GJYXFCH
GJYXFCH 1F 1.0mm Steel-Messenger 0.5mm FRP FTTH Drop Fiber Optic Cable
GJYXFCH 1F 1.0mm Steel-Messenger 0.5mm FRP FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Product Value Summary
This GJYXFCH configuration combines one G.657.A1 single-mode fiber, one 1.0 mm phosphated-steel messenger and two 0.5 mm FRP strength members in a black LSZH sheath. Its recorded cable profile is 2.0 ± 0.1 × 5.0 ± 0.1 mm, with an approximate mass of 15.5 kg/km.
Use this page to identify the exact construction and prepare an RFQ. Do not approve an aerial route from the model name alone: span, sag, wind and ice exposure, attachment hardware, installation load, local code requirements and the final technical datasheet still need project review.
Primary CTA: Request the P158 datasheet and configuration review
Secondary CTA: Send an RFQ checklist
Short Answer for Buyers
P158 is the candidate BWNFiber page for a 1-fiber GJYXFCH drop cable with a steel support messenger and FRP cable-strength members. Specify all three elements—1F G.657.A1 fiber, the 1.0 mm steel messenger, and the two 0.5 mm FRP members—because the GJYXFCH family also includes materially different messenger, fiber-grade and dimensional variants. Before order release, confirm the corrected tensile ratings, route approval, jacket rating, reel length, marking and required inspection documents.
Configuration Snapshot
| Decision field | P158 recorded configuration | Buyer action |
|---|---|---|
| Fiber count | 1F | Confirm one working fiber is correct for the service plan |
| Fiber type | G.657.A1 | Match the approved network and bend requirements |
| Support messenger | 1 × 1.0 mm phosphated steel wire | Confirm metallic messenger is permitted and the aerial design is reviewed |
| Cable strength members | 2 × 0.5 mm FRP | Do not substitute a steel-member or all-FRP variant without approval |
| Sheath | Black LSZH | Confirm the project-specific fire, smoke, UV and outdoor rating; LSZH alone proves none of these |
| Cable profile | 2.0 ± 0.1 × 5.0 ± 0.1 mm | Check clamps, entries, seals and installation tools |
| Approximate cable mass | 15.5 kg/km | Confirm against the released datasheet |
| End condition | TBC — source required | State unterminated or pre-terminated requirements in the RFQ |
| Standard reel length | TBC — source required | State required length per drum or roll |
| Aerial span/load class | TBC — engineering review required | Provide span, sag, wind/ice and hardware inputs |
Cable Construction
| Component or parameter | Recorded specification | Evidence status |
|---|---|---|
| Fiber count | 1F | Internal V4 source mapping; F0644 referenced but unavailable in this review |
| Fiber type | G.657.A1 | Internal V4 source mapping |
| Fiber color | TBC — source required | Not established in the supplied page file |
| Support messenger | Phosphated steel wire, 1 piece, 1.0 mm | Internal V4 source mapping |
| Cable strength members | FRP, 2 pieces, 0.5 mm | Internal V4 source mapping |
| Outer-sheath material and color | Black LSZH | Internal V4 source mapping |
| Cable dimensions | 2.0 ± 0.1 × 5.0 ± 0.1 mm | Internal V4 source mapping |
| Approximate cable mass | 15.5 kg/km | Internal V4 source mapping |
| Cable marking | TBC — source required | Confirm text, interval, color and tolerance |
The support messenger and the two cable-strength members perform different structural roles. Do not shorten the configuration to “FRP cable” or “steel cable”: either phrase can hide the material combination that distinguishes P158 from other GJYXFCH variants.
Optical Characteristics
| Parameter | Recorded limit | Release note |
|---|---|---|
| Attenuation at 1310 nm | ≤ 0.36 dB/km | Confirm against the released P158 datasheet and agreed test method |
| Attenuation at 1550 nm | ≤ 0.22 dB/km | Confirm against the released P158 datasheet and agreed test method |
| Cable cut-off wavelength | ≤ 1260 nm | Confirm against the released P158 datasheet |
These are recorded finished-cable fiber characteristics, not a complete installed-link budget. The project link budget must separately include connector, splice, splitter and engineering margins where applicable.
