GYFXBY
GYFXBY 2-12F 100m Span Flat All-Dielectric Aerial Fiber Optic Cable
GYFXBY 2-12F 100m Span Flat All-Dielectric Aerial Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Product Value Summary
The BWNFiber GYFXBY configuration on this page is a flat, all-dielectric aerial fiber optic cable for 2-12 fibers. The supplied record lists a 4.2 × 7.8 mm cable profile, 35 kg/km nominal weight, a source-labeled MAT value of 1500 N, 1000 N/100 mm crush resistance, a PE sheath and a 100 m span designation. Keep these values together as one configuration; do not substitute figures from another GYFXBY, FTTH drop-cable or ADSS family table.
Short Answer for Buyers
Use this page to prepare an RFQ for the specified GYFXBY 2-12F configuration—not to approve an aerial route from the model name alone. State the fiber count, route and span schedule, cable length, drum length, installation hardware, environmental loads, marking and required documents. A 100 m product designation still requires confirmation against the actual wind, ice, sag, attachment, clearance and hardware conditions.
GYFXBY 2-12F Configuration at a Glance
| Approval field | Supplied value | Release status |
|---|---|---|
| Product family | GYFXBY | Confirm controlled model code |
| Fiber count | 2-12F | Source-supported; select one count for the RFQ |
| Declared span | 100 m | TBC — confirm design basis and route applicability |
| Construction | Flat, all-dielectric aerial cable | Source-supported description |
| Cable profile | 4.2 × 7.8 mm | TBC — engineering review of F0661 table alignment |
| Cable weight | 35 kg/km | TBC — engineering review of F0661 table alignment |
| MAT | 1500 N | TBC — confirm label definition and applicable condition |
| Crush resistance | 1000 N/100 mm | TBC — confirm test condition and source-table alignment |
| Outer sheath | PE | Source-supported; no fire, UV or compliance rating inferred |
Key Features
- 2-12F configuration range.
- Flat cable profile listed as 4.2 × 7.8 mm.
- All-dielectric construction with two source-listed FRP elements.
- PE outer sheath.
- Source-listed 100 m span designation.
- Loose-tube fiber protection.
These are identification and comparison fields. They do not replace a route calculation, controlled drawing, test method or project approval.
Cable Construction and Dimensions
| Component or parameter | Supplied specification | Buyer check |
|---|---|---|
| Fiber count | 2-12F | Choose the exact count; do not order the range as one configuration |
| Cable type | GYFXBY-nB1.3 | TBC — confirm the exact orderable model code |
| Declared application | FTTH / aerial installation | Confirm whether the route is a subscriber drop, distribution link or another aerial segment |
| Loose-tube size | 2 mm | TBC — confirm whether this is outside diameter and the applicable tolerance |
| FRP size | 2 × 1.8 mm | TBC — confirm whether 1.8 mm is the diameter of each FRP element |
| Cable size | 4.2 × 7.8 mm | Check clamps, seals, entry ports, bend path and installation tools |
| Cable weight | 35 kg/km | Use the confirmed value in sag/tension and logistics review |
| Outer sheath | PE | Do not infer UV, flame, smoke, halogen or certification status from “PE” alone |
Optical Characteristics
The supplied record lists the following cabled-fiber values. They are not a complete installed-link loss budget and do not include splice, connector, splitter or engineering margin.
| Parameter / condition | Supplied specification | Status |
|---|---|---|
| Mode field diameter at 1310 nm | 9.2 ± 0.4 μm | TBC — confirm fiber grade and source revision |
| Cladding diameter | 125 ± 1 μm | TBC — confirm source revision |
| Core concentricity error | ≤0.6 μm | TBC — confirm source revision |
| Cladding non-circularity | ≤1.0% | TBC — confirm source revision |
| Cable cut-off wavelength | ≤1260 nm | TBC — confirm source revision |
| Fiber cut-off wavelength | 1180-1330 nm | TBC — confirm source revision |
| Primary coating diameter, excluding color layer | 245 ± 10 μm | TBC — confirm source revision |
| Primary coating diameter, including color layer | 250 ± 15 μm | TBC — confirm source revision |
| Coating-cladding concentricity error | ≤12.5 μm | TBC — confirm source revision |
| Fiber curl radius | ≥4 m | TBC — confirm source revision |
| Attenuation at 1310 nm | ≤0.36 dB/km maximum | TBC — confirm fiber grade and acceptance method |
| Attenuation at 1550 nm | ≤0.21 dB/km maximum | TBC — confirm fiber grade and acceptance method |
| Chromatic dispersion, 1288-1339 nm | ≤3.5 ps/(nm·km) | TBC — confirm source revision |
| Chromatic dispersion at 1550 nm | ≤17 ps/(nm·km) | TBC — confirm source revision |
| Zero-dispersion wavelength | 1300-1324 nm | TBC — confirm source revision |
| Zero-dispersion slope | ≤0.092 ps/(nm²·km) | TBC — confirm source revision |
| Macrobending-loss condition | Φ 60 mm, 100 turns at 1550 nm: ≤0.1 dB | TBC — treat as a stated fiber test condition, not the finished-cable installation bend radius |
The optical attributes align with the types of attributes addressed by ITU-T G.652, but this draft does not claim compliance until the controlled BWNFiber source identifies the fiber grade and applicable standard.
