Configuration at a Glance

FieldProposed configurationRelease status
ModelGYFTY53Product Owner approval required
Fiber count48FProduct Owner approval required
Fiber gradeG.657.A1 single-modeEngineering approval required
Cable constructionStranded loose tube, double sheath, steel-tape armoredEngineering drawing required
Central strength memberFRPVisible in supplied cross-section; exact variant approval required
ReinforcementKevlar yarnVisible in supplied cross-section; material designation approval required
Inner / outer sheathPE / PEEngineering approval required
Installation routeTBC — source requiredDo not infer from the family name
Applicable standards / certificationsTBC — source requiredDo not claim without the product-level evidence

Cable Construction

The supplied cross-section shows loose tubes arranged around an FRP central member, with jelly, water-blocking yarn and tape, reinforcing yarn, an inner sheath, corrugated steel tape and an outer sheath. The diagram is useful for component identification, but the approved drawing must confirm that every label applies to the orderable 48F G.657.A1 configuration.

Component / parameterDraft valueStatus before publication
Fiber count48FConfirm against controlled source
Fiber gradeG.657.A1Confirm against controlled source
Number of loose tubes4TBC — source required
Number of fillers2TBC — source required
Loose-tube outside diameter2.5 mmTBC — source required
Loose-tube materialPBTTBC — source required
Central strength memberFRPConfirm material and dimensions
ReinforcementKevlar yarnConfirm approved material terminology
Tube filling compoundJellyConfirm material specification
Water-blocking systemWater-blocking yarn and tapeConfirm construction drawing
Inner sheathBlack PEConfirm material/color
Inner-sheath nominal thickness0.9 mmTBC — source required
Inner-sheath diameter9.8 mmTBC — source required
ArmorCorrugated steel tapeConfirm construction drawing
Outer sheathBlack PEConfirm material/color
Outer-sheath nominal thickness2.1 mmTBC — source required
Finished cable diameter15.7 mmTBC — source required, including tolerance
Cable weight208 kg/kmTBC — source required

Cross-section reference for the proposed configuration. Retain the source watermark and verify the exact variant before public use.

Optical Characteristics

The values below were retained from the supplied V4 draft for engineering review. They are not approved public specifications in this delivery.

Parameter / conditionDraft valueStatus
Attenuation at 1310 nm≤0.36 dB/kmTBC — source required
Attenuation at 1550 nm≤0.25 dB/kmTBC — source required
Maximum attenuation difference, 1285–1330 nm≤0.03 dB/kmTBC — source required
Maximum attenuation difference, 1525–1575 nm≤0.02 dB/kmTBC — source required
Zero-dispersion wavelength1300–1324 nmTBC — source required
Zero-dispersion slope≤0.092 ps/(nm²·km)TBC — verify unit and source
Cable cut-off wavelength≤1260 nmTBC — source symbol/condition required
Effective group index at 1310 nm1.466TBC — source required
Effective group index at 1550 nm1.467TBC — source required
Point discontinuity at 1310 nm≤0.05 dBTBC — test condition required
Point discontinuity at 1550 nm≤0.05 dBTBC — test condition required
Cladding diameter124.8 ± 0.7 μmTBC — source required
Cladding non-circularity≤0.7%TBC — source required
Coating diameter245 ± 5 μmTBC — source required
Coating–cladding concentricity error≤12.0 μmTBC — source required
Coating non-circularity≤6.0%TBC — source required
Core–cladding concentricity error≤0.5 μmTBC — source required
Curl radius≥4 mTBC — source required
PMD, maximum individual fiberDraft shows ≤0.2, unit missingBlocked
PMD, link design value (M=20, Q=0.01%)Draft shows ≤0.1, unit missingBlocked
PMD, typical valueDraft shows 0.04, unit missingBlocked
Mode-field diameter at 1310 / 1550 nmSource extraction reportedly labels the result in nmBlocked — likely unit/column issue; do not silently correct

ITU-T G.657 defines fibre-level attributes for G.657.A1. That standard does not validate the finished cable values above; the controlled BWNFiber source and test/inspection documents must do so.

Mechanical and Environmental Draft Values

Parameter / conditionDraft valueStatus
Minimum operating load6000 NTBC — define test/condition
Minimum compressive loading4000 N/100 mmTBC — define test/condition
Bend radius, long term20DBlocked — verify label/value pairing
Bend radius, installation10DBlocked — verify label/value pairing
Impact resistance4.4 J, 3 × 2 impactsTBC — test method required
Torsion10 turns of 180°TBC — test method required
Installation temperature−10°C to +50°CTBC — source required
Operation and transport temperature−40°C to +50°CTBC — separate conditions if applicable
Storage or transportation temperature−50°C to +50°CBlocked — conflicts with the combined range above
Core fluid penetration1 m sample, 1 m water head, 24 hTBC — test method and acceptance criterion required

Interfaces, Termination and Compatibility

No connector, polish, gender, pinning or equipment-brand compatibility is documented for this bulk-cable draft. Specify the termination or splice plan separately. Compatibility must be checked from the fiber grade, cable construction, pathway, approved dimensions, mechanical limits, environmental conditions and termination hardware; it must not be inferred from GYFTY53 alone.

Application Conditions

The supplied draft calls this an outdoor cable, but does not provide a controlled application statement in the delivery folder. Before approving duct, direct-burial, aerial or another installation route, confirm:

  1. The declared installation method for the exact model/configuration.
  2. Pulling tension, crush exposure and bend path.
  3. Duct or trench dimensions, entry points and water-management plan.
  4. Grounding/bonding implications of the steel tape.
  5. Temperature range and handling conditions.
  6. Required local project standards, fire/smoke rating and approval documents.
  7. Compatible glands, clamps, closures, splicing hardware and drum plan.