Mechanical and Environmental Performance
| Parameter | Recorded value | Release status |
|---|---|---|
| Minimum bend radius — source label “Operation” | 30D | TBC: engineering must map the source label to the approved dynamic/installation or service condition |
| Minimum bend radius — source label “Using” | 15D | TBC: engineering must map the source label to the approved static/service or installation condition |
| Crush resistance — long term | 1000 N/100 mm | Confirm source-table alignment and test method |
| Crush resistance — short term | 2200 N/100 mm | Confirm source-table alignment and test method |
| Storage temperature | −40°C to +70°C | Confirm against released datasheet |
| Operating temperature | −30°C to +60°C | Confirm against released datasheet |
| Tensile strength — long term | TBC — conflicting source row shows 600 N | Blocked: the recorded long-term value exceeds the recorded short-term value |
| Tensile strength — short term | TBC — conflicting source row shows 300 N | Blocked: engineering must correct and approve the pair before publication |
| Installation temperature | TBC — source required | Do not substitute storage or operating temperature |
D must be defined in the released datasheet before the bend-radius values are used for installation. The fiber grade does not replace the finished-cable bend limits.
Compatibility and Application Conditions
This page is for FTTH subscriber-drop procurement where the approved construction calls for a one-fiber GJYXFCH profile with a metallic support messenger and twin FRP cable-strength members.
Confirm the following before selecting P158:
- The route is an approved subscriber-drop application, not a feeder, direct-burial or ADSS route.
- A metallic messenger is permitted near the planned infrastructure and electrical environment.
- Span, sag, wind, ice, pole/building attachments and clamps have been reviewed against an approved load class.
- The 2.0 × 5.0 mm profile fits every clamp, entry, seal and termination point.
- The project accepts G.657.A1 and the recorded optical limits.
- The black LSZH sheath has the exact fire, smoke, halogen, UV and environmental documentation required by the project.
- Indoor/outdoor transitions and local code requirements are documented.
- The final end condition, length, marking and packing are included in the purchase description.
Not established by the current evidence
- A maximum aerial span or sag table
- UV-resistance or outdoor-weathering compliance
- A fire classification or North American listing
- Water blocking, armor, rodent resistance or direct-burial suitability
- Connector type, polish, insertion loss or return loss
- Specific IEC, YD/T, UL, CPR, RoHS or other product compliance
- MOQ, price, stock, lead time, warranty or production capacity
- Batch test method, sampling plan or acceptance limits beyond the recorded parameters
Each item above remains TBC — source required.
How to Select the Correct GJYXFCH Configuration
- Fix the fiber requirement. Confirm 1F and G.657.A1 against the approved network design.
- Choose the support system. P158 uses a steel messenger. If the route requires an all-dielectric construction, use a separately documented variant.
- Keep the messenger and side members distinct. Specify one 1.0 mm steel messenger plus two 0.5 mm FRP members.
- Check the complete profile. Match the 2.0 × 5.0 mm dimensions to clamps, seals, wall entries and tools.
- Approve the route conditions. State span, sag, wind/ice, attachment hardware, indoor/outdoor transitions and local requirements.
- Close the technical exceptions. Do not release the order until the corrected tensile pair and bend-condition labels are signed off.
- Close the commercial details. Add length per reel, quantity, marking, packing, destination and document requirements.
Differences from Related GJYXFCH Variants
| Variant decision | P158 | Do not confuse it with |
|---|---|---|
| Messenger material | 1.0 mm phosphated steel wire | A 1.0 mm FRP/GFRP messenger variant |
| Cable strength members | 2 × 0.5 mm FRP | A configuration using steel side members or 0.4 mm FRP members |
| Fiber count | 1F | A 2F or multi-fiber family configuration |
| Fiber grade | G.657.A1 in the supplied P158 record | A G.657.A2 product page |
| Recorded profile | 2.0 ± 0.1 × 5.0 ± 0.1 mm | A similar-looking 1.95 × 5.2 mm or 2.0 × 5.2 mm variant |
The shared GJYXFCH family name does not make these configurations interchangeable. Use a customer-facing part number or approved configuration code to prevent the wrong source row, image or test record from being attached to an order.
Related Selection Resources
- Compare the broader FTTH drop cable model range before choosing an exact construction.
- Review drop cable strength-member roles when comparing steel, FRP and aramid elements.
- Use the FTTH drop cable selection and installation guide to document route conditions.
- Compare longer-span aerial FTTH options when P158 has no approved span data for the route.
- Review the complete FTTx route so the drop cable matches the distribution and premises interfaces.
