GJYXFCH
GJYXFCH 2F FRP Steel-Messenger LSZH FTTH Drop Fiber Optic Cable
GJYXFCH 2F FRP Steel-Messenger LSZH FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Configuration at a Glance
| Attribute | P146 offline record | Release status |
|---|---|---|
| Model family | GJYXFCH | TBC — product owner confirmation |
| Fiber count | 2F | TBC — controlled source required |
| Fiber grade | TBC | Blocked — must not be inferred |
| Strength members | FRP, 0.5 mm | TBC — drawing/source row required |
| Separate messenger | Steel wire, 1.0 mm | TBC — drawing/source row required |
| Sheath material / color | LSZH / black | TBC — rating and controlled source required |
| Cable profile | 1.95 ± 0.05 × 5.2 ± 0.1 mm | TBC — drawing/source row required |
| Reference weight | 13 kg/km | TBC — basis/tolerance required |
| End condition | TBC | Buyer and product owner must define |
Cable Construction
The offline construction record shows two fibers centered between two FRP strength members, with a separate steel-wire messenger joined to the main cable body by the sheath. This arrangement is not interchangeable with an all-dielectric FRP-messenger cable, a non-messenger bow-type cable or another GJYXFCH family entry.
Before approval, match the controlled cross-section drawing to the intended clamp, entry port, bend path and termination method. The existing watermarked diagram is a construction reference only; it is not a dimensional drawing, certification, or test record.
Technical Specifications
The following values are retained from the supplied P146 offline record so that Engineering can verify them. They are not publication-cleared specifications. Remove any row that cannot be tied to the controlled datasheet, drawing, test method and revision.
Optical Characteristics
| Parameter | Offline value | Publication gate |
|---|---|---|
| Attenuation at 1310 nm | ≤ 0.4 dB/km | TBC — confirm fiber grade and source |
| Attenuation at 1550 nm | ≤ 0.3 dB/km | TBC — confirm fiber grade and source |
| Attenuation difference, 1285–1330 nm | ≤ 0.03 dB/km | TBC — source/test basis required |
| Attenuation difference, 1525–1575 nm | ≤ 0.02 dB/km | TBC — source/test basis required |
| Zero-dispersion wavelength | 1312 ± 10 nm | TBC — confirm applicability |
| Zero-dispersion slope | ≤ 0.090 ps/(nm²·km) | TBC — confirm notation and source |
| Cable cut-off wavelength | ≤ 1260 nm | TBC — confirm symbol and source |
| Group index at 1310 / 1550 nm | 1.466 / 1.467 | TBC — source required |
| Point discontinuity at 1310 / 1550 nm | ≤ 0.05 dB / ≤ 0.05 dB | TBC — method and source required |
Withheld from public copy: PMD rows with missing units and MFD rows recorded with nm are quarantined until Engineering confirms the correct units, values and source. No silent unit conversion is allowed.
Mechanical and Environmental Limits
| Parameter | Offline value | Publication gate |
|---|---|---|
| Installation temperature | −20 to +60 °C | TBC — confirm test/handling definition |
| Operation and transport temperature | −20 to +70 °C | TBC — separate operation/transport/storage if applicable |
| Minimum bend radius, long term | 10D | TBC — confirm D and service condition |
| Minimum bend radius, short term | 20D | TBC — confirm installation condition |
| Tensile load, long term | 300 N | TBC — test method/source required |
| Tensile load, short term | 600 N | TBC — test method/source required |
| Crush load | 2000 N/100 mm | TBC — duration/method/source required |
Application and Selection Conditions
This page does not yet establish an approved span length, installation environment, fire classification, UV resistance, water-blocking performance, direct-burial suitability, rodent resistance or compliance certificate. LSZH identifies the recorded sheath material; it does not by itself prove compliance with a building code or fire classification.
Before selecting the cable, confirm:
- The full route: aerial, façade, duct, building entry and indoor sections.
- Required fiber grade and compatibility with the installed optical network.
- Span, sag, wind exposure, attachment hardware and messenger/clamp compatibility where an aerial section is proposed.
- Cable profile, bend path and entry-port dimensions.
- Project-specific tensile, crush, temperature, fire/smoke and environmental requirements.
- Unterminated or terminated end condition and the planned splice/termination workflow.
