GYFXTS
GYFXTS 1-12F Glass-Yarn Steel-Tape Armored Outdoor Fiber Optic Cable
GYFXTS 1-12F Glass-Yarn Steel-Tape Armored Outdoor Fiber Optic Cable for outdoor plant use at 1-12F. Confirm model, fiber count and installation method against the source drawing.

Short Answer
The source-listed BWNFiber GYFXTS configuration is a compact 1–12-fiber outdoor cable built around a PBT loose tube, E-glass-yarn strength member and steel-tape armor. The source lists a nominal 8.0 mm cable diameter, 83 kg/km cable weight, multiple single-mode and multimode fiber options, and separate installation and service limits. These values remain subject to BWNFiber engineering confirmation because the underlying record contains sparse or merged cells.
Do not approve aerial, duct or direct-burial use from the words outdoor or armored alone. Ask for the current model-specific datasheet, construction drawing, declared installation methods and applicable test evidence before releasing a purchase order.
Primary action: Request the current GYFXTS datasheet and ask BWNFiber to review your route and selected configuration.
Technical Notice
The figures below are source-listed review values, not contractual guarantees. Confirm every value, condition and option against the current approved BWNFiber datasheet and quotation for the exact configuration.
Configuration at a Glance
| Selection field | Source-listed value | Approval status |
|---|---|---|
| Model | GYFXTS | Confirm exact revision |
| Fiber count | 1–12F | Select one count; confirm availability |
| Fiber options | SM G.652 / G.652.D; MM 50/125; MM 62.5/125; MM OM3-300 | Select one grade; confirm nomenclature and supply |
| Loose tube | PBT, 2.8 ± 0.2 mm | Confirm on controlled construction drawing |
| Strength member | E-glass yarn | Confirm material, placement and function |
| Armor | Steel tape | Tape type, coating and coverage: TBC |
| Overall cable diameter | 8.0 mm nominal | Diameter tolerance: TBC |
| Cable weight | 83 kg/km | Confirm nominal value and tolerance |
| Outer sheath | TBC — source required | Do not infer PE, LSZH, UV or flame properties |
| Water-blocking system | TBC — source required | Do not claim water resistance without evidence |
| Declared installation methods | TBC — source required | Aerial, duct and burial approval remain open |
The model name is not a complete purchase specification. The quotation should identify one fiber count, one fiber grade, required length, length per drum or roll, marking, destination and the documents needed for approval.
Source-Listed Technical Specifications
Optical characteristics
| Fiber option | Wavelength | Source-listed attenuation | Status |
|---|---|---|---|
| SM G.652 | 1310 / 1550 nm | ≤0.36 / 0.23 dB/km | Test method and maximum/typical basis: TBC |
| SM G.652.D | 1310 / 1550 nm | ≤0.36 / 0.23 dB/km | Test method and maximum/typical basis: TBC |
| MM 50/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Exact grade and conditions: TBC |
| MM 62.5/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Exact grade and conditions: TBC |
| MM OM3-300 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Product naming and bandwidth evidence: TBC |
ITU-T G.652 defines attributes for single-mode optical fiber and cable, but citing the Recommendation does not prove that a particular manufactured cable complies with it. Confirm the exact fiber designation on the controlled datasheet and purchase specification.
Mechanical and environmental values
| Parameter | Source-listed value | Buyer check |
|---|---|---|
| Minimum bend radius, long term | 10D | Confirm whether the approved term is static; D is finished cable diameter |
| Minimum bend radius, short term | 20D | Confirm whether the approved term is dynamic/installation |
| Tensile load, long term | 900 N | Test method and acceptance criterion: TBC |
| Tensile load, short term | 1000 N | Test method and acceptance criterion: TBC |
| Operating temperature | -40 to +70 °C | Confirm exact model/configuration |
| Installation temperature | -20 to +60 °C | Confirm handling and pulling conditions |
| Storage temperature | -40 to +70 °C | Recovered from sparse source; engineering review required |
| Crush resistance | TBC — source required | Required before route approval |
IEC 60794-1-2 provides general guidance on optical-cable test procedures. It does not establish that this GYFXTS configuration was tested, passed a particular method or meets a project-specific limit. Request model-traceable test evidence when the purchase specification requires it.
What Must Be Confirmed Before Route Approval?
An outdoor cable decision starts with the physical route. Separate every aerial, duct, conduit, exposed, buried and building-entry segment. Then compare the route requirements with one controlled model revision.
Use the fiber optic cable selection guide to define the cable family, and the armored vs direct-burial route approval guide to keep construction features separate from installation declarations.
Hold approval until the following questions are closed:
- What installation methods does the exact model declare? The current source does not prove self-supporting aerial, duct, direct-burial or indoor use.
- What is the complete cross-section? Confirm tube filling, water-blocking layers, steel-tape construction, ripcord and outer sheath.
- Which mechanical limits apply? Confirm tensile, crush, impact and bend limits with long/short-term conditions and the applicable test method.
- How will metallic armor be handled? The project owner must define any grounding, bonding, isolation and termination requirements.
- Does the cable fit every interface? Match the confirmed diameter and tolerance to ducts, glands, closures, seals, clamps and pulling equipment.
- What happens at a building entry? Outdoor suitability does not establish a building fire or smoke rating. Confirm the transition point and local requirements.
- Which documents control the order? Use a revision-controlled datasheet, construction drawing, agreed deviation list and quotation tied to the same configuration.
How to Select the Correct GYFXTS Configuration
Define the route and network role
State whether the cable will be used in an access, distribution, backbone or another link. Mark each installation segment and identify pulling distance, bends, water exposure, mechanical loading, entries and splice locations.
