FTTH Drop Cable

GJYXFCH 2F FRP Steel-Messenger LSZH FTTH Drop Fiber Optic Cable

GJYXFCH 2F FRP Steel-Messenger LSZH FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

GJYXFCH

Configuration at a Glance

AttributeP146 offline recordRelease status
Model familyGJYXFCHTBC — product owner confirmation
Fiber count2FTBC — controlled source required
Fiber gradeTBCBlocked — must not be inferred
Strength membersFRP, 0.5 mmTBC — drawing/source row required
Separate messengerSteel wire, 1.0 mmTBC — drawing/source row required
Sheath material / colorLSZH / blackTBC — rating and controlled source required
Cable profile1.95 ± 0.05 × 5.2 ± 0.1 mmTBC — drawing/source row required
Reference weight13 kg/kmTBC — basis/tolerance required
End conditionTBCBuyer and product owner must define

Cable Construction

The offline construction record shows two fibers centered between two FRP strength members, with a separate steel-wire messenger joined to the main cable body by the sheath. This arrangement is not interchangeable with an all-dielectric FRP-messenger cable, a non-messenger bow-type cable or another GJYXFCH family entry.

Before approval, match the controlled cross-section drawing to the intended clamp, entry port, bend path and termination method. The existing watermarked diagram is a construction reference only; it is not a dimensional drawing, certification, or test record.

Technical Specifications

The following values are retained from the supplied P146 offline record so that Engineering can verify them. They are not publication-cleared specifications. Remove any row that cannot be tied to the controlled datasheet, drawing, test method and revision.

Optical Characteristics

ParameterOffline valuePublication gate
Attenuation at 1310 nm≤ 0.4 dB/kmTBC — confirm fiber grade and source
Attenuation at 1550 nm≤ 0.3 dB/kmTBC — confirm fiber grade and source
Attenuation difference, 1285–1330 nm≤ 0.03 dB/kmTBC — source/test basis required
Attenuation difference, 1525–1575 nm≤ 0.02 dB/kmTBC — source/test basis required
Zero-dispersion wavelength1312 ± 10 nmTBC — confirm applicability
Zero-dispersion slope≤ 0.090 ps/(nm²·km)TBC — confirm notation and source
Cable cut-off wavelength≤ 1260 nmTBC — confirm symbol and source
Group index at 1310 / 1550 nm1.466 / 1.467TBC — source required
Point discontinuity at 1310 / 1550 nm≤ 0.05 dB / ≤ 0.05 dBTBC — method and source required

Withheld from public copy: PMD rows with missing units and MFD rows recorded with nm are quarantined until Engineering confirms the correct units, values and source. No silent unit conversion is allowed.

Mechanical and Environmental Limits

ParameterOffline valuePublication gate
Installation temperature−20 to +60 °CTBC — confirm test/handling definition
Operation and transport temperature−20 to +70 °CTBC — separate operation/transport/storage if applicable
Minimum bend radius, long term10DTBC — confirm D and service condition
Minimum bend radius, short term20DTBC — confirm installation condition
Tensile load, long term300 NTBC — test method/source required
Tensile load, short term600 NTBC — test method/source required
Crush load2000 N/100 mmTBC — duration/method/source required

Application and Selection Conditions

This page does not yet establish an approved span length, installation environment, fire classification, UV resistance, water-blocking performance, direct-burial suitability, rodent resistance or compliance certificate. LSZH identifies the recorded sheath material; it does not by itself prove compliance with a building code or fire classification.

Before selecting the cable, confirm:

  1. The full route: aerial, façade, duct, building entry and indoor sections.
  2. Required fiber grade and compatibility with the installed optical network.
  3. Span, sag, wind exposure, attachment hardware and messenger/clamp compatibility where an aerial section is proposed.
  4. Cable profile, bend path and entry-port dimensions.
  5. Project-specific tensile, crush, temperature, fire/smoke and environmental requirements.
  6. Unterminated or terminated end condition and the planned splice/termination workflow.

If the project requires an all-dielectric route, a different fiber count, another sheath/rating or a different messenger, request a separately documented configuration rather than treating it as an option on this SKU.