If the project requires an all-dielectric route, a different fiber count, another sheath/rating or a different messenger, request a separately documented configuration rather than treating it as an option on this SKU.
How This Configuration Differs from Related Drop Cables
| Related configuration | Key difference | Buyer action |
|---|---|---|
| 1F GJYXFCH with FRP messenger | Different fiber count and messenger material | Use the separate 1F record; do not copy its values. |
| GJYXFCH 2F G.657.A2 Figure-8 draft (P157) | Different dimensions/specification set in the supplied draft | Product owner must decide whether it is a distinct SKU or a duplicate to merge. |
| Broad GJYXFCH/GJYXFCJH/GJYXFCDH family draft (P163) | Multiple models, counts and fiber alternatives | Keep family selection on the category/family page; do not use family options as P146 facts. |
| Non-messenger butterfly/drop cable | No separate messenger role | Select by route and support hardware, not by model-name similarity. |
Documents and Acceptance Requirements
Request the following controlled documents for the quoted configuration:
- Product datasheet with model/configuration and revision.
- Dimensioned cross-section drawing.
- Declared fiber grade and optical limits.
- Mechanical/environmental test method and limits.
- Sheath material plus any project-required fire/smoke rating evidence.
- Drum/roll length, tolerance, marking and packaging specification.
- Inspection or test record offered for the order, with the measurement scope stated.
Document availability, test scope and report format are TBC — BWNFiber must confirm them before they are promised.
Information to Include in Your RFQ
Send the information below to reduce configuration mismatch and quotation follow-up:
- Product reference: GJYXFCH 2F, P146.
- Route and installation method, including any aerial section and approximate span.
- Required fiber grade.
- Required cable profile and construction: FRP strength members + steel-wire messenger.
- Sheath material and any required fire/smoke/environmental rating.
- Total length, length per drum or roll, and quantity.
- Cable marking text and language.
- End condition and termination/splicing plan.
- Delivery destination and required trade/packing documents.
- Datasheet, drawing, sample or test-record requirements.
Primary CTA: Request P146 specification confirmation and a quotation.
Secondary CTA: Ask BWNFiber to review the route and required documents before the configuration is released.
Request Specification Confirmation and a Quotation
Send BWNFiber the route, required fiber grade, length schedule, quantity and approval documents. BWNFiber should first confirm the controlled P146 specification and then quote the matched configuration. If the route requires a different messenger, rating, fiber grade or fiber count, treat it as a different configuration.
CTA button: Request P146 Specification & Quote
Frequently Asked Questions
Which fiber count does this page cover?
This page is scoped to the 2F P146 configuration. A 1F, 4F or family-level option must use its own controlled specification and should not inherit the values on this page.
What is the difference between the FRP members and the steel messenger?
The supplied offline record identifies two FRP strength members in the main cable body and a separate steel-wire messenger. Engineering must confirm the drawing and dimensions before this construction description is released.
Is the fiber G.657.A1 or G.657.A2?
TBC — source required. The P146 draft does not identify the fiber grade, so a grade must not be inferred from a nearby GJYXFCH product.
Is this cable approved for indoor and outdoor installation?
TBC — source required. An LSZH material label and a messenger do not by themselves establish every indoor, outdoor, aerial or building-code use. Confirm the route, rating and controlled datasheet.
What span can this cable support?
No approved span is available in the supplied P146 evidence. Span selection requires the declared mechanical limits plus the route, sag, wind, clamps and attachment conditions.
What bend limits apply?
The offline record lists 10D long term and 20D short term. Engineering must confirm what D refers to and which value applies during installation versus service before publication.
Are the attenuation values a complete FTTH link budget?
No. The offline values are expressed per kilometre for the cable/fiber record. A complete link budget also accounts for connectors, splices, splitters and design margin, none of which is specified by this product page.
Does LSZH mean the cable meets a specific flame standard?
No specific fire or smoke standard is proven by the supplied file. Request the exact rating and supporting document required by the project.
What should be verified before a sample or bulk order?
Verify model, fiber grade/count, construction, dimensions, sheath/rating, mechanical/environmental limits, length/marking, end condition and required documents against the same controlled revision.
What should I include in the quotation request?
Include the route, fiber grade, configuration, total and per-drum length, quantity, marking, end condition, delivery destination and requested datasheet/drawing/test records.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.