition |
Selection rule: specify the exact fiber standard or grade in the RFQ. Do not combine OS1, OS2, OM1, OM2, OM3 and OM4 as if all optical values apply to one cable.
Mechanical and Environmental Limits
| Condition | Supplied V4 value | Release status |
|---|---|---|
| Installation temperature | −15 to +60 °C | TBC — verify source and test/application condition |
| Operation and transport temperature | −40 to +70 °C | TBC — separate operating, storage and transport limits if they differ |
| Minimum bend radius, long term | 10 × cable diameter | TBC for this model |
| Minimum bend radius, short term | 20 × cable diameter | TBC for this model |
The bend values must be interpreted as radius, not pulley diameter. During route approval, use the exact selected cable diameter and do not exceed the approved pulling tension, crush limit or bend radius.
Application and Compatibility Boundaries
This page is intended for an outdoor GYTA cable used in access, distribution or backbone routes where an APL moisture barrier is part of the approved design. The installation method is not proven by the family name alone.
Start with the fiber optic cable selection guide when the route has not yet been assigned to a cable family. Review the fiber cable jacket guide when the project needs a material-versus-rating decision, and use the indoor fiber cable category for building-only pathways.
- Duct or conduit: candidate use; confirm pulling tension, bend path, duct occupancy, water management and the selected cable’s approved installation method.
- Aerial: do not describe this cable as self-supporting. If lash-to-messenger use is proposed, require an approved drawing and route/load review.
- Direct burial: not approved by this draft. Confirm whether the exact construction has the mechanical protection and declared use required by the project.
- Building entry: PE or HDPE material does not by itself prove an indoor fire rating. Define the transition point and local code requirements.
- Connector compatibility: not applicable to the bulk cable until the termination, splice plan and hardware are defined.
GYTA vs. Related Outdoor Cable Families
| Family | Page role / distinguishing question | Do not infer |
|---|---|---|
| GYTA | Does the project require a stranded loose tube cable with an APL moisture barrier and metallic strength member? | Do not call APL corrugated steel tape |
| GYTS | Does the project require a steel-tape armored construction? | Do not merge with GYTA because both are outdoor loose tube cables |
| GYTA53 | Does the route require the approved double-sheath aluminum/steel construction? | Do not reduce it to “higher-count GYTA” |
| GYFTY | Does the route require an all-dielectric FRP loose tube construction? | Do not treat it as interchangeable with metallic GYTA |
| ADSS | Does the route require a self-supporting all-dielectric aerial design with span/load engineering? | Do not use GYTA aerial language to target ADSS intent |
For a self-supporting aerial route, move to the ADSS cable selection page rather than treating GYTA as an equivalent design.
How to Select the Correct GYTA Configuration
- Define the route. State duct, conduit, lashed aerial, entry segment or another approved method; include route length, bends, handholes and environmental exposure.
- Choose the fiber requirement. State the exact fiber standard/grade, working count, spare count and any color-code requirement.
- Select one count row. Keep diameter, weight, tube layout and mechanical limits from the same approved configuration.
- Confirm the construction. Approve the central strength member, loose-tube layout, water-blocking method, APL layer and sheath material from the drawing.
- Check installation limits. Validate pulling tension, crush, bend radius, temperature and hardware against the route.
- Define acceptance evidence. List the datasheet, drawing, optical test data, mechanical/environmental evidence, marking sample and packing record required before shipment.
Procurement and RFQ Checklist
Send the following information for a configuration review:
- Project country and delivery destination
- Network role and installation route
- Exact fiber standard or grade
- Fiber count and spare-fiber policy
- Required cable construction and sheath material
- Route length and required length per drum
- Quantity and drum count
- Pulling, crush, bend and temperature requirements
- Cable marking text and unit convention
- Required drawing, datasheet, test report or certificate
- Packaging and shipping requirements
- Required delivery date; lead time and MOQ remain quotation-specific
Testing and Quality-Control Evidence to Request
The current file does not include an approved BWNFiber test plan or report. Before release, define which checks apply to the exact configuration and what document will prove them.
| Check | Buyer purpose | Evidence required before the claim is published |
|---|---|---|
| Fiber continuity and attenuation | Confirm optical path and cabled-fiber performance | Approved test method, wavelengths, limits and report format |
| Cable dimensions and mass | Verify duct, clamp, reel and handling fit | Approved drawing and dimensional inspection record |
| Tensile and crush performance | Check installation/mechanical limits | Applicable method, sample configuration and acceptance limits |
| Water penetration / moisture protection | Validate the route-specific protection claim | Applicable method and exact construction tested |
| Temperature cycling | Validate environmental range | Test method, range, duration and acceptance criteria |
| Sheath marking and drum packing | Prevent receiving and installation mix-ups | Approved marking proof and packing record |
No claim that every cable is “100% tested,” certified, standards-compliant or suitable for a named installation method should be added without controlled evidence for this model.
Downloads
- Controlled product datasheet: TBC — source required
- Approved construction drawing: TBC — source required
- Configuration-specific test report: Available only if confirmed for the order; TBC
- Packing and drum drawing: TBC — source required
Frequently Asked Questions
What does the GYTA page cover?
This draft is intended to cover an APL stranded loose tube outdoor cable in provisional count groups from 2 to 216 fibers. The released range must match the controlled datasheet; the current V4 also contains a conflicting “2–144 cores” statement.
Is APL the same as corrugated steel tape?
No. APL refers to an aluminum-polyethylene laminate used around the cable core. The supplied V4’s corrugated-steel-tape row conflicts with the GYTA/APL identity and must be resolved before publication.
Is GYTA the same as GYTS?
No. The pages should remain separate because the construction-defining metallic layer differs. GYTA should own APL moisture-barrier intent; GYTS should own steel-tape construction intent.
Can this GYTA cable be installed directly underground?
Not on the family name alone. Direct-burial suitability requires the exact construction, mechanical protection and declared installation use to be confirmed by an approved product document.
Can GYTA be installed aerially?
GYTA is not a self-supporting cable by default. Any lash-to-messenger or other aerial method requires route, support, load and approved-construction confirmation. Use an ADSS page for self-supporting aerial intent.
Which fiber grade should be ordered?
Specify the actual fiber standard or grade required by the network design. The current draft’s OS1/OS2/OM1–OM4 list is broader than its optical table and cannot be released as a complete compatibility matrix.
How should the fiber count be selected?
Calculate working fibers, redundancy, spare capacity and branch requirements, then select one approved count row. Keep that row’s diameter, tube layout and mechanical values together.
What bend radius applies?
The supplied V4 lists 20D short term and 10D long term, where D is cable diameter. Treat these as provisional until the exact configuration’s datasheet is approved; do not confuse bend radius with pulley diameter.
What must be confirmed before a quote?
Provide the route, fiber grade and count, construction, drum lengths, quantity, marking, delivery destination, required test evidence and approval documents. Any unresolved alternative must be selected rather than copied into the order description.
Which documents should a buyer request?
Request the controlled datasheet, approved construction drawing, configuration-specific optical/mechanical evidence, cable-marking proof and packing record. Certification or standards claims should appear only when the exact document and scope are available.