How This Configuration Differs from Related Drop Cables

Related configurationKey differenceBuyer action
1F GJYXFCH with FRP messengerDifferent fiber count and messenger materialUse the separate 1F record; do not copy its values.
GJYXFCH 2F G.657.A2 Figure-8 draft (P157)Different dimensions/specification set in the supplied draftProduct owner must decide whether it is a distinct SKU or a duplicate to merge.
Broad GJYXFCH/GJYXFCJH/GJYXFCDH family draft (P163)Multiple models, counts and fiber alternativesKeep family selection on the category/family page; do not use family options as P146 facts.
Non-messenger butterfly/drop cableNo separate messenger roleSelect by route and support hardware, not by model-name similarity.

Documents and Acceptance Requirements

Request the following controlled documents for the quoted configuration:

  • Product datasheet with model/configuration and revision.
  • Dimensioned cross-section drawing.
  • Declared fiber grade and optical limits.
  • Mechanical/environmental test method and limits.
  • Sheath material plus any project-required fire/smoke rating evidence.
  • Drum/roll length, tolerance, marking and packaging specification.
  • Inspection or test record offered for the order, with the measurement scope stated.

Document availability, test scope and report format are TBC — BWNFiber must confirm them before they are promised.

Information to Include in Your RFQ

Send the information below to reduce configuration mismatch and quotation follow-up:

  • Product reference: GJYXFCH 2F, P146.
  • Route and installation method, including any aerial section and approximate span.
  • Required fiber grade.
  • Required cable profile and construction: FRP strength members + steel-wire messenger.
  • Sheath material and any required fire/smoke/environmental rating.
  • Total length, length per drum or roll, and quantity.
  • Cable marking text and language.
  • End condition and termination/splicing plan.
  • Delivery destination and required trade/packing documents.
  • Datasheet, drawing, sample or test-record requirements.

Primary CTA: Request P146 specification confirmation and a quotation.
Secondary CTA: Ask BWNFiber to review the route and required documents before the configuration is released.

Request Specification Confirmation and a Quotation

Send BWNFiber the route, required fiber grade, length schedule, quantity and approval documents. BWNFiber should first confirm the controlled P146 specification and then quote the matched configuration. If the route requires a different messenger, rating, fiber grade or fiber count, treat it as a different configuration.

CTA button: Request P146 Specification & Quote

FAQ

Frequently Asked Questions

Which fiber count does this page cover?

This page is scoped to the 2F P146 configuration. A 1F, 4F or family-level option must use its own controlled specification and should not inherit the values on this page.

What is the difference between the FRP members and the steel messenger?

The supplied offline record identifies two FRP strength members in the main cable body and a separate steel-wire messenger. Engineering must confirm the drawing and dimensions before this construction description is released.

Is the fiber G.657.A1 or G.657.A2?

TBC — source required. The P146 draft does not identify the fiber grade, so a grade must not be inferred from a nearby GJYXFCH product.

Is this cable approved for indoor and outdoor installation?

TBC — source required. An LSZH material label and a messenger do not by themselves establish every indoor, outdoor, aerial or building-code use. Confirm the route, rating and controlled datasheet.

What span can this cable support?

No approved span is available in the supplied P146 evidence. Span selection requires the declared mechanical limits plus the route, sag, wind, clamps and attachment conditions.

What bend limits apply?

The offline record lists 10D long term and 20D short term. Engineering must confirm what D refers to and which value applies during installation versus service before publication.

Are the attenuation values a complete FTTH link budget?

No. The offline values are expressed per kilometre for the cable/fiber record. A complete link budget also accounts for connectors, splices, splitters and design margin, none of which is specified by this product page.

Does LSZH mean the cable meets a specific flame standard?

No specific fire or smoke standard is proven by the supplied file. Request the exact rating and supporting document required by the project.

What should be verified before a sample or bulk order?

Verify model, fiber grade/count, construction, dimensions, sheath/rating, mechanical/environmental limits, length/marking, end condition and required documents against the same controlled revision.

What should I include in the quotation request?

Include the route, fiber grade, configuration, total and per-drum length, quantity, marking, end condition, delivery destination and requested datasheet/drawing/test records.

Related Products