Outdoor Fiber Cable

GYFTZ 2–216F Stranded Loose Tube LSZH Outdoor Fiber Optic Cable

GYFTZ 2–216F Stranded Loose Tube LSZH Outdoor Fiber Optic Cable for outdoor plant use at 2-30F / 32-60F / 62-72F / 74-96F / 98-120F / 122-144F / 146-216F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

GYFTZ

GYFTZ Cable at a Glance

The proposed BWNFiber GYFTZ page covers a stranded loose-tube cable family listed with an LSZH outer sheath and fiber-count bands from 2 to 216 fibers. The supplied record also lists PBT loose tubes, an FRP central strength member, water-blocking tape and single-mode or multimode fiber options.

Before using these values in a design, purchase order or tender, request the approved specification for the exact fiber count. BWNFiber engineering must confirm the model code, count range, fiber grade, finished-cable dimensions, installation route, mechanical limits, jacket classification and required test documents.

Primary CTA: Request the approved GYFTZ datasheet and configuration review.

Short Answer for Buyers

GYFTZ is presented in the supplied BWNFiber record as a 2–216F stranded loose-tube cable with an LSZH sheath, PBT tube elements, an FRP central strength member and water-blocking tape. Select one fiber-count row and one fiber grade, then confirm the proposed route, cable OD, pulling/crush limits, drum schedule and required evidence before quotation. The current record contains unresolved model and scope conflicts, so no configuration should be released from this draft alone.

Key Configuration Points

  • Fiber-count bands: 2–30F, 32–60F, 62–72F, 74–96F, 98–120F, 122–144F and 146–216F — source-provisional.
  • Fiber options: single-mode or multimode — exact grades and optical matrix require confirmation.
  • Loose-tube/filler material: PBT — source-provisional.
  • Central strength member: FRP, listed as 1.4–2.0 mm ±0.2 mm — source-provisional.
  • Outer sheath: LSZH, listed as 1.6±0.2 mm — confirm that this value is sheath thickness and not finished-cable diameter.
  • Moisture barrier: water-blocking tape — source-provisional.
  • Installation route: TBC — source required. Do not infer aerial, duct, direct-buried, tunnel or indoor suitability from the product name alone.
  • Fire/smoke/halogen classification: TBC — test standard and report required.

Cable Construction

ComponentSource-provisional valueRelease status
Fiber-count family2–216F in count bandsTBC: conflicts with a separate 2–144 cores row
Fiber typeSingle-mode or multimodeTBC: exact grade per order required
Loose-tube and filler materialPBTTBC: confirm finished BOM
Loose-tube/filler diameterΦ1.6–2.2 mm ±0.2 mmTBC: confirm notation and applicable count rows
Central strength memberFRPTBC: confirm whether the entire cable is all-dielectric
Central strength-member diameter1.4–2.0 mm ±0.2 mmTBC: confirm configuration mapping
Outer sheath materialLSZHTBC: compound and test classification required
Outer-sheath value1.6±0.2 mmTBC: confirm that this is sheath thickness
Moisture barrierWater-blocking tapeTBC: confirm full water-blocking construction

Count-Dependent Configuration Matrix

Do not combine values from different rows. The selected count band must remain tied to its diameter, weight, tube/filler count and mechanical limits.

Fiber countNominal cable diameterNominal weightMax. fibers per tubeTubes + fillersTensile, short/long termCrush, short/long termStatus
2–30F7.80±0.5 mm60±5 kg/km651500/600 N1000/300 N per 100 mmTBC — source sign-off
32–60F8.60±0.5 mm65±5 kg/km1251500/600 N1000/300 N per 100 mmTBC — source sign-off
62–72F9.20±0.5 mm100±5 kg/km1261500/600 N1000/300 N per 100 mmTBC — source sign-off
74–96F11.0±0.5 mm130±5 kg/km1281500/600 N1000/300 N per 100 mmTBC — source sign-off
98–120F13.2±0.5 mm160±5 kg/km12101500/600 N1000/300 N per 100 mmTBC — source sign-off
122–144F13.40±0.5 mm204±5 kg/km12121800/600 N1000/300 N per 100 mmTBC — source sign-off
146–216F16.0±0.5 mm205±5 kg/km1218, two layers1800/600 N1000/300 N per 100 mmTBC — source sign-off

Engineering review required: Confirm test methods, duration, units, tolerances and whether all rows belong to the same LSZH product family.

