Outdoor Fiber Cable

GYFXTS 1-12F Glass-Yarn Steel-Tape Armored Outdoor Fiber Optic Cable

GYFXTS 1-12F Glass-Yarn Steel-Tape Armored Outdoor Fiber Optic Cable for outdoor plant use at 1-12F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

GYFXTS

Short Answer

The source-listed BWNFiber GYFXTS configuration is a compact 1–12-fiber outdoor cable built around a PBT loose tube, E-glass-yarn strength member and steel-tape armor. The source lists a nominal 8.0 mm cable diameter, 83 kg/km cable weight, multiple single-mode and multimode fiber options, and separate installation and service limits. These values remain subject to BWNFiber engineering confirmation because the underlying record contains sparse or merged cells.

Do not approve aerial, duct or direct-burial use from the words outdoor or armored alone. Ask for the current model-specific datasheet, construction drawing, declared installation methods and applicable test evidence before releasing a purchase order.

Primary action: Request the current GYFXTS datasheet and ask BWNFiber to review your route and selected configuration.

Technical Notice

The figures below are source-listed review values, not contractual guarantees. Confirm every value, condition and option against the current approved BWNFiber datasheet and quotation for the exact configuration.

Configuration at a Glance

Selection fieldSource-listed valueApproval status
ModelGYFXTSConfirm exact revision
Fiber count1–12FSelect one count; confirm availability
Fiber optionsSM G.652 / G.652.D; MM 50/125; MM 62.5/125; MM OM3-300Select one grade; confirm nomenclature and supply
Loose tubePBT, 2.8 ± 0.2 mmConfirm on controlled construction drawing
Strength memberE-glass yarnConfirm material, placement and function
ArmorSteel tapeTape type, coating and coverage: TBC
Overall cable diameter8.0 mm nominalDiameter tolerance: TBC
Cable weight83 kg/kmConfirm nominal value and tolerance
Outer sheathTBC — source requiredDo not infer PE, LSZH, UV or flame properties
Water-blocking systemTBC — source requiredDo not claim water resistance without evidence
Declared installation methodsTBC — source requiredAerial, duct and burial approval remain open

The model name is not a complete purchase specification. The quotation should identify one fiber count, one fiber grade, required length, length per drum or roll, marking, destination and the documents needed for approval.

Source-Listed Technical Specifications

Optical characteristics

Fiber optionWavelengthSource-listed attenuationStatus
SM G.6521310 / 1550 nm≤0.36 / 0.23 dB/kmTest method and maximum/typical basis: TBC
SM G.652.D1310 / 1550 nm≤0.36 / 0.23 dB/kmTest method and maximum/typical basis: TBC
MM 50/125850 / 1300 nm≤3.0 / 1.0 dB/kmExact grade and conditions: TBC
MM 62.5/125850 / 1300 nm≤3.0 / 1.0 dB/kmExact grade and conditions: TBC
MM OM3-300850 / 1300 nm≤3.0 / 1.0 dB/kmProduct naming and bandwidth evidence: TBC

ITU-T G.652 defines attributes for single-mode optical fiber and cable, but citing the Recommendation does not prove that a particular manufactured cable complies with it. Confirm the exact fiber designation on the controlled datasheet and purchase specification.

Mechanical and environmental values

ParameterSource-listed valueBuyer check
Minimum bend radius, long term10DConfirm whether the approved term is static; D is finished cable diameter
Minimum bend radius, short term20DConfirm whether the approved term is dynamic/installation
Tensile load, long term900 NTest method and acceptance criterion: TBC
Tensile load, short term1000 NTest method and acceptance criterion: TBC
Operating temperature-40 to +70 °CConfirm exact model/configuration
Installation temperature-20 to +60 °CConfirm handling and pulling conditions
Storage temperature-40 to +70 °CRecovered from sparse source; engineering review required
Crush resistanceTBC — source requiredRequired before route approval

IEC 60794-1-2 provides general guidance on optical-cable test procedures. It does not establish that this GYFXTS configuration was tested, passed a particular method or meets a project-specific limit. Request model-traceable test evidence when the purchase specification requires it.

What Must Be Confirmed Before Route Approval?

An outdoor cable decision starts with the physical route. Separate every aerial, duct, conduit, exposed, buried and building-entry segment. Then compare the route requirements with one controlled model revision.

Use the fiber optic cable selection guide to define the cable family, and the armored vs direct-burial route approval guide to keep construction features separate from installation declarations.

Hold approval until the following questions are closed:

  1. What installation methods does the exact model declare? The current source does not prove self-supporting aerial, duct, direct-burial or indoor use.
  2. What is the complete cross-section? Confirm tube filling, water-blocking layers, steel-tape construction, ripcord and outer sheath.
  3. Which mechanical limits apply? Confirm tensile, crush, impact and bend limits with long/short-term conditions and the applicable test method.
  4. How will metallic armor be handled? The project owner must define any grounding, bonding, isolation and termination requirements.
  5. Does the cable fit every interface? Match the confirmed diameter and tolerance to ducts, glands, closures, seals, clamps and pulling equipment.
  6. What happens at a building entry? Outdoor suitability does not establish a building fire or smoke rating. Confirm the transition point and local requirements.
  7. Which documents control the order? Use a revision-controlled datasheet, construction drawing, agreed deviation list and quotation tied to the same configuration.

How to Select the Correct GYFXTS Configuration

Define the route and network role

State whether the cable will be used in an access, distribution, backbone or another link. Mark each installation segment and identify pulling distance, bends, water exposure, mechanical loading, entries and splice locations.

