GYFTZY
GYFTZY 144F 13.4mm Water-Blocking Loose Tube PE Fiber Optic Cable
GYFTZY 144F 13.4mm Water-Blocking Loose Tube PE Fiber Optic Cable for outdoor plant use at 144F. Confirm model, fiber count and installation method against the source drawing.

Product value summary
This page describes one 144-fiber configuration: G.652.D fiber, a black PE outer sheath and a listed overall diameter of 13.4±0.5 mm. The internal record also identifies PBT loose tubes and an FRP member. Confirm the approved model code, construction drawing, installation method and mechanical limits before using this configuration in a project specification or purchase order.
Short buyer answer
Use this configuration only when the approved BWNFiber datasheet matches the required 144F count, G.652.D grade, PE sheath, cable diameter and route conditions. Do not substitute family-level GYFTY/GYFTZ data or competitor values. For quotation review, send the route type, total length, drum plan, entry or clamp limit, marking text, quantity and destination.
Verified-to-date configuration table
| Attribute | Controlled draft value | Release state |
|---|---|---|
| Product model | GYFTZY | TBC — conflicts with GYFTY source filename and GYFTZ live URL |
| Fiber count | 144F | Internal record; engineering approval required |
| Fiber grade | G.652.D | Internal record; engineering approval required |
| Outer sheath | PE, black | Internal record; no fire/UV classification inferred |
| Listed overall diameter | 13.4±0.5 mm | Internal record; drawing approval required |
| Water-blocking components | Water-blocking yarn and tape | Internal record; dry/gel-free claim prohibited |
| Loose tube | PBT, 2.0±0.1 mm | Internal record; drawing approval required |
| Non-metal member | FRP, 2.0 mm | Internal record; function/coating TBC |
| Cable weight | 140±10 — unit unresolved | do not use for order release |
Optical characteristic scoped to the selected fiber
| Fiber grade | Wavelengths | Draft attenuation limit | Release state |
|---|---|---|---|
| G.652.D | 1310 / 1550 nm | ≤0.34 / 0.22 dB/km | Internal record; QA/engineering confirmation required |
Remove the G.652, MM 50/125, MM 62.5/125, OM3-300, and OM3-550 rows from this exact G.652.D configuration. They are alternatives from a broader source table, not simultaneous attributes of this product.
Interfaces and connector options
This is presented as bulk fiber optic cable, not a terminated cable assembly. Connector, polish, and end-face options are therefore not applicable unless BWNFiber confirms a separate terminated assembly offer.
Compatibility and application conditions
- Match the approved overall cable diameter to the duct, gland, closure entry, pulling equipment, or clamp selected for the route.
- Confirm whether the cable is approved for duct, non-self-supporting aerial, direct-burial, or another installation method. The current evidence does not establish this.
- Obtain approved tensile, crush, bend-radius, storage, operating, and installation limits before route design or installation.
- Do not infer flame retardance, LSZH performance, UV resistance, rodent resistance, lightning safety, or standards compliance from the model name or PE material alone.
How to select the correct configuration
- Confirm the approved model code and 144F construction drawing.
- Confirm G.652.D as the required fiber grade and obtain the applicable optical specification.
- Check the route type and all mechanical/environmental limits against the project specification.
- Check the approved overall diameter against every entry, clamp, duct and closure interface.
- Define total length, length per drum, quantity, cable marking and destination.
- Request the current datasheet, drawing and available quality documents before issuing the purchase order.
Difference from related products
| Related page/family | Intended role | Required distinction |
|---|---|---|
| GYFTY family | Broad non-metallic loose-tube PE family | Owns family/count selection if the source filename is authoritative |
| GYFTZ family | Existing live BWNFiber product owner | Owns the current canonical unless catalog governance changes it |
| GYTS | Steel-tape armored family | Separate armored construction; do not merge its mechanical/application claims |
| Exact 144F module | One orderable configuration | Should add only verified 144F-specific facts under the canonical owner |
Testing and quality-control process
TBC — source required. Do not claim test methods, equipment, ranges, results, standards compliance, 100% testing, OTDR acceptance, insertion loss, return loss, or certificates until BWNFiber QA supplies the applicable procedure and document set for this cable.
Packaging and procurement information
TBC — source required. Confirm reel/drum type, standard and maximum continuous length, length tolerance, net/gross weight, dimensions, marking format, MOQ, lead time and export-packaging options before publication or quotation.
RFQ checklist
- Approved product model and revision
- 144F and G.652.D requirement
- Required route / installation method
- Total cable length
- Required length per drum
- Quantity of drums
- Entry, duct, clamp or closure diameter constraint
- Required cable marking and meter marking
- Required datasheet, drawing, test/inspection or compliance documents
- Delivery destination and requested Incoterm, if applicable
Primary CTA: Send the approved model, route type, total length, drum plan, marking and destination for a configuration review and quotation.
Datasheet / drawing / test-report area
- Approved product datasheet:
TBC — source required - Approved construction drawing:
TBC — source required - Routine/type test document list:
TBC — source required - Cable marking sample:
TBC — source required
Visible FAQ candidates
Is GYFTZY the confirmed model for this 144F cable?
Not yet. The supplied records conflict between GYFTY, GYFTZ and GYFTZY. BWNFiber product engineering must approve the model before this page or an RFQ uses it.
Which fiber grade is associated with this draft configuration?
The internal draft associates the 144F configuration with G.652.D. The approved datasheet must confirm the grade and its optical limits before publication or purchase.
What does 13.4±0.5 mm describe?
It is listed as the overall cable diameter in the internal draft. It is not the loose-tube or FRP-member diameter. Confirm it against the approved drawing before checking entry or clamp fit.
Is this a dry or gel-free cable?
The available draft identifies water-blocking yarn and tape, but it does not provide a complete BOM or cross-section. Do not describe the cable as dry or gel-free until engineering confirms the entire water-blocking system.
Is this cable flame-retardant or LSZH?
No fire classification or LSZH evidence was supplied. A black PE sheath name alone does not prove a flame, smoke or halogen classification.
Can this cable be installed in duct, aerial routes, or direct burial?
The current evidence does not establish a permitted installation method. Send the route conditions to BWNFiber and obtain the approved application statement and mechanical limits.
Which mechanical limits should be used?
Tensile, crush and bend-radius limits are TBC. Do not use competitor or family-level values for this exact configuration.
What optical rows belong on this page?
Only the approved G.652.D values should remain on an exact G.652.D configuration page. Multimode and other single-mode alternatives belong to a family selector or separate configurations.
What information is required for a quotation?
Send the approved model, route type, total length, length per drum, quantity, diameter constraints, marking, required documents and delivery destination.
Which documents should be reviewed before ordering?
Request the current datasheet and construction drawing, then ask which inspection, test and compliance documents are available for the exact order configuration.
Related Products