Optical Options

The supplied V4 associates the following attenuation rows with this family. These values must not be published until the original table and its measurement conditions are approved.

Fiber optionWavelengthSource-provisional attenuationRelease status
SM G.652.D1310/1550 nm≤0.34/0.22 dB/kmTBC — confirm grade and conditions
MM 50/125850/1300 nm≤3.0/1.0 dB/kmTBC — confirm grade and conditions
MM 62.5/125850/1300 nm≤3.0/1.0 dB/kmTBC — confirm grade and conditions

The source review also flags unresolved dispersion-slope, PMD and numerical-aperture fields. Do not add standard values from competitor pages or general references.

Mechanical and Environmental Limits

ConditionSource-provisional valueRequired confirmation
Installation temperature−15°C to +60°CTest/source revision and applicable configurations
Operation and transport temperature−40°C to +70°CSeparate storage, transport and operating limits if they differ
Minimum bend radius, long term10 × cable diameterConfirm terminology: installed/no-load condition
Minimum bend radius, short term20 × cable diameterConfirm terminology: installation/under-load condition

These limits do not establish route suitability by themselves. Confirm pulling method, duct or tray dimensions, entry hardware, environmental exposure and local code requirements for the actual project.

How to Select the Correct Configuration

  1. Confirm the model code. Ask BWNFiber to verify that GYFTZ is the correct designation for the requested construction and sheath.
  2. Select one fiber count. Use the corresponding row for cable diameter, weight, tube/filler count and mechanical limits.
  3. Specify one fiber grade. Do not combine single-mode and multimode values in one order line.
  4. Describe the route. State whether the planned route is duct, tray, tunnel, riser, aerial, direct-buried or another environment. BWNFiber must confirm suitability; this page does not.
  5. State fire and material requirements. If LSZH, flame spread, smoke, halogen, UV or another property is mandatory, identify the required standard and classification.
  6. Confirm installation constraints. Include maximum pulling load, bend path, duct/gland size and any handling limits required by the project.
  7. Define the drum schedule. State total quantity, length per drum, acceptable tolerance, marking text and destination.
  8. List required documents. Request the approved datasheet, drawing and applicable test/inspection documents before PO release.

Differences from Related BWNFiber Drafts

Related model/pageSupplied differenceBuyer decisionEvidence gate
GYFTY 2–216F PEPE sheath is listed instead of LSZH; most mechanical rows are otherwise the sameChoose only after route, jacket and product-code requirements are confirmedVerify that these are separate, orderable families and not duplicate records
GYFTY 2–144F all-dielectricDifferent count scope and catalog matrixUse its exact catalog row when that source is the project matchConfirm the all-dielectric claim and model-code relationship
GYFTZY 144FFixed 144F configuration in the local draftUse only if its exact 144F record is approvedIts source file/table identity is already flagged as conflicted
GYTZS 24–144FLocal draft lists corrugated steel tapeUse when the approved armored construction is requiredResolve the local page’s LSZH title versus PE/HDPE table conflict
GYXTZW 2–16FCentral loose tube with two steel wires and a lower count rangeUse for the exact approved central-tube/dual-wire requirementResolve its LSZH title versus PE table conflict

Applications and Compatibility Conditions

Verified application statement available in V4: outdoor fiber access and distribution.

That wording is too broad for final design approval. Before publication and quotation, BWNFiber must define:

  • permitted installation routes;
  • indoor/outdoor transition conditions;
  • UV/weather exposure limits;
  • water-blocking and water-penetration requirements;
  • metallic/non-metallic status of the complete cable;
  • flame/smoke/halogen classification;
  • local code and project-standard compatibility;
  • hardware, duct, gland and closure fit based on finished cable OD.

No compatibility with a brand, connector, enclosure, installation method or standard is claimed in this draft.

