Armored / Direct Burial Cable

GYFTA53 2-144F Stranded Loose Tube Non-Metallic Armored Fiber Optic Cable

GYFTA53 2-144F Stranded Loose Tube Non-Metallic Armored Fiber Optic Cable with documented armored construction at 2-144F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

GYFTA53

Product summary

The BWNFiber GYFTA53 family is recorded as a 2–144F stranded loose-tube cable with an FRP central member, APL layer, PE inner sheath, corrugated steel/PSP armor and PE outer sheath. The supplied record also labels the product “non-metallic” or “all-dielectric”; because steel/PSP armor is listed, confirm whether “non-metallic” describes only the central member before ordering or publication.

The family record lists G.652, G.655, 50/125 μm and 62.5/125 μm fiber alternatives, PE sheathing, 1000/3000 N tensile values, 1000/3000 N per 100 mm crush values, 12.5D/25D bend-radius values and a -40°C to +70°C series temperature range. These are source-record values, not a substitute for the approved configuration datasheet.

Quick answer for buyers

Choose a GYFTA53 count group first, then confirm the Xn fiber suffix, fiber type, jacket/armor construction, route, and final datasheet. Do not combine optical values from different fiber rows. If the project requires a genuinely all-dielectric cable, stop and request the correct variant: the supplied construction includes APL and steel/PSP armor.

Construction and terminology

Layer/fieldSupplied recordPublication boundary
Optical fibersG.652 / G.655 / 50/125 μm / 62.5/125 μm alternativesExact type-to-suffix mapping TBC
Loose tubesGel-filled loose tubes around an FRP central memberConfirm fill compound and water-blocking evidence
Central memberFRP“Non-metallic central member” is supportable; “all-dielectric cable” is not while APL/PSP remains
Moisture/inner layerAPL; PE inner sheathConfirm layer sequence and water-blocking test
ArmorCorrugated steel/PSP listed in the V4 recordConfirm metallic armor, grounding/bonding and exact armor description
Outer sheathPEConfirm grade, UV and route suitability

Terminology note: “Non-metallic strength member” and “all-dielectric cable” are not interchangeable. The former can describe an FRP central member; the latter normally excludes conductive armor. Engineering must choose the approved product identity.

Configuration table

Catalog modelFiber countLoose tubesFillersReference weight (kg/km)Tensile long/short (N)Crush long/short (N/100 mm)Bend radius
GYFTA53-2~6Xn2–6172281000/30001000/300012.5D/25D
GYFTA53-8~12Xn8–12262281000/30001000/300012.5D/25D
GYFTA53-14~18Xn14–1835TBC — source review notes 82 kg/km; engineering confirmation required1000/30001000/300012.5D/25D
GYFTA53-20~24Xn20–24442281000/30001000/300012.5D/25D
GYFTA53-26~30Xn26–30532281000/30001000/300012.5D/25D
GYFTA53-32~36Xn32–36622281000/30001000/300012.5D/25D
GYFTA53-38~42Xn38–42712281000/30001000/300012.5D/25D
GYFTA53-44~48Xn44–48802281000/30001000/300012.5D/25D
GYFTA53-50~60Xn50–60932401000/30001000/300012.5D/25D
GYFTA53-62~72Xn62–721022401000/30001000/300012.5D/25D
GYFTA53-74~84Xn74–841112401000/30001000/300012.5D/25D
GYFTA53-86~96Xn86–961202401000/30001000/300012.5D/25D
GYFTA53-98~108Xn98–1081312761000/30001000/300012.5D/25D
GYFTA53-110~120Xn110–1201402761000/30001000/300012.5D/25D
GYFTA53-122~132Xn122–1321513261000/30001000/300012.5D/25D
GYFTA53-134~144Xn134–1441603261000/30001000/300012.5D/25D

Xn is retained as printed in the supplied catalog model. Its fiber-type meaning and color-code mapping require the approved catalog/datasheet.

Optical alternatives

Fiber type1310 nm1550 nm850 nm1300 nmBandwidthCutoff / NA
G.652≤0.36 dB/km≤0.22 dB/km———λcc ≤1260 nm
G.655≤0.40 dB/km≤0.23 dB/km———λcc ≤1450 nm
50/125 μm——≤3.3 dB/km≤1.2 dB/km≥500 MHz·km @850 and @1300NA 0.200±0.015
62.5/125 μm——≤3.5 dB/km≤1.2 dB/km≥200 @850; ≥500 @1300NA 0.275±0.015

These are alternative fiber rows from the supplied record. They must not be merged into one configuration. Confirm the selected fiber type, suffix, wavelength acceptance limits and test report on the order datasheet.