For family-level discovery, compare the published outdoor fiber optic cable range. For execution planning, review the separate fiber optic cable installation guide.
Select one fiber grade and one count
Choose the fiber grade from the active equipment, wavelength, reach, link budget and project requirements. Then select the working-fiber count plus any project-approved reserve. Do not combine every fiber option shown on this page into one order description.
Convert route risks into cable requirements
Record required tensile and crush limits, bend conditions, sheath properties, water-blocking expectations, temperature ranges, armor treatment, dimensions and document requirements. If any requirement is absent from the controlled model evidence, list it as an open deviation.
Match interfaces and logistics
Confirm closure and gland ranges, drum access, pulling direction, planned splice points, reel length, cable marking and destination. A nominal 8.0 mm diameter is not sufficient for interface approval until its tolerance is confirmed.
Approve documents before the purchase order
Ask BWNFiber to return the current datasheet, construction drawing, configuration confirmation and a written response to every required document or test item. Any alternative should be rechecked rather than accepted as an unspecified equivalent.
How This Page Differs From Related BWNFiber Pages
| Page or family | Intended owner | Key distinction | Link role |
|---|---|---|---|
| GYFXTS 1–12F (this page) | Exact GYFXTS configuration and RFQ | Source lists E-glass yarn, steel tape and nominal 8.0 mm diameter | Exact-model validation |
| 2–12F central loose-tube armored page | Published GYXTW 2–12F configuration | Live page identifies two parallel steel wires and different mechanical values | Compare strength-member construction |
| 2–24F central loose-tube armored page | Wider central-loose-tube range | Live page identifies Kevlar, steel tape and different dimensions/values | Compare fiber-count range and controlled model |
| Armored / Direct Burial Cable guide | Broad route selection | Explains why armored and direct-burial are not interchangeable | Route-approval education |
| Outdoor Fiber Optic Cable category | Outdoor family discovery | Broad family and installation-route selection | Parent category |
This table defines page roles; it does not claim that one construction performs better. A controlled datasheet and route requirements are needed for a technical comparison.
Required Information for an RFQ
Send one complete requirement set:
- Product/model: GYFXTS, with the required revision or approved construction
- Installation route: each aerial, duct, conduit, exposed, buried and indoor segment
- Network role and link length
- Fiber grade and exact fiber count
- Required attenuation or link-budget conditions and acceptance wavelengths
- Required tensile, crush, bend, impact and temperature limits
- Outer-sheath, water-blocking and metallic-armor requirements
- Total cable length and length per drum or roll
- Drum access, pulling direction and planned splice locations
- Cable marking, language and packaging requirements
- Required datasheet, drawing, test records, certificates and inspection documents
- Quantity, destination and requested delivery window
Price, MOQ, availability and lead time are TBC — controlled quotation required.
Datasheet, Drawing and Test-Report Area
- Current GYFXTS datasheet: TBC — source required
- Revision-controlled construction drawing: TBC — source required
- Declared installation-method statement: TBC — source required
- Model-specific test report or inspection plan: TBC — source required
- Packing and drum-length specification: TBC — source required
Do not display download buttons until the files exist, match the exact model and have release approval.
Request a GYFXTS Configuration Review
Send BWNFiber your route drawing or route description, selected fiber grade and count, required lengths, mechanical and environmental requirements, document list, quantity and destination. Ask for the current GYFXTS datasheet, construction drawing and a written list of matched requirements, deviations and open confirmations.
CTA: Request the current GYFXTS datasheet and configuration review.
Frequently Asked Questions
What is the source-listed GYFXTS construction?
The supplied BWNFiber record identifies a PBT loose tube, E-glass-yarn strength member and steel-tape armor for a 1–12F cable with a nominal 8.0 mm diameter. The complete cross-section and model revision still require a controlled drawing.
Which fiber options are listed?
The source lists SM G.652, SM G.652.D, MM 50/125, MM 62.5/125 and MM OM3-300. Select one option for the quotation and ask BWNFiber to confirm the exact designation, availability and optical specification.
Can this cable be installed directly in soil?
The supplied source does not establish direct-burial approval. Steel-tape armor is a construction feature, not an installation declaration. Obtain the exact model’s declared use, water-protection evidence and route approval before specifying direct burial.
Is this a self-supporting aerial cable?
That is not proven by the supplied source. A self-supporting aerial design requires model-specific load and span evidence plus route and hardware engineering. Do not infer this use from the word outdoor.
What do 10D and 20D mean?
D is the finished cable diameter. The source lists 10D for long-term conditions and 20D for short-term conditions. BWNFiber should confirm the approved static/dynamic terminology and how the limit applies during handling and service.
Are the attenuation values guaranteed?
The page reports values recovered from the BWNFiber source record. The test method, sample condition and maximum/typical basis remain TBC, so the values should not be treated as a contractual guarantee until they appear in the approved datasheet or purchase specification.
Does E-glass yarn prove rodent resistance?
No such claim is supported by the supplied record. Ask for the intended function of the yarn and any model-specific test or application evidence before using an anti-rodent claim.
What information is missing for a complete cable approval?
The outer sheath, water-blocking design, crush values, steel-tape details, declared installation methods, test methods, certifications, packing and commercial terms still require controlled sources.
What documents should a buyer request?
Request the current model datasheet, revision-controlled construction drawing, declared-use statement, required model-traceable test records, deviation list, drum schedule and inspection/packing documents.
What should I include in the quotation request?
Include the route, selected fiber grade and count, total and per-drum lengths, mechanical/environmental requirements, cable marking, required documents, quantity, destination and requested delivery window.
Related Products