GYFTZ Cable at a Glance
The proposed BWNFiber GYFTZ page covers a stranded loose-tube cable family listed with an LSZH outer sheath and fiber-count bands from 2 to 216 fibers. The supplied record also lists PBT loose tubes, an FRP central strength member, water-blocking tape and single-mode or multimode fiber options.
Before using these values in a design, purchase order or tender, request the approved specification for the exact fiber count. BWNFiber engineering must confirm the model code, count range, fiber grade, finished-cable dimensions, installation route, mechanical limits, jacket classification and required test documents.
Primary CTA: Request the approved GYFTZ datasheet and configuration review.
Short Answer for Buyers
GYFTZ is presented in the supplied BWNFiber record as a 2–216F stranded loose-tube cable with an LSZH sheath, PBT tube elements, an FRP central strength member and water-blocking tape. Select one fiber-count row and one fiber grade, then confirm the proposed route, cable OD, pulling/crush limits, drum schedule and required evidence before quotation. The current record contains unresolved model and scope conflicts, so no configuration should be released from this draft alone.
Key Configuration Points
- Fiber-count bands: 2–30F, 32–60F, 62–72F, 74–96F, 98–120F, 122–144F and 146–216F — source-provisional.
- Fiber options: single-mode or multimode — exact grades and optical matrix require confirmation.
- Loose-tube/filler material: PBT — source-provisional.
- Central strength member: FRP, listed as 1.4–2.0 mm ±0.2 mm — source-provisional.
- Outer sheath: LSZH, listed as 1.6±0.2 mm — confirm that this value is sheath thickness and not finished-cable diameter.
- Moisture barrier: water-blocking tape — source-provisional.
- Installation route: TBC — source required. Do not infer aerial, duct, direct-buried, tunnel or indoor suitability from the product name alone.
- Fire/smoke/halogen classification: TBC — test standard and report required.
Cable Construction
| Component | Source-provisional value | Release status |
|---|---|---|
| Fiber-count family | 2–216F in count bands | TBC: conflicts with a separate 2–144 cores row |
| Fiber type | Single-mode or multimode | TBC: exact grade per order required |
| Loose-tube and filler material | PBT | TBC: confirm finished BOM |
| Loose-tube/filler diameter | Φ1.6–2.2 mm ±0.2 mm | TBC: confirm notation and applicable count rows |
| Central strength member | FRP | TBC: confirm whether the entire cable is all-dielectric |
| Central strength-member diameter | 1.4–2.0 mm ±0.2 mm | TBC: confirm configuration mapping |
| Outer sheath material | LSZH | TBC: compound and test classification required |
| Outer-sheath value | 1.6±0.2 mm | TBC: confirm that this is sheath thickness |
| Moisture barrier | Water-blocking tape | TBC: confirm full water-blocking construction |
Count-Dependent Configuration Matrix
Do not combine values from different rows. The selected count band must remain tied to its diameter, weight, tube/filler count and mechanical limits.
| Fiber count | Nominal cable diameter | Nominal weight | Max. fibers per tube | Tubes + fillers | Tensile, short/long term | Crush, short/long term | Status |
|---|---|---|---|---|---|---|---|
| 2–30F | 7.80±0.5 mm | 60±5 kg/km | 6 | 5 | 1500/600 N | 1000/300 N per 100 mm | TBC — source sign-off |
| 32–60F | 8.60±0.5 mm | 65±5 kg/km | 12 | 5 | 1500/600 N | 1000/300 N per 100 mm | TBC — source sign-off |
| 62–72F | 9.20±0.5 mm | 100±5 kg/km | 12 | 6 | 1500/600 N | 1000/300 N per 100 mm | TBC — source sign-off |
| 74–96F | 11.0±0.5 mm | 130±5 kg/km | 12 | 8 | 1500/600 N | 1000/300 N per 100 mm | TBC — source sign-off |
| 98–120F | 13.2±0.5 mm | 160±5 kg/km | 12 | 10 | 1500/600 N | 1000/300 N per 100 mm | TBC — source sign-off |
| 122–144F | 13.40±0.5 mm | 204±5 kg/km | 12 | 12 | 1800/600 N | 1000/300 N per 100 mm | TBC — source sign-off |
| 146–216F | 16.0±0.5 mm | 205±5 kg/km | 12 | 18, two layers | 1800/600 N | 1000/300 N per 100 mm | TBC — source sign-off |
Engineering review required: Confirm test methods, duration, units, tolerances and whether all rows belong to the same LSZH product family.