Testing and Quality-Control Requirements

No product-specific test method or test-report availability was supplied. For a project RFQ, identify which evidence is required and ask BWNFiber to confirm availability:

Evidence/requestWhy the buyer may need itCurrent status
Approved product datasheet with revisionLocks the ordered configurationTBC — source required
Cable cross-section or construction drawingConfirms layers, materials and dimensionsTBC — source required
Fiber-grade certificate/dataConfirms the ordered optical fiberTBC — source required
Finished-cable attenuation recordConfirms the agreed optical acceptance basisTBC — method/availability required
Tensile/crush/bend test referenceGives context to mechanical limitsTBC — method/availability required
Jacket/fire/smoke/halogen reportSupports any LSZH or flame classificationTBC — standard/classification required
Drum-length and marking inspectionConfirms delivery configurationTBC — inspection process required

Do not imply that all reports are included with every order. Availability, scope, sample size and acceptance criteria must be agreed in the quotation or quality plan.

Packaging and Procurement Information

ItemDraft value/status
Standard drum length2 km — source-provisional; confirm tolerance and availability
Alternative drum lengthTBC — source required
Drum type/dimensionsTBC — source required
Minimum order quantityTBC — source required
Lead timeTBC — source required
Cable markingBuyer should provide required text; format/limits TBC
Export packagingTBC — source required
WarrantyTBC — source required

Information Required for an RFQ

Send the following in one request:

  • product code: GYFTZ, subject to BWNFiber confirmation;
  • exact fiber count;
  • exact fiber grade;
  • proposed installation route and environment;
  • required LSZH/flame/smoke/halogen standard and classification, if applicable;
  • total cable length and quantity;
  • required length per drum and acceptable tolerance;
  • cable marking text;
  • destination country and delivery location;
  • required datasheet, drawing, test report, inspection or tender documents;
  • any duct, gland, closure, pulling-load or bend-path constraints;
  • target delivery date for quotation planning, without assuming a guaranteed lead time.

Primary CTA: Request an approved GYFTZ configuration and quotation.
Secondary CTA: Ask for the current datasheet and construction drawing.

Datasheet, Drawing and Test-Report Area

DocumentStatus/action
Approved GYFTZ datasheetTBC — source required
Approved construction drawingTBC — source required
Count-specific dimensional tableTBC — engineer must sign off the supplied matrix
Optical-fiber dataTBC — confirm selected grade
Mechanical/environmental test referencesTBC — source required
LSZH or flame/smoke/halogen evidenceTBC — source required
FAQ

Frequently Asked Questions

Is GYFTZ the correct model code for this LSZH cable?

The supplied BWNFiber V4 labels the product GYFTZ, but the local product set also contains closely related GYFTY and GYFTZY records. Confirm the model code and approved construction with BWNFiber engineering before using it in a tender or purchase order.

Does this page cover every fiber count from 2 to 216?

The supplied matrix contains seven count bands from 2–30F through 146–216F. A separate construction row says 2–144 cores, so the upper range is not cleared for publication. Request the approved count list for the exact model revision.

Which cable diameter applies to my order?

Use only the row for the selected fiber-count band. Do not use the sheath-thickness value as finished cable OD, and do not combine the diameter or weight from another count band.

Can I order single-mode or multimode fiber?

The supplied record lists both as alternatives. State one exact fiber grade in the RFQ and request the approved optical data for that grade. Do not apply all listed attenuation values to one cable.

Does LSZH prove that this cable meets my fire code?

No. The material label alone does not establish a specific flame, smoke, halogen or building-code classification. State the required standard and classification, then request the applicable evidence for the offered configuration.

Is the cable all-dielectric?

The supplied record lists an FRP central strength member, but a complete bill of materials was not provided. Do not claim all-dielectric construction until BWNFiber confirms that the finished cable contains no metallic elements.

Can this cable be installed in ducts, tunnels, aerial routes or direct burial?

The current record only says outdoor access and distribution. Give BWNFiber the exact route and environment so engineering can confirm suitability. Competitor application claims must not be used as evidence for this product.

What bend limits should the installer use?

The source-provisional record lists 20D short term and 10D long term, where D is cable diameter. Confirm the approved terminology and values for the ordered configuration before issuing an installation method statement.

What should be confirmed before a sample or bulk order?

Confirm the model code, fiber count, fiber grade, cable OD, construction, jacket classification, route, mechanical limits, drum schedule, marking and required documents. Any sample acceptance criteria should also be written into the order review.

What information produces a more accurate quotation?

Provide the exact count and grade, route/environment, required standards, total quantity, drum lengths, destination, cable marking, required documents and any dimensional or installation constraints.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.