Mechanical and Environmental Limits
| Parameter | Supplied specification | Approval note |
|---|---|---|
| MAT | 1500 N | TBC — confirm definition, duration and design use |
| Crush resistance | 1000 N/100 mm | TBC — confirm method, duration and acceptance condition |
| Minimum bend radius, dynamic | 20 × cable diameter | Apply during installation only after engineering confirmation |
| Minimum bend radius, static | 10 × cable diameter | Apply in service only after engineering confirmation |
| Operating temperature | -30°C to +60°C | Do not substitute for installation or storage limits |
| Installation temperature | -30°C to +60°C | Confirm handling procedure and project conditions |
| Storage temperature | -40°C to +70°C | Confirm packaging and storage instructions |
IEC 60794-3-20 covers self-supporting aerial telecommunication cable as a cable with sufficient strength members to be suspended without another supporting wire. It does not prove that this BWNFiber configuration complies with that standard; compliance and test-method claims remain TBC — source required.
Application and Approval Boundaries
This configuration may be evaluated for an outdoor aerial FTTH or access/distribution route where an all-dielectric flat cable is required. Final suitability depends on the exact role of the cable and the route inputs.
Do not release the model until the project owner or qualified engineer has reviewed:
- Every span, including the longest and ruling spans.
- Wind, ice, temperature and any other governing load case.
- Sag, attachment height, ground and utility clearances.
- Clamp, suspension and dead-end hardware compatibility with the 4.2 × 7.8 mm profile.
- Cable tension during installation and in service.
- Bend control at poles, closures, entries and storage points.
- The transition from the aerial section to the building or enclosure.
- The exact fiber grade, count, color code and acceptance criteria.
Interfaces and Connector Options
The supplied record describes bulk cable and does not identify connectorized ends.
- End A: TBC — unterminated or connectorized
- End B: TBC — unterminated or connectorized
- Connector type and polish: TBC — source required
- Splice closure, terminal, gland, seal and clamp interfaces: TBC — project-specific
Do not add LC, SC, APC, UPC or hardened-interface claims unless they are part of the confirmed order configuration.
Fiber Type and Configuration Options
- Fiber count: select one value from 2-12F.
- Fiber grade: TBC — source required. The internal source-path name references G.652.D, but the controlled datasheet or engineering approval must confirm the page claim.
- Color code: TBC — source required.
- Tube-filling or water-blocking construction: TBC — source required.
How to Select the Correct Configuration
- Define the network job: subscriber drop, access distribution or another aerial segment.
- Provide the complete span schedule and governing environmental loads.
- Select the exact fiber count and confirm the fiber grade.
- Confirm the 4.2 × 7.8 mm profile against clamps, seals, entries and storage hardware.
- Review MAT, crush, bend and temperature limits as one configuration.
- Specify cable length, length per drum, marking, packaging and quantity.
- List the documents needed for technical approval and receiving inspection.
Differences from Related BWNFiber Pages
| Page | It should own | This GYFXBY page should own |
|---|---|---|
| FTTH Drop Cable category | Broad construction comparison and route selection | One exact GYFXBY configuration |
| Aerial Self-support FTTH Drop Cable | Broader family and alternative strength-member/count options | GYFXBY, 2-12F, 100 m designation, 4.2 × 7.8 mm, source-linked limits |
| ADSS Cable category | Engineered ADSS route selection by span, MAT, RTS, load case and hardware | This exact flat cable only; do not target broad ADSS selection intent |
| GYFXBY-1F test-batch page | Evidence for one identified 1F production/test batch | 2-12F family specification; do not inherit the batch results |
Testing and Quality-Control Process
The source provides product values but does not provide a complete approved inspection and test plan for publication.