Optical Options
The supplied V4 associates the following attenuation rows with this family. These values must not be published until the original table and its measurement conditions are approved.
| Fiber option | Wavelength | Source-provisional attenuation | Release status |
|---|---|---|---|
| SM G.652.D | 1310/1550 nm | ≤0.34/0.22 dB/km | TBC — confirm grade and conditions |
| MM 50/125 | 850/1300 nm | ≤3.0/1.0 dB/km | TBC — confirm grade and conditions |
| MM 62.5/125 | 850/1300 nm | ≤3.0/1.0 dB/km | TBC — confirm grade and conditions |
The source review also flags unresolved dispersion-slope, PMD and numerical-aperture fields. Do not add standard values from competitor pages or general references.
Mechanical and Environmental Limits
| Condition | Source-provisional value | Required confirmation |
|---|---|---|
| Installation temperature | −15°C to +60°C | Test/source revision and applicable configurations |
| Operation and transport temperature | −40°C to +70°C | Separate storage, transport and operating limits if they differ |
| Minimum bend radius, long term | 10 × cable diameter | Confirm terminology: installed/no-load condition |
| Minimum bend radius, short term | 20 × cable diameter | Confirm terminology: installation/under-load condition |
These limits do not establish route suitability by themselves. Confirm pulling method, duct or tray dimensions, entry hardware, environmental exposure and local code requirements for the actual project.
How to Select the Correct Configuration
- Confirm the model code. Ask BWNFiber to verify that GYFTZ is the correct designation for the requested construction and sheath.
- Select one fiber count. Use the corresponding row for cable diameter, weight, tube/filler count and mechanical limits.
- Specify one fiber grade. Do not combine single-mode and multimode values in one order line.
- Describe the route. State whether the planned route is duct, tray, tunnel, riser, aerial, direct-buried or another environment. BWNFiber must confirm suitability; this page does not.
- State fire and material requirements. If LSZH, flame spread, smoke, halogen, UV or another property is mandatory, identify the required standard and classification.
- Confirm installation constraints. Include maximum pulling load, bend path, duct/gland size and any handling limits required by the project.
- Define the drum schedule. State total quantity, length per drum, acceptable tolerance, marking text and destination.
- List required documents. Request the approved datasheet, drawing and applicable test/inspection documents before PO release.
Differences from Related BWNFiber Drafts
| Related model/page | Supplied difference | Buyer decision | Evidence gate |
|---|---|---|---|
| GYFTY 2–216F PE | PE sheath is listed instead of LSZH; most mechanical rows are otherwise the same | Choose only after route, jacket and product-code requirements are confirmed | Verify that these are separate, orderable families and not duplicate records |
| GYFTY 2–144F all-dielectric | Different count scope and catalog matrix | Use its exact catalog row when that source is the project match | Confirm the all-dielectric claim and model-code relationship |
| GYFTZY 144F | Fixed 144F configuration in the local draft | Use only if its exact 144F record is approved | Its source file/table identity is already flagged as conflicted |
| GYTZS 24–144F | Local draft lists corrugated steel tape | Use when the approved armored construction is required | Resolve the local page’s LSZH title versus PE/HDPE table conflict |
| GYXTZW 2–16F | Central loose tube with two steel wires and a lower count range | Use for the exact approved central-tube/dual-wire requirement | Resolve its LSZH title versus PE table conflict |
Applications and Compatibility Conditions
Verified application statement available in V4: outdoor fiber access and distribution.
That wording is too broad for final design approval. Before publication and quotation, BWNFiber must define:
- permitted installation routes;
- indoor/outdoor transition conditions;
- UV/weather exposure limits;
- water-blocking and water-penetration requirements;
- metallic/non-metallic status of the complete cable;
- flame/smoke/halogen classification;
- local code and project-standard compatibility;
- hardware, duct, gland and closure fit based on finished cable OD.
No compatibility with a brand, connector, enclosure, installation method or standard is claimed in this draft.