Route fit and selection

  1. Select the count group. Match the required live fibers and spares to the catalog range; do not infer a 144F design from a 2–6F row.
  2. Confirm Xn and fiber type. State G.652, G.655, 50/125 μm or 62.5/125 μm explicitly; request the suffix mapping if the catalog does not show it.
  3. Confirm the layer stack. Ask whether the approved build includes APL, PE inner sheath, corrugated steel/PSP armor and PE outer sheath, and whether “non-metallic” refers only to FRP.
  4. Check mechanical limits. Use the count-group row’s weight, tensile, crush and bend-radius values. Confirm whether 12.5D/25D is static/dynamic or another manufacturer convention.
  5. Qualify the route. Confirm duct/direct burial/aerial/indoor transition, water exposure, UV, temperature, grounding/bonding and local code requirements. The current record alone does not prove every route.

Do not select this page as an all-dielectric solution until the armor conflict is resolved. Do not claim IEC/YD/T compliance, rodent resistance, or direct-burial approval without a product-specific document.

Related-product boundary

Buyer needPage role
Exact GYFTA53 count, fiber option and RFQThis product page
Broad armored/direct-burial cable selectionBWNFiber category page (URL to confirm)
Mechanical test-evidence comparisonArmored Fiber Cable Mechanical Ratings
Fiber-count and route selectionFiber Optic Cable Selection for FTTx Projects
2–12F central loose-tube armored alternative2–12F Central Loose Tube Outdoor Armored Cable

These links are recommendations only; verify target URL ownership and avoid using this SKU page to compete with broad category or guide intent.

Testing, documentation and RFQ

Request the controlled datasheet/drawing and, if required by the project, the applicable test report. Ask the supplier to identify the test method, specimen configuration, load, duration and acceptance criterion for tensile, crush, bending, water-blocking and optical attenuation. The existence of a test request is not evidence that the product has passed it.

Include in the RFQ:

  • catalog model and count group;
  • Xn suffix and fiber type;
  • final armor/sheath terminology and route;
  • total length, reel/drum length and quantity;
  • marking text, delivery destination and packaging;
  • requested optical/mechanical test documents;
  • any grounding, UV, water-blocking, fire or local approval requirement.

Packaging and procurement information

The supplied record does not confirm standard reel length, drum dimensions, net/gross drum weight, marking format, MOQ, stock, lead time, warranty or delivery terms. Keep these fields as TBC — source required until sales/operations provides the approved order sheet. At minimum, the quotation should state total cable length, length per reel/drum, quantity, marking text and destination.

Datasheet, drawing and test-report area

Provide links only after the files are approved and tied to the selected configuration:

  • Configuration datasheet: TBC — source required
  • Construction drawing: TBC — source required
  • Optical test/attenuation report: TBC — source required
  • Tensile/crush/bend or water-blocking test report: TBC — source required

Do not use a generic family PDF as evidence for every count group unless the document explicitly covers the selected model and fiber type.

CTA

Request a configuration review and quotation. Send the count group, fiber type/suffix, route, total length, reel length, delivery destination, marking and required evidence. Ask BWNFiber to confirm the armor terminology and return the approved datasheet before production.

Recommended internal links

Armored fiber cable mechanical ratings · Fiber optic cable selection for FTTx projects · 2–12F central loose-tube outdoor armored cable · FTTH drop cable category

Disclaimer: Figures are transcribed from the supplied BWNFiber record and are for review/reference only, not a guarantee for every configuration. The approved order datasheet and engineering confirmation govern.

FAQ

FAQ

What does GYFTA53 2–144F mean?
It identifies a GYFTA53 family offered in the supplied record across count groups from 2 to 144 fibers. The correct catalog row, loose-tube/filler count and weight must be selected for the requested configuration.

Is this cable all-dielectric?
Not established. The record says “non-metallic” and lists an FRP central member, but it also lists APL and corrugated steel/PSP armor. Confirm whether the approved product is metallic-armored or a different all-dielectric variant.

Which fiber types are available?
The record lists G.652, G.655, 50/125 μm and 62.5/125 μm as alternatives. The Xn suffix mapping and final optical limits require the approved datasheet.

Can I use the 2–6F weight for a 14–18F cable?
No. Use the exact count-group row. The 14–18F reference weight is currently TBC; engineering must confirm the source note of 82 kg/km or provide a replacement value.

Is it suitable for direct burial or outdoor use?
The supplied record lists PE sheathing and a -40°C to +70°C series range, but that alone does not prove UV, water-blocking, direct-burial or route approval. Confirm the installation method and environmental evidence before ordering.

What does 12.5D/25D mean?
It is the supplied bend-radius notation, where D is cable diameter. Confirm which value is static and which is dynamic, and follow the approved installation datasheet.

What documents should accompany an RFQ?
Request the configuration datasheet, construction drawing, fiber/suffix mapping, reel/marking details and any project-required optical, tensile, crush, bend or water-blocking test evidence.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.