Outdoor Fiber Cable

GYFTY-nB1.3 48F G.652.D Anti-Rodent Loose Tube Fiber Optic Cable

GYFTY-nB1.3 48F G.652.D Anti-Rodent Loose Tube Fiber Optic Cable for outdoor plant use at 48F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

GYFTY-nB1.3

Product Summary

GYFTY-nB1.3 is presented in the supplied BWNFiber record as a 48-fiber outdoor loose-tube cable using G.652.D single-mode fiber, an FRP central strength member, glass yarn around the cable core and an HDPE outer sheath. The listed arrangement is 12 fibers per tube, four loose tubes and two fillers, with a nominal 9.8 mm cable diameter.

This is a configuration-validation page, not a general outdoor-cable guide. Before approval, match the quotation, current datasheet and drawing to the exact model suffix, 48F count, G.652.D grade, tube plan, glass-yarn construction and required installation route.

Buyer short answer: Use this record to prepare an RFQ for the stated 48F configuration. Do not treat the words anti-rodent, outdoor, aerial or duct as route approval. Ask BWNFiber to confirm the controlled construction, test conditions, pulling method, support hardware and acceptance documents for the project.

Request the controlled datasheet and drawing

Configuration at a Glance

Configuration fieldSupplied V4 valueRelease status
ModelGYFTY-nB1.3TBC — controlled model record required
Fiber count48FTBC — controlled datasheet required
Fiber gradeITU-T G.652.DTBC — fiber certificate/datasheet required
Cable constructionStranded loose tubeTBC — drawing required
Fibers per tube12TBC — drawing/table required
Loose tubes / fillers4 / 2TBC — drawing/table required
Loose-tube diameter1.9 mmTBC — tolerance and drawing required
Central strength memberFRP, 2.0 mmTBC — drawing/BOM required
Anti-rodent elementGlass yarnTBC — material and construction record required
Outer sheathHDPE, listed thickness 1.5 mmTBC — nominal/minimum basis required
Nominal cable diameter9.8 mmTBC — tolerance required
Nominal cable weight78 kg/kmTBC — tolerance required
Listed installation routesAerial / ductTBC — route design and support method required

What the Glass-Yarn Construction Does—and Does Not Prove

The supplied cross-section identifies glass yarn outside the stranded cable core. This supports the proposed glass-yarn anti-rodent positioning at the drawing-review level. It does not prove a universal degree of rodent protection, a particular test method, direct-burial suitability, self-supporting aerial performance, UV rating, fire rating or all-dielectric status for every production variant. Those claims require an exact BOM, drawing and applicable test or declaration.

Provisional Mechanical and Environmental Values

The values in this section are transcribed from the supplied V4 record. They are not released specifications because the original controlled source and test basis were not available in the reviewed folder.

ParameterSupplied V4 valueInformation still required
Tensile strength3,000 NShort-term/long-term label, method, loaded length, duration, optical limit and report identity
Crush resistance1,000 N/100 mmMethod, platen geometry, duration, optical/physical acceptance and report identity
Minimum bend radius during installation20 × cable diameterLoaded condition, temperature and source revision
Minimum bend radius after installation10 × cable diameterUnloaded condition, temperature and source revision
Operating temperature-30 °C to +60 °CTest/profile basis and exact label
Installation temperature-30 °C to +60 °CHandling/pulling conditions and exact label
Storage temperature-40 °C to +70 °CConditioning/profile basis and exact label

Mechanical headline values are comparable only when the model, method, specimen, setup, load, duration, optical response and physical acceptance criteria match. For the evidence fields behind tensile, crush and bend values, review BWNFiber’s armored fiber cable mechanical-ratings guide. The guide is a document-review framework; it is not proof that this model passed a test.

Provisional G.652.D Optical Characteristics

The V4 record lists the following optical values. Confirm that the controlled G.652.D fiber certificate and cable datasheet use the same definitions, conditions, units and revision before publication.