Testing and Quality-Control Requirements
No product-specific test method or test-report availability was supplied. For a project RFQ, identify which evidence is required and ask BWNFiber to confirm availability:
| Evidence/request | Why the buyer may need it | Current status |
|---|---|---|
| Approved product datasheet with revision | Locks the ordered configuration | TBC — source required |
| Cable cross-section or construction drawing | Confirms layers, materials and dimensions | TBC — source required |
| Fiber-grade certificate/data | Confirms the ordered optical fiber | TBC — source required |
| Finished-cable attenuation record | Confirms the agreed optical acceptance basis | TBC — method/availability required |
| Tensile/crush/bend test reference | Gives context to mechanical limits | TBC — method/availability required |
| Jacket/fire/smoke/halogen report | Supports any LSZH or flame classification | TBC — standard/classification required |
| Drum-length and marking inspection | Confirms delivery configuration | TBC — inspection process required |
Do not imply that all reports are included with every order. Availability, scope, sample size and acceptance criteria must be agreed in the quotation or quality plan.
Packaging and Procurement Information
| Item | Draft value/status |
|---|---|
| Standard drum length | 2 km — source-provisional; confirm tolerance and availability |
| Alternative drum length | TBC — source required |
| Drum type/dimensions | TBC — source required |
| Minimum order quantity | TBC — source required |
| Lead time | TBC — source required |
| Cable marking | Buyer should provide required text; format/limits TBC |
| Export packaging | TBC — source required |
| Warranty | TBC — source required |
Information Required for an RFQ
Send the following in one request:
- product code: GYFTZ, subject to BWNFiber confirmation;
- exact fiber count;
- exact fiber grade;
- proposed installation route and environment;
- required LSZH/flame/smoke/halogen standard and classification, if applicable;
- total cable length and quantity;
- required length per drum and acceptable tolerance;
- cable marking text;
- destination country and delivery location;
- required datasheet, drawing, test report, inspection or tender documents;
- any duct, gland, closure, pulling-load or bend-path constraints;
- target delivery date for quotation planning, without assuming a guaranteed lead time.
Primary CTA: Request an approved GYFTZ configuration and quotation.
Secondary CTA: Ask for the current datasheet and construction drawing.
Datasheet, Drawing and Test-Report Area
| Document | Status/action |
|---|---|
| Approved GYFTZ datasheet | TBC — source required |
| Approved construction drawing | TBC — source required |
| Count-specific dimensional table | TBC — engineer must sign off the supplied matrix |
| Optical-fiber data | TBC — confirm selected grade |
| Mechanical/environmental test references | TBC — source required |
| LSZH or flame/smoke/halogen evidence | TBC — source required |
Frequently Asked Questions
Is GYFTZ the correct model code for this LSZH cable?
The supplied BWNFiber V4 labels the product GYFTZ, but the local product set also contains closely related GYFTY and GYFTZY records. Confirm the model code and approved construction with BWNFiber engineering before using it in a tender or purchase order.
Does this page cover every fiber count from 2 to 216?
The supplied matrix contains seven count bands from 2–30F through 146–216F. A separate construction row says 2–144 cores, so the upper range is not cleared for publication. Request the approved count list for the exact model revision.
Which cable diameter applies to my order?
Use only the row for the selected fiber-count band. Do not use the sheath-thickness value as finished cable OD, and do not combine the diameter or weight from another count band.
Can I order single-mode or multimode fiber?
The supplied record lists both as alternatives. State one exact fiber grade in the RFQ and request the approved optical data for that grade. Do not apply all listed attenuation values to one cable.
Does LSZH prove that this cable meets my fire code?
No. The material label alone does not establish a specific flame, smoke, halogen or building-code classification. State the required standard and classification, then request the applicable evidence for the offered configuration.
Is the cable all-dielectric?
The supplied record lists an FRP central strength member, but a complete bill of materials was not provided. Do not claim all-dielectric construction until BWNFiber confirms that the finished cable contains no metallic elements.
Can this cable be installed in ducts, tunnels, aerial routes or direct burial?
The current record only says outdoor access and distribution. Give BWNFiber the exact route and environment so engineering can confirm suitability. Competitor application claims must not be used as evidence for this product.
What bend limits should the installer use?
The source-provisional record lists 20D short term and 10D long term, where D is cable diameter. Confirm the approved terminology and values for the ordered configuration before issuing an installation method statement.
What should be confirmed before a sample or bulk order?
Confirm the model code, fiber count, fiber grade, cable OD, construction, jacket classification, route, mechanical limits, drum schedule, marking and required documents. Any sample acceptance criteria should also be written into the order review.
What information produces a more accurate quotation?
Provide the exact count and grade, route/environment, required standards, total quantity, drum lengths, destination, cable marking, required documents and any dimensional or installation constraints.