Required evidence before this module can be released:
- Controlled datasheet and revision.
- Engineering-approved cross-section drawing.
- Fiber-grade certificate or approved specification.
- Mechanical test methods, conditions and acceptance criteria for tension and crush.
- Optical acceptance method and wavelength limits for the delivered configuration.
- Lot/reel traceability and test-record format.
- Any claimed standard or certification with scope and current document.
Status: TBC — source required. No test-performance claim is made in this draft.
Packaging and Procurement Information
| Field | RFQ entry |
|---|---|
| Exact model / revision | TBC |
| Fiber count | ___ F (choose 2-12F) |
| Fiber grade | TBC |
| Route and span schedule | ___ |
| Total cable length | ___ m / km |
| Length per drum | ___ m |
| Quantity | ___ drums / ___ km |
| Cable marking | ___ |
| Drum/packing requirement | TBC |
| Delivery destination | ___ |
| Required documents | Datasheet / drawing / test record / certificate: ___ |
MOQ, price, stock, production lead time, warranty and standard drum length are TBC — commercial confirmation required.
Required Information for an RFQ
Send BWNFiber:
- “GYFXBY 2-12F 100 m Span Flat All-Dielectric Aerial Fiber Optic Cable” as the reference description.
- Exact fiber count and confirmed fiber grade.
- Route drawing and complete span schedule.
- Wind, ice, temperature, clearance and attachment requirements.
- Clamp and hardware references, if already selected.
- Total length, drum lengths, quantity and marking.
- Required datasheet, drawing, inspection and test evidence.
- Delivery destination and requested commercial terms.
Datasheet, Drawing and Test-Report Area
- Controlled datasheet: TBC — source required
- Cross-section drawing: TBC — engineering-approved source required
- Mechanical test evidence: TBC — source required
- Optical test evidence: TBC — source required
- Certificate/standard scope: TBC — source required
Frequently Asked Questions
What is the product covered by this page?
This draft covers one GYFXBY flat, all-dielectric aerial cable configuration for 2-12 fibers with a source-listed 100 m span designation and a 4.2 × 7.8 mm profile. It does not cover every GYFXBY cable or every aerial route.
Which fiber count should be included in the order?
Select one count from 2-12F. State the chosen count in the model description, drawing, quotation and purchase order so a family range is not treated as a released part number.
Is a 100 m span designation enough to approve the route?
No. Confirm the complete span schedule, sag, wind, ice, temperature, attachment, clearances and compatible hardware. The 100 m label is a product-selection input, not a route approval.
Is this cable metallic?
The supplied configuration is described as all-dielectric and lists FRP elements. Confirm the controlled drawing before release; do not infer electrical-clearance approval from the phrase “all-dielectric.”
What cable dimensions should the clamps and entries match?
The supplied table lists 4.2 × 7.8 mm. F0661 table 3 still needs engineering confirmation, so match hardware only after the dimension and tolerance are approved.
What bend-radius limits are listed?
The supplied record lists 20 times the cable diameter for dynamic bending and 10 times the cable diameter for static bending. These finished-cable limits are separate from the 60 mm, 100-turn macrobending test condition listed for the fiber.
What attenuation values are listed?
The supplied record lists maximum attenuation of 0.36 dB/km at 1310 nm and 0.21 dB/km at 1550 nm. Confirm the fiber grade, source revision and acceptance method before using them in a specification. They are not a complete link-loss budget.
Does a PE sheath prove UV, flame or low-smoke performance?
No. “PE” identifies the source-listed sheath material. UV resistance, flame behavior, smoke/halogen classification and other compliance claims require separate evidence for the exact cable.
What test records should a buyer request?
Request the controlled datasheet and drawing first, then define the required optical and mechanical acceptance evidence for the exact order and lot. The current source does not support a published universal test package.
What should be sent for an accurate quotation?
Send the exact fiber count and grade, route and span schedule, environmental loads, hardware, total and drum lengths, quantity, marking, delivery destination and required approval documents.
Related Products