Parameter / conditionSupplied V4 valueRelease status
Mode-field diameter at 1310 nm9.2 ± 0.4 µmTBC — source required
Cladding diameter125 ± 1 µmTBC — source required
Core/cladding concentricity error≤0.6 µmTBC — source required
Cladding non-circularity≤1.0%TBC — source required
Cable cut-off wavelength (λcc)≤1260 nmTBC — source required
Fiber cut-off wavelength (λc)1180–1330 nmTBC — source required
Primary coating diameter, excluding color layer245 ± 10 µmTBC — source required
Primary coating diameter, including color layer250 ± 15 µmTBC — source required
Coating/cladding concentricity error≤12.5 µmTBC — source required
Fiber curl radius≥4 mTBC — source required
Attenuation at 1310 nm≤0.36 dB/kmTBC — source required
Attenuation at 1550 nm≤0.21 dB/kmTBC — source required
Chromatic dispersion, 1288–1339 nm≤3.5 ps/(nm·km)TBC — source required
Chromatic dispersion at 1550 nm≤17 ps/(nm·km)TBC — source required
Zero-dispersion wavelength1300–1324 nmTBC — source required
Zero-dispersion slope≤0.092 ps/(nm²·km)TBC — source required
Macrobending loss, Φ 60 mm, 100 turns at 1550 nm≤0.1 dBTBC — test/source required

The V4 line Dispersion mode bias: 0.5 ps/km1/2 is withheld from the publishable table because the metric name and unit are unclear. BWNFiber Engineering must identify the intended parameter and restore the controlled wording if applicable.

ITU-T G.652 defines characteristics of single-mode optical fiber and cable; the fiber designation does not approve the finished cable’s route, mechanical limits or installed-link loss budget. Connector and splice losses must be handled separately in link design and acceptance.

Application and Compatibility Boundaries

Duct Installation

For a duct route, confirm duct size and occupancy, pulling length and method, maximum pulling tension, sidewall pressure where applicable, bend path, water-management plan, lubricant compatibility, handhole access and termination or splice locations. The 3,000 N value cannot be used as an installation limit until its condition and test basis are confirmed.

Supported Aerial Installation

The supplied record lists aerial installation, but it does not establish that this cable is ADSS or self-supporting. Confirm messenger/support method, span, sag, wind and ice conditions, pole hardware, clearances, installation tension and the exact approved cable load data before aerial use.

Rodent-Exposure Review

Glass yarn is shown as the anti-rodent element. Project approval still needs the material definition, coverage/construction, required rodent-resistance method or customer criterion, and any route-specific protective measures. Compare this construction with metallic armor only after electrical/grounding constraints, mechanical exposure, route method and test evidence are defined. See BWNFiber’s outdoor cable rodent and water-damage guide for the selection questions; that guide does not certify this model.

Interfaces and Termination

No connectorized interface is identified in the supplied product record. Treat this as bulk cable unless the quotation defines factory termination. Confirm closure, splice tray, gland, duct, support hardware and termination capacity against the 48F count and final cable diameter.

How to Select and Approve This Configuration

  1. Lock the route. Mark each duct, supported aerial, building-entry and termination segment. Do not approve a single construction for every segment by default.
  2. Freeze the optical requirement. Confirm G.652.D, wavelengths, distance, equipment interfaces, capacity, reserve fibers and the project loss budget.
  3. Match one controlled model. Require the quotation, datasheet and drawing to identify GYFTY-nB1.3, 48F, the same suffix and revision.
  4. Verify the construction. Check the 4-tube/2-filler plan, 12 fibers per tube, FRP central member, glass-yarn layer, HDPE sheath, outside diameter and tolerances.
  5. Verify route limits. Compare the documented pulling, crush, bend and temperature conditions with the installation design. A larger headline value is not automatically a better match.
  6. Define acceptance evidence. State required fiber certificate, dimensional inspection, drum test, test methods, report fields, marking, packaging and deviation-control process.
  7. Release the order only after document approval. Keep the approved datasheet, drawing, quotation, deviation log and purchase specification on the same revision.

How This Product Differs From Adjacent Cable Families

Adjacent familyMain distinction to verifyDo not assume
Standard metallic loose-tube cableMetallic central member and/or laminate may change electrical, grounding and mechanical considerationsThat a broad standard loose-tube page describes this FRP/glass-yarn configuration
ADSS cableSelf-supporting design is selected against span, sag, wind, ice and hardware requirementsThat the word aerial makes GYFTY-nB1.3 an ADSS cable
Steel-tape armored/direct-burial cableMetallic armor can address a different mechanical/rodent requirement and may introduce bonding/grounding considerationsThat glass yarn and steel tape provide identical protection or route approval
General GYFTY family pageFamily pages support discovery and configuration comparisonThat one family table proves this exact 48F model and revision

Use the fiber optic cable selection page for route-level family selection. Use this product page only for the exact 48F configuration after its controlled evidence is approved.

