Product Value Summary
This page identifies one specific outdoor cable configuration: GYFTC8S, 96 fibers, a PE sheath, an FRP central strength member, corrugated steel tape, and a galvanized-steel messenger made from 7 × 1.2 mm wires. It is intended for review as a figure-8 self-supporting aerial cable configuration. The integrated messenger and the optical cable body must be evaluated together with the span, sag, clamps, wind and ice loads, clearances, and local installation rules.
Before quotation or technical approval: request the controlled datasheet and confirm the exact fiber grade, cable dimensions, mechanical limits, temperature range, optical limits, test methods, and permitted span. Those values are not established by the evidence available for this offline draft.
Primary CTA: Request the GYFTC8S 96F controlled datasheet and configuration review.
Quick Configuration Answer
| Buyer question | Current answer |
|---|---|
| Which model and count does this page cover? | GYFTC8S, 96F only. |
| What construction is documented? | Stranded loose-tube cable body; FRP central strength member; corrugated steel tape; PE outer sheath; integral galvanized-steel messenger. |
| What messenger is listed? | 7 × 1.2 mm galvanized steel wire. |
| Which installation family is intended? | Figure-8 self-supporting aerial installation; project suitability remains subject to route and load review. |
| Which fiber grade is supplied? | TBC — source required. |
| What span, tensile and crush limits apply? | TBC — controlled model-specific data required. |
| Is the product approved for direct burial, duct, indoor, power-line or fire-rated use? | Not established by the supplied evidence. Do not infer these uses from “outdoor,” “PE,” “armored,” or “self-supporting.” |
Key Features — Documented Configuration
- Fiber count: 96F.
- Cable family: GYFTC8S figure-8 self-supporting outdoor fiber optic cable.
- Cable core: Eight PBT loose tubes are listed in the supplied draft.
- Central strength member: FRP.
- Armor / moisture-barrier layer: Corrugated steel tape is listed; the exact material designation and test evidence require confirmation.
- Messenger: Galvanized steel wire, 7 × 1.2 mm.
- Outer sheath: PE.
These points identify the proposed construction. They do not by themselves establish span capacity, tensile performance, crush resistance, water-blocking performance, UV performance, temperature limits, fire classification, optical performance, or standards compliance.
Technical Specifications
| Component / parameter | Proposed GYFTC8S 96F configuration | Evidence status |
|---|---|---|
| Model | GYFTC8S | Supported by supplied V4 draft |
| Fiber count | 96F | Supported by supplied V4 draft |
| Cable structure | Figure-8 self-supporting, stranded loose tube | Supported by supplied V4 draft and supplied construction image |
| Loose-tube count | 8 | Supported by supplied V4 draft and visible construction image |
| Loose-tube material | PBT | Supported by supplied V4 draft |
| Loose-tube diameter | 2.0 mm | Internal draft value; controlled source required before release |
| Central strength member | FRP | Supported by supplied V4 draft and visible construction image |
| Messenger | Galvanized steel wire, 7 × 1.2 mm | Supported by supplied V4 draft and visible construction image |
| Armor / barrier | Corrugated steel tape | Supported by supplied V4 draft and visible construction image |
| Outer sheath | PE | Supported by supplied V4 draft and visible construction image |
| Fiber grade | TBC — source required | Not established |
| Cable outside dimensions | TBC — controlled drawing required | The supplied image shows 12.0 mm and 6.0 mm callouts, but their tolerances and exact dimensional meaning are not controlled in this package |
| Cable weight | TBC — source required | Not established |
| Attenuation and test wavelengths | TBC — source required | Not established |
| Minimum bend radius | TBC — source required | Not established |
| Tensile and crush limits | TBC — source required | Not established |
| Installation / operating / storage temperature | TBC — source required | Not established |
| Permitted span and sag/load case | TBC — route calculation and model data required | Project-specific |
| Standards compliance / certification | TBC — controlled evidence required | Not established |
Interfaces and End Condition
This is a bulk outdoor cable page, not a connectorized patch-cord page. No connector, polish, polarity, pinning, or equipment-interface option is established in the supplied material.
| Field | Required decision |
|---|---|
| Supplied end condition | TBC — bare cable / prepared end / other |
| Closure or termination interface | Confirm cable-entry diameter, sealing range, gland, routing space and splice capacity |
| Aerial hardware | Confirm clamp type, messenger interface, attachment method, sag and tension design |
| Electrical environment | Confirm clearances, bonding/grounding requirements for metallic components, and route-owner approval |
Fiber Type and Configuration
The fiber grade and optical specification are not recoverable from the supplied evidence. do not use for order release G.652.D, G.657.A1/A2, G.655, single-mode, multimode, attenuation, macrobend, or wavelength claims until the controlled 96F specification confirms them.