How to Select and Approve This Configuration

  1. Confirm the network requirement: active fibers, reserve fibers and G.657.A1 requirement.
  2. Define the complete route: indoor/outdoor transitions, duct, trench, aerial sections, pulls and access points.
  3. Check the controlled construction: drawing revision, tube/filler layout, sheath, armor, water blocking and finished diameter.
  4. Verify mechanical and environmental conditions: tensile/crush categories, bend limits, temperature and test methods.
  5. Agree the acceptance package: datasheet, drawing, marking, drum lengths, inspection documents and any required reports.
  6. Freeze the RFQ configuration: model, count, fiber grade, length allocation, quantity, destination and requested documents.

Difference from Related Page Types

  • The Fiber Optic Cable category should help buyers choose a family by route and constraints.
  • A GYFTY53 family page, if approved, should compare counts and approved fiber-grade options.
  • This P008 page should validate only the exact 48F G.657.A1 configuration and its controlled order inputs.
  • A technical guide should explain installation selection, testing or acceptance without acting as a product offer.

If P009 is confirmed to describe the same GYFTY53 family rather than a separate product, merge the family-level content there and keep P008 only when an approved exact-configuration source exists.

Testing, Inspection and Documents

The current package does not prove a specific production test plan or the availability of a public datasheet, drawing or test report. Before ordering, ask BWNFiber to confirm which controlled documents can be supplied for the exact quotation:

  • Approved product datasheet and revision.
  • Cable construction drawing and revision.
  • Fiber and finished-cable specification scope.
  • Marking and drum-length schedule.
  • Applicable inspection/test list and acceptance criteria.
  • Packaging and shipping identification.
  • Any project-specific compliance documents requested in the RFQ.

Do not assume that a generic family certificate or competitor standard applies to this configuration.

Packaging and Procurement Information

FieldBuyer input / status
Total cable lengthBuyer to specify
Length per drumBuyer to specify; feasibility TBC
Quantity / number of drumsBuyer to specify
Cable markingBuyer to provide required text; approval TBC
Delivery destinationBuyer to specify
Export packagingTBC — source required
MOQTBC — source required
Lead timeTBC — quotation required
WarrantyTBC — source required
PriceProject quotation required

RFQ Checklist

Send the following information for a controlled quotation:

  • Product reference: GYFTY53 48F G.657.A1 Double-Sheath Armored Fiber Optic Cable.
  • Installation route and environment.
  • Total cable length and length per drum.
  • Quantity or number of drums.
  • Required cable marking.
  • Destination country, city/port and delivery terms if known.
  • Required datasheet, drawing, inspection/test or compliance documents.
  • Any mandatory mechanical, environmental or project-standard criteria.
  • Termination/splicing plan and associated hardware constraints.

Primary CTA: Request a GYFTY53 48F specification review and project quotation.
Secondary CTA: Ask for the current approved datasheet and construction drawing.

Related Products and Resources


Deterministic Validation Record

CheckResultInterpretation
SEO Growth Framework environment doctor0 errors; 4 optional dependency warningsOffline gates are available; optional Anthropic/MCP/Google libraries are not required for this draft review.
Content graderREVISE — 79.7/100The combined audit + page package is intentionally longer than a product page and remains weak on approved EEAT evidence/schema. This is not a publication pass.
Compliance check after link/disclaimer repair0 hard failures; 0 warningsThe file passes the framework’s text-level compliance rules; this does not close product-fact or publication gates.
Claims registryBlockedprofiles/bwnfiber/data/claims-registry.yaml is absent, so registry-based claim verification could not run.
Live CMS/frontend/GSC verificationNot executedNo CMS authority was granted and no live P008 URL was confirmed.

An approved product datasheet and engineering review are required before release.

FAQ

Frequently Asked Questions

What exact configuration does this page cover?

This draft is limited to the proposed GYFTY53, 48F, G.657.A1, double-sheath, steel-tape-armored configuration. Other counts, fiber grades or constructions require a separate approved configuration.

Is this a general GYFTY53 family page?

No. A family page should cover approved GYFTY53 options across counts and grades. This page is intended for one exact 48F G.657.A1 configuration.

Is the cable approved for direct burial or duct installation?

TBC — source required. Do not infer the route from the model name or competitor pages. Request the current BWNFiber application statement and construction drawing.

What components support and protect the fibers?

The supplied cross-section labels an FRP central member, Kevlar yarn, water-blocking yarn/tape, inner and outer sheaths and corrugated steel tape. Engineering must confirm that the diagram applies to the exact orderable configuration.

What attenuation values apply?

The V4 draft lists ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm. These values remain TBC until checked against the controlled fiber/cable specification and its conditions.

Which bend radius applies during installation?

Not yet confirmed. The current draft pairs 20D with long-term use and 10D with installation, and that pairing requires engineering review before publication or use.

Which temperature range applies?

Not yet confirmed. The draft contains separate ranges that may conflict or refer to different conditions. Engineering must separate installation, operation, storage and transport limits.

Does G.657.A1 define the finished cable bend radius?

No. G.657.A1 is a fiber category. The finished cable bend limit must come from the approved cable specification and installation condition.

Are connectors or equipment compatibility included?

No connector or equipment-brand compatibility is documented in this draft. Define the termination/splicing plan and verify the complete link and hardware separately.

What documents should a buyer request?

Request the approved datasheet, controlled drawing, marking/drum schedule and the applicable inspection/test document list for the quoted configuration.

What information is required for an accurate quotation?

Provide the exact configuration, route, total length, drum-length allocation, quantity, marking, destination and required approval documents. Include any mandatory project criteria.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.