For family-level discovery, compare the published outdoor fiber optic cable range. For execution planning, review the separate fiber optic cable installation guide.

Select one fiber grade and one count

Choose the fiber grade from the active equipment, wavelength, reach, link budget and project requirements. Then select the working-fiber count plus any project-approved reserve. Do not combine every fiber option shown on this page into one order description.

Convert route risks into cable requirements

Record required tensile and crush limits, bend conditions, sheath properties, water-blocking expectations, temperature ranges, armor treatment, dimensions and document requirements. If any requirement is absent from the controlled model evidence, list it as an open deviation.

Match interfaces and logistics

Confirm closure and gland ranges, drum access, pulling direction, planned splice points, reel length, cable marking and destination. A nominal 8.0 mm diameter is not sufficient for interface approval until its tolerance is confirmed.

Approve documents before the purchase order

Ask BWNFiber to return the current datasheet, construction drawing, configuration confirmation and a written response to every required document or test item. Any alternative should be rechecked rather than accepted as an unspecified equivalent.

How This Page Differs From Related BWNFiber Pages

Page or familyIntended ownerKey distinctionLink role
GYFXTS 1–12F (this page)Exact GYFXTS configuration and RFQSource lists E-glass yarn, steel tape and nominal 8.0 mm diameterExact-model validation
2–12F central loose-tube armored pagePublished GYXTW 2–12F configurationLive page identifies two parallel steel wires and different mechanical valuesCompare strength-member construction
2–24F central loose-tube armored pageWider central-loose-tube rangeLive page identifies Kevlar, steel tape and different dimensions/valuesCompare fiber-count range and controlled model
Armored / Direct Burial Cable guideBroad route selectionExplains why armored and direct-burial are not interchangeableRoute-approval education
Outdoor Fiber Optic Cable categoryOutdoor family discoveryBroad family and installation-route selectionParent category

This table defines page roles; it does not claim that one construction performs better. A controlled datasheet and route requirements are needed for a technical comparison.

Required Information for an RFQ

Send one complete requirement set:

  • Product/model: GYFXTS, with the required revision or approved construction
  • Installation route: each aerial, duct, conduit, exposed, buried and indoor segment
  • Network role and link length
  • Fiber grade and exact fiber count
  • Required attenuation or link-budget conditions and acceptance wavelengths
  • Required tensile, crush, bend, impact and temperature limits
  • Outer-sheath, water-blocking and metallic-armor requirements
  • Total cable length and length per drum or roll
  • Drum access, pulling direction and planned splice locations
  • Cable marking, language and packaging requirements
  • Required datasheet, drawing, test records, certificates and inspection documents
  • Quantity, destination and requested delivery window

Price, MOQ, availability and lead time are TBC — controlled quotation required.

Datasheet, Drawing and Test-Report Area

  • Current GYFXTS datasheet: TBC — source required
  • Revision-controlled construction drawing: TBC — source required
  • Declared installation-method statement: TBC — source required
  • Model-specific test report or inspection plan: TBC — source required
  • Packing and drum-length specification: TBC — source required

Do not display download buttons until the files exist, match the exact model and have release approval.

Request a GYFXTS Configuration Review

Send BWNFiber your route drawing or route description, selected fiber grade and count, required lengths, mechanical and environmental requirements, document list, quantity and destination. Ask for the current GYFXTS datasheet, construction drawing and a written list of matched requirements, deviations and open confirmations.

CTA: Request the current GYFXTS datasheet and configuration review.

FAQ

Frequently Asked Questions

What is the source-listed GYFXTS construction?

The supplied BWNFiber record identifies a PBT loose tube, E-glass-yarn strength member and steel-tape armor for a 1–12F cable with a nominal 8.0 mm diameter. The complete cross-section and model revision still require a controlled drawing.

Which fiber options are listed?

The source lists SM G.652, SM G.652.D, MM 50/125, MM 62.5/125 and MM OM3-300. Select one option for the quotation and ask BWNFiber to confirm the exact designation, availability and optical specification.

Can this cable be installed directly in soil?

The supplied source does not establish direct-burial approval. Steel-tape armor is a construction feature, not an installation declaration. Obtain the exact model’s declared use, water-protection evidence and route approval before specifying direct burial.

Is this a self-supporting aerial cable?

That is not proven by the supplied source. A self-supporting aerial design requires model-specific load and span evidence plus route and hardware engineering. Do not infer this use from the word outdoor.

What do 10D and 20D mean?

D is the finished cable diameter. The source lists 10D for long-term conditions and 20D for short-term conditions. BWNFiber should confirm the approved static/dynamic terminology and how the limit applies during handling and service.

Are the attenuation values guaranteed?

The page reports values recovered from the BWNFiber source record. The test method, sample condition and maximum/typical basis remain TBC, so the values should not be treated as a contractual guarantee until they appear in the approved datasheet or purchase specification.

Does E-glass yarn prove rodent resistance?

No such claim is supported by the supplied record. Ask for the intended function of the yarn and any model-specific test or application evidence before using an anti-rodent claim.

What information is missing for a complete cable approval?

The outer sheath, water-blocking design, crush values, steel-tape details, declared installation methods, test methods, certifications, packing and commercial terms still require controlled sources.

What documents should a buyer request?

Request the current model datasheet, revision-controlled construction drawing, declared-use statement, required model-traceable test records, deviation list, drum schedule and inspection/packing documents.

What should I include in the quotation request?

Include the route, selected fiber grade and count, total and per-drum lengths, mechanical/environmental requirements, cable marking, required documents, quantity, destination and requested delivery window.

Related Products