The following fields must be locked before order release:
- Fiber standard and grade.
- Fiber manufacturer or approved equivalent policy, if relevant.
- Attenuation limits and test wavelengths.
- Proof-test and geometric requirements, if required by the project.
- Tube and fiber color code.
- Required factory and delivery test records.
Application and Compatibility Conditions
Intended application family
The documented figure-8 construction is intended for a self-supporting aerial route in which the integral steel messenger carries the designed installation load. Suitability must be confirmed for the exact route; the model name alone does not approve a span.
Do not approve until these interfaces are checked
| Interface | Buyer must confirm |
|---|---|
| Pole route | Longest and ruling spans, route angles, attachment heights, clearances and local rules |
| Environmental load | Wind, ice, temperature, exposure, corrosion conditions and safety factors |
| Support hardware | Suspension/dead-end clamp compatibility with the listed messenger and approved load case |
| Cable handling | Reel setup, pulling method, bend control, pulling tension and installation temperature |
| Closures and cabinets | Cable-entry diameter, sealing range, grounding/bonding treatment, splice tray capacity and reserve storage |
| Optical system | Fiber grade, wavelength, distance, loss budget, splice plan and acceptance limits |
This page does not establish suitability for duct, direct burial, indoor pathways, plenum/riser spaces, subscriber drop service, or installation near power infrastructure.
How to Select and Approve This Configuration
- Confirm the page identity. Use GYFTC8S 96F only; do not mix values from another fiber count or GYFTC8S supplier table.
- Map the aerial route. Provide span lengths, route angles, attachment points, clearances, wind/ice assumptions and environmental exposure.
- Lock the optical requirement. State the fiber grade, wavelengths, link distance, loss budget and acceptance limits.
- Review the installed system. Approve the cable, messenger, clamps, sag/tension design, closures and grounding/bonding method together.
- Request controlled documents. Obtain the current datasheet, cross-section drawing, dimensional tolerances and applicable test records.
- Release the order only after document approval. The purchase description, drawing revision and acceptance criteria must refer to the same configuration.
Difference From Related Cable Families
| Cable family | Primary distinction | Routing rule |
|---|---|---|
| GYFTC8S 96F on this page | 96F stranded loose-tube figure-8 construction with a listed steel messenger and corrugated steel tape | Exact-model technical validation and RFQ |
| ADSS cable | All-dielectric self-supporting aerial construction without a metallic messenger | Use the ADSS category for span/load/electrical-environment selection, not this SKU page |
| FTTH figure-8 drop cable | Lower-count last-mile/drop construction; not interchangeable with a 96F distribution cable | Use the FTTH drop category for subscriber routes |
| Armored/direct-burial cable | Armor is a construction feature; burial is an installation approval | Do not treat corrugated steel tape as automatic direct-burial approval |
| Connectorized outdoor assembly | Finished optical interfaces and connector-specific test requirements | Use fiber-cable-assembly or patch-cord pages when connectors are required |
Testing and Quality-Control Requirements
No BWNFiber test process or result is established by the supplied evidence. For a project release, request a document set that identifies the exact GYFTC8S 96F configuration and includes, as applicable:
- Optical attenuation limits, wavelengths, method and acceptance criteria.
- Cable dimensions, construction drawing and tolerances.
- Tensile, crush, bend and temperature limits with test conditions.
- Messenger and clamp/load assumptions for the intended aerial route.
- Water-blocking, sheath, armor and environmental evidence required by the project.
- Inspection or test record identity, revision, date and lot/reel traceability.
Do not use a competitor datasheet to fill these BWNFiber product fields.