Testing and Quality-Control Documents to Request

This review did not receive model-specific test reports. The following list is a procurement request, not a claim that the documents or results already exist:

  • Controlled product datasheet and construction drawing with revision/date.
  • Fiber certificate identifying G.652.D and the supplied optical values.
  • Dimensional inspection record for cable diameter, sheath and relevant construction fields.
  • Model-specific tensile, crush, bend and temperature records where required by the purchase specification.
  • Drum-level optical test record stating measured fibers, wavelengths, length and acceptance criteria.
  • Rodent-resistance evidence or customer-specific construction declaration where required.
  • Material, fire, UV, regulatory or destination documents only when required and available for this exact model.
  • Written deviation or substitution approval before production.

Packaging and Procurement Information

Procurement fieldStatus
Standard drum lengthTBC — source required
Drum type and dimensionsTBC — source required
Net/gross weight per drumTBC — source required
Cable marking formatTBC — buyer text and source required
End sealing and weather protectionTBC — source required
MOQTBC — commercial confirmation required
Production lead timeTBC — quotation-specific
WarrantyTBC — commercial terms required
Export documentsTBC — destination/order-specific

Information Required for an RFQ

Send BWNFiber:

  • Product reference: GYFTY-nB1.3, 48F, G.652.D.
  • Route segments and installation method for each segment.
  • Total cable length and required length per drum.
  • Duct size/occupancy and pulling plan, or aerial support/span/environmental inputs.
  • Required tensile, crush, bend and temperature criteria with method/edition where specified.
  • Rodent-exposure requirement and acceptance evidence.
  • Closure, gland, splice tray and termination interfaces.
  • Required datasheet, drawing, fiber certificate and test-report fields.
  • Cable marking, packaging, inspection and destination requirements.
  • Quantity, destination, Incoterm and requested delivery window.

Send the route and RFQ requirements to BWNFiber

Datasheet, Drawing and Test-Report Area

  • Controlled datasheet: TBC — source required
  • Construction drawing: TBC — source required
  • G.652.D fiber certificate: TBC — source required
  • Model-specific test record(s): TBC — scope and availability required

Do not expose an empty or broken download button. Add a download only after the file, revision, model scope and public-use permission are confirmed.

FAQ

Frequently Asked Questions

What exact configuration does this page cover?

It covers the proposed GYFTY-nB1.3 configuration with 48 G.652.D fibers arranged as 12 fibers per tube in four loose tubes, plus two fillers. These fields remain provisional until they are tied to the current controlled datasheet and drawing.

How is rodent protection provided?

The supplied V4 record and cross-section identify glass yarn around the cable core. The material, coverage and applicable rodent-resistance criterion still need controlled product evidence. Do not interpret the anti-rodent label as a guarantee against all rodent damage.

Is this cable metallic-armored?

The supplied construction lists FRP, glass yarn and an HDPE sheath; it does not list steel or aluminum armor. Confirm the full BOM before calling the finished cable all-dielectric or non-metallic, and do not describe glass yarn and metallic tape armor as equivalent.

Can this cable be installed in a duct?

The V4 record lists duct installation. Project approval still requires the duct route, pulling plan, bend path, cable limits, accessories and test/document requirements to match the exact model.

Can this cable be used for aerial installation?

Only after the support method and route loads are approved. The word aerial does not show that the cable is self-supporting or that it meets a particular ADSS span requirement.

What bend limits are listed?

The V4 record lists 20 times the cable diameter during installation and 10 times the cable diameter after installation. The controlled source must confirm the loaded/unloaded conditions, temperature and exact model scope before release.

Are the attenuation values an installed-link loss budget?

No. The listed values are provisional cabled-fiber attenuation limits at 1310 nm and 1550 nm. A link budget must separately include cable length, splices, connectors, passive components, operating wavelength, engineering margin and acceptance method.

What should a buyer request before approving the cable?

Request a revision-controlled datasheet and drawing, fiber certificate, route-specific mechanical evidence, dimensional and drum-test records, marking/packaging details and a written response to every project requirement or deviation.

What information should be included in the quotation request?

State the exact model reference, 48F G.652.D configuration, route and installation method, length per drum, mechanical/environmental criteria, rodent requirement, interfaces, required documents, marking, packaging, quantity and destination.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.