Testing and Quality-Control Requirements
The supplied evidence does not establish a BWNFiber test procedure or a batch-report commitment. For the quotation and technical approval, state which documents and checks are required:
| Approval item | What to request | Current status |
|---|---|---|
| Product identity | Released P158 datasheet with revision and configuration code | TBC |
| Construction | Cross-section drawing identifying fiber, messenger, strength members and dimensions | TBC |
| Optical performance | Agreed wavelengths, limits, method, sampling and result format | TBC |
| Mechanical performance | Corrected tensile pair, crush limits, bend conditions and referenced methods | TBC |
| Environment | Installation, operation and storage ranges with test references | TBC |
| Material/rating | LSZH composition and every project-required fire, smoke, UV or environmental document | TBC |
| Traceability | Reel/lot ID, marking, length record and document-to-lot linkage | TBC |
| Packing | Reel type, standard/approved length, end sealing and shipping protection | TBC |
Packaging and Procurement Information
Packaging details are not established in the supplied page file. Record them in the quotation instead of transferring a reel length or packing specification from another GJYXFCH supplier or BWNFiber variant.
Information required for an RFQ
- Product reference: P158 / GJYXFCH 1F steel-messenger + FRP configuration
- Approved fiber grade and fiber count
- Route: indoor, outdoor wall, aerial, duct transition or other
- Aerial inputs where applicable: span, sag, wind/ice, attachment and clamp details
- Total length and required length per drum or roll
- Quantity
- Cable marking text, interval, color and language
- End condition: unterminated or required termination details
- Required datasheet, drawing, test report, material declaration and inspection records
- Packing, labeling and destination requirements
- Requested sample and approval process
- Commercial fields: target delivery date, MOQ and quotation validity — all TBC until quoted
Datasheet, Drawing and Test-Report Area
| Download or record | Status |
|---|---|
| P158 technical datasheet | TBC — source required |
| P158 cross-section drawing | TBC — source required |
| Corrected tensile and bend-condition approval | TBC — engineering approval required |
| Batch optical/mechanical test report | TBC — define requirement in RFQ |
| Material, fire/smoke and environmental declarations | TBC — project-specific |
Frequently Asked Questions
What exact configuration does P158 cover?
P158 covers one G.657.A1 fiber, one 1.0 mm phosphated-steel messenger, two 0.5 mm FRP cable-strength members and a black LSZH sheath in a recorded 2.0 ± 0.1 × 5.0 ± 0.1 mm profile. Engineering must still release the source table and customer-facing SKU.
Is the messenger steel or FRP?
The P158 record identifies a 1.0 mm phosphated-steel messenger. The two 0.5 mm elements beside the fiber are FRP cable-strength members. An FRP-messenger GJYXFCH cable is a different configuration.
Is this an all-dielectric drop cable?
No. The recorded construction contains a steel messenger. If the route restricts metallic elements, request a separately documented all-dielectric configuration.
Can this cable be approved for any aerial span?
No. The current evidence does not state a maximum span or a load/sag table. Provide the span, wind/ice exposure, sag, attachment hardware and clamp details for engineering review.
What do the two bend values mean?
The source labels are recorded as “Operation: 30D” and “Using: 15D.” Those labels are ambiguous. BWNFiber engineering must map them to the approved installation/dynamic and service/static conditions and define D before publication or field use.
Why are tensile values not shown as approved specifications?
The source row recorded 600 N long term and 300 N short term. Because that order is internally suspect and conflicts with common short-term/long-term relationships, both values are withheld pending source-table and engineering confirmation.
Does LSZH mean the cable meets a specific fire code or outdoor rating?
No. LSZH identifies a material characteristic; it does not by itself prove a particular flame test, smoke limit, listing, UV rating or local-code approval. Request the exact project-required evidence.
Are the attenuation values a complete FTTH link budget?
No. The recorded limits—≤0.36 dB/km at 1310 nm and ≤0.22 dB/km at 1550 nm—apply to the cable-fiber record. A link budget also accounts for connectors, splices, splitters and design margin.
What is the standard reel length?
The supplied page file does not establish a standard reel length. State the required length per drum or roll in the RFQ and confirm the approved packing specification.
Which documents should be requested before a bulk order?
Request a revision-controlled datasheet, cross-section drawing, corrected mechanical table, applicable material/rating documents, agreed test and inspection records, marking approval, reel/lot traceability and packing details.
What should I send for a quotation?
Send the exact P158 construction, route and aerial inputs, total length, length per reel, quantity, marking, end condition, destination, required sample and approval documents. State any project standard or test requirement instead of assuming it from the family name.