Packaging and Procurement Information
| Procurement field | Required input / status |
|---|---|
| Product identity | GYFTC8S 96F figure-8 self-supporting PE outdoor fiber optic cable |
| Fiber grade | TBC — buyer requirement and controlled confirmation |
| Total quantity | Buyer to provide |
| Length per drum | Buyer to provide; feasibility TBC |
| Number of drums | Buyer to provide or calculate after approved drum length |
| Cable marking | Buyer to provide |
| Drum/packaging requirement | TBC — source required |
| Delivery destination and Incoterm | Buyer to provide |
| Required documents | Datasheet, drawing, test/inspection records and other project-specific documents |
| MOQ, price, lead time, warranty and stock | TBC — quotation required |
Required Information for an RFQ
Send the following in one request:
- Model and count: GYFTC8S, 96F.
- Route: pole layout, span schedule, route angles, attachment heights and installation method.
- Environment: wind, ice, temperature, corrosion exposure, clearances and applicable local rules.
- Optical requirement: fiber grade, wavelengths, distance, loss budget and acceptance limits.
- Mechanical requirement: permitted tension, crush, bend and approved support hardware or design criteria.
- Order quantity: total length, length per drum and number of drums.
- Identification: cable marking, reel labels and traceability fields.
- Documents: controlled datasheet, drawing, test records, compliance evidence and destination documents.
- Delivery: destination, Incoterm and requested schedule.
RFQ CTA
Request the GYFTC8S 96F controlled datasheet and configuration review. Include the route and load inputs above so BWNFiber can check whether the proposed cable and hardware can be evaluated for the project. Document availability, price and schedule remain subject to quotation and technical confirmation.
Datasheet, Drawing and Test-Report Area
| Document | Current status | Release rule |
|---|---|---|
| Controlled GYFTC8S 96F datasheet | TBC — source required | Product/Engineering owner approval |
| Controlled cross-section drawing | TBC — source required | Drawing number and revision required |
| Optical test limits / record | TBC — source required | Wavelength, method, acceptance and traceability required |
| Mechanical/environmental evidence | TBC — source required | Exact model and conditions required |
| Standards/certification evidence | TBC — source required | do not use for order release a standard or certification without the document |
Frequently Asked Questions
What exact configuration does this page cover?
It covers the proposed BWNFiber GYFTC8S 96F figure-8 self-supporting outdoor cable with a PE sheath, FRP central strength member, corrugated steel tape and a 7 × 1.2 mm galvanized-steel messenger. Other fiber counts or constructions require separate model-level confirmation.
Is GYFTC8S the same as ADSS cable?
No. This GYFTC8S configuration includes a metallic messenger as part of the figure-8 construction. ADSS is all-dielectric and supports its own load without a metallic messenger. Select between them from the electrical environment, route loads, span design, hardware and maintenance requirements.
Is the maximum span available?
Not from the evidence supplied for this draft. Maximum span cannot be approved from the model name or messenger size alone. Provide the route and load case, then request the exact cable data and sag/tension review.
Which fiber type is used in this 96F cable?
TBC — source required. Confirm the fiber grade and its optical limits on the controlled 96F datasheet before quotation or publication.
Does the corrugated steel tape make the cable suitable for direct burial?
No such approval is established here. Armor describes part of the construction; direct burial is an installation use that requires model-specific sheath, water-blocking, mechanical, environmental and project evidence.
Which clamp should be used with the messenger?
The clamp must match the messenger construction, permitted load, span design and attachment method. Submit the proposed hardware and route calculation for approval; this draft does not nominate a compatible clamp.
Are optical attenuation limits available?
No controlled wavelength-specific limits are available in this package. Request the exact values, test method and acceptance criteria for the selected fiber grade.
What dimensions should be used for closure or gland selection?
Use only the controlled drawing. The supplied image contains 12.0 mm and 6.0 mm callouts, but their tolerances and exact dimensional definitions are not established by this package.
What documents should a buyer request before order release?
Request the controlled datasheet, cross-section drawing, configuration-specific optical and mechanical limits, applicable test records, cable-marking approval and any project-required compliance evidence.
What information should be included in the quotation request?
State GYFTC8S 96F, the required fiber grade, route and span schedule, environmental/load inputs, hardware assumptions, total length, length per drum, quantity, marking, required documents, delivery destination and requested schedule.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.