Indoor Fiber Cable

GYFXTY 1-24F Dual-FRP Unitube Fiber Optic Cable

GYFXTY 1-24F Dual-FRP Unitube Fiber Optic Cable for indoor building or equipment-room routes at 1-24F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

GYFXTY

Product summary

The BWNFiber GYFXTY page is intended to identify a dual-FRP unitube fiber optic cable configuration with HDPE outer sheath options and grouped fiber-count rows. The supplied record lists 1–6F, 8–12F and 16–24F groups, with different dimensions, weights and tensile values. Confirm the fiber grade and approved installation environment before specifying this cable.

Do not interpret “1–24F” as proof that every individual count is available. Use only the count or group confirmed in the quotation.

Technical review notice: Values and configuration statements on this offline draft are based on the supplied product record. They remain subject to BWNFiber engineering confirmation and are not a guarantee of finished-cable performance, availability, compatibility or delivery.

Configuration at a glance

AttributeSupplied valuePublication status
Cable familyGYFXTYSupplied product record
StructureUnitube; dual FRP values are listed by groupEngineering review required
Fiber-count groups1–6F; 8–12F; 16–24FPublish only as grouped ranges until exact count list is confirmed
Outer sheathHDPEConfirm material grade and environment
Fiber type/gradeTBC — not stated in the supplied pageSource required
ConnectorsTBC — no connector configuration is statedConfirm cable-only vs factory-terminated
ApplicationTBC — “indoor distribution” and “aerial/indoor” conflictEngineering decision required

Technical specifications by listed group

Keep each row together when transferring this table into the CMS. Do not combine a dimension from one group with a mechanical value from another.

Parameter1–6F8–12F16–24F
Loose-tube size (mm)1.82.02.6
Dual FRP notation in source (mm)2 × 0.82 × 0.82 × 1.0
Outer sheathHDPEHDPEHDPE
Cable diameter (mm)5.25.56.8
Cable weight (kg/km)232538
Crush resistance (N/100 mm)100010001000
Tensile strength (N)100010001200
Minimum bend radius — installation20 × cable diameter20 × cable diameter20 × cable diameter
Minimum bend radius — installed10 × cable diameter10 × cable diameter10 × cable diameter

Source control note: The supplied editorial review flags this multi-column table for engineering alignment review. Values must not be published as final until the source row mapping is signed off.

Fiber characteristics — source scope to confirm

The supplied record lists the following optical values. It does not clearly identify whether each value is a bare-fiber specification, finished-cable acceptance value, or another test scope. Keep the scope label with every value until the source is confirmed.

ParameterSupplied valueStatus
Mode-field diameter at 1310 nm9.2 ± 0.4 μmTBC — fiber grade/source scope
Cladding diameter125 ± 1 μmTBC — fiber grade/source scope
Cut-off wavelength for cable≤1260 nmTBC — test method/source scope
Attenuation at 1310 nm≤0.36 dB/km (max.)TBC — object/test method
Attenuation at 1550 nm≤0.21 dB/km (max.)TBC — object/test method
Chromatic dispersionListed at 1288–1339 nm and 1550 nmTBC — fiber grade/source scope

These figures do not by themselves establish a complete link-loss budget, connector loss, splice loss, transmission reach, standards compliance, or compatibility with a named optical module.

Application and compatibility boundary

Use this page for exact model/configuration validation only. The approved environment is TBC. Before ordering, confirm:

  • indoor, aerial, duct, or indoor-to-outdoor transition use;
  • whether the HDPE sheath has the required UV, flame and environmental properties;
  • whether a support messenger, span limit or external support is required;
  • fiber grade and the optical equipment/link budget;
  • whether the order is cable-only or requires factory termination.

Do not substitute this page for an outdoor cable, armored cable, drop cable, or connectorized assembly without a configuration review.

How to select the correct configuration

  1. Confirm the exact fiber count; do not infer availability for unlisted individual counts.
  2. Confirm fiber type/grade and the required operating link budget.
  3. Confirm the installation environment and sheath requirements.
  4. Select the matching grouped row for diameter, weight, tensile strength and crush resistance.
  5. Confirm bend-radius rules for installation versus installed condition.
  6. Request the approved drawing/datasheet and test documentation before release.

Testing and documentation

The supplied page does not include a test method, test equipment, sampling plan, acceptance report, drawing, or certification record. Add these only when BWNFiber supplies them:

  • TBC — cable construction drawing
  • TBC — fiber/cable test method and report
  • TBC — standards or certification evidence
  • TBC — packaging, drum/roll length and marking specification

RFQ checklist

Send the following with the quotation request:

  • Product: GYFXTY 1–24F Dual-FRP Unitube Fiber Optic Cable
  • Exact fiber count or approved group
  • Fiber type/grade: TBC — buyer to confirm
  • Jacket: HDPE, with required environmental/flame/UV scope
  • Total cable length
  • Length per drum or roll
  • Quantity
  • Cable marking text
  • Delivery destination
  • Installation environment and support/span requirements, if applicable
  • Required drawing, datasheet, test report or sample
  • Cable-only or connectorized requirement

CTA: Request a configuration review and quotation. Include the fields above so BWNFiber can confirm the applicable row before pricing.

FAQ

FAQ

Which fiber-count configurations are listed?

The supplied table lists 1–6F, 8–12F and 16–24F groups. Confirm the exact orderable count with BWNFiber; the range label does not prove that every individual count is available.

Is this cable approved for indoor or aerial installation?

The supplied record uses both “indoor distribution” and “aerial/indoor.” The approved application is TBC. Confirm the environment, sheath requirements and any support/span conditions before ordering.

What are the bend-radius limits?

The supplied record lists 20 × cable diameter during installation and 10 × cable diameter after installation. The source table requires engineering review before these values are released as final product limits.

Are the attenuation figures a complete link budget?

No. The supplied figures are not enough to calculate a complete link budget, and their test object/scope is not yet confirmed. Connector, splice, equipment and design losses must be assessed separately.

Does the page specify connectors or compatibility?

No connector configuration or named equipment compatibility is supplied. Treat the item as cable-only unless BWNFiber confirms a factory-terminated configuration.

What should be included in an RFQ?

Provide the exact count, fiber grade, jacket/environment, length, packaging, marking, destination and documentation requirements. Ask BWNFiber to confirm the matching configuration row before order release.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.