FTTH Drop Cable

GJYXFCH 1F 1.0mm Steel-Messenger 0.5mm FRP FTTH Drop Fiber Optic Cable

GJYXFCH 1F 1.0mm Steel-Messenger 0.5mm FRP FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

GJYXFCH

Product Value Summary

This GJYXFCH configuration combines one G.657.A1 single-mode fiber, one 1.0 mm phosphated-steel messenger and two 0.5 mm FRP strength members in a black LSZH sheath. Its recorded cable profile is 2.0 ± 0.1 × 5.0 ± 0.1 mm, with an approximate mass of 15.5 kg/km.

Use this page to identify the exact construction and prepare an RFQ. Do not approve an aerial route from the model name alone: span, sag, wind and ice exposure, attachment hardware, installation load, local code requirements and the final technical datasheet still need project review.

Primary CTA: Request the P158 datasheet and configuration review
Secondary CTA: Send an RFQ checklist

Short Answer for Buyers

P158 is the candidate BWNFiber page for a 1-fiber GJYXFCH drop cable with a steel support messenger and FRP cable-strength members. Specify all three elements—1F G.657.A1 fiber, the 1.0 mm steel messenger, and the two 0.5 mm FRP members—because the GJYXFCH family also includes materially different messenger, fiber-grade and dimensional variants. Before order release, confirm the corrected tensile ratings, route approval, jacket rating, reel length, marking and required inspection documents.

Configuration Snapshot

Decision fieldP158 recorded configurationBuyer action
Fiber count1FConfirm one working fiber is correct for the service plan
Fiber typeG.657.A1Match the approved network and bend requirements
Support messenger1 × 1.0 mm phosphated steel wireConfirm metallic messenger is permitted and the aerial design is reviewed
Cable strength members2 × 0.5 mm FRPDo not substitute a steel-member or all-FRP variant without approval
SheathBlack LSZHConfirm the project-specific fire, smoke, UV and outdoor rating; LSZH alone proves none of these
Cable profile2.0 ± 0.1 × 5.0 ± 0.1 mmCheck clamps, entries, seals and installation tools
Approximate cable mass15.5 kg/kmConfirm against the released datasheet
End conditionTBC — source requiredState unterminated or pre-terminated requirements in the RFQ
Standard reel lengthTBC — source requiredState required length per drum or roll
Aerial span/load classTBC — engineering review requiredProvide span, sag, wind/ice and hardware inputs

Cable Construction

Component or parameterRecorded specificationEvidence status
Fiber count1FInternal V4 source mapping; F0644 referenced but unavailable in this review
Fiber typeG.657.A1Internal V4 source mapping
Fiber colorTBC — source requiredNot established in the supplied page file
Support messengerPhosphated steel wire, 1 piece, 1.0 mmInternal V4 source mapping
Cable strength membersFRP, 2 pieces, 0.5 mmInternal V4 source mapping
Outer-sheath material and colorBlack LSZHInternal V4 source mapping
Cable dimensions2.0 ± 0.1 × 5.0 ± 0.1 mmInternal V4 source mapping
Approximate cable mass15.5 kg/kmInternal V4 source mapping
Cable markingTBC — source requiredConfirm text, interval, color and tolerance

The support messenger and the two cable-strength members perform different structural roles. Do not shorten the configuration to “FRP cable” or “steel cable”: either phrase can hide the material combination that distinguishes P158 from other GJYXFCH variants.

Optical Characteristics

ParameterRecorded limitRelease note
Attenuation at 1310 nm≤ 0.36 dB/kmConfirm against the released P158 datasheet and agreed test method
Attenuation at 1550 nm≤ 0.22 dB/kmConfirm against the released P158 datasheet and agreed test method
Cable cut-off wavelength≤ 1260 nmConfirm against the released P158 datasheet

These are recorded finished-cable fiber characteristics, not a complete installed-link budget. The project link budget must separately include connector, splice, splitter and engineering margins where applicable.

Mechanical and Environmental Performance

ParameterRecorded valueRelease status
Minimum bend radius — source label “Operation”30DTBC: engineering must map the source label to the approved dynamic/installation or service condition
Minimum bend radius — source label “Using”15DTBC: engineering must map the source label to the approved static/service or installation condition
Crush resistance — long term1000 N/100 mmConfirm source-table alignment and test method
Crush resistance — short term2200 N/100 mmConfirm source-table alignment and test method
Storage temperature−40°C to +70°CConfirm against released datasheet
Operating temperature−30°C to +60°CConfirm against released datasheet
Tensile strength — long termTBC — conflicting source row shows 600 NBlocked: the recorded long-term value exceeds the recorded short-term value
Tensile strength — short termTBC — conflicting source row shows 300 NBlocked: engineering must correct and approve the pair before publication
Installation temperatureTBC — source requiredDo not substitute storage or operating temperature

D must be defined in the released datasheet before the bend-radius values are used for installation. The fiber grade does not replace the finished-cable bend limits.

Compatibility and Application Conditions

This page is for FTTH subscriber-drop procurement where the approved construction calls for a one-fiber GJYXFCH profile with a metallic support messenger and twin FRP cable-strength members.

Confirm the following before selecting P158:

  1. The route is an approved subscriber-drop application, not a feeder, direct-burial or ADSS route.
  2. A metallic messenger is permitted near the planned infrastructure and electrical environment.
  3. Span, sag, wind, ice, pole/building attachments and clamps have been reviewed against an approved load class.
  4. The 2.0 × 5.0 mm profile fits every clamp, entry, seal and termination point.
  5. The project accepts G.657.A1 and the recorded optical limits.
  6. The black LSZH sheath has the exact fire, smoke, halogen, UV and environmental documentation required by the project.
  7. Indoor/outdoor transitions and local code requirements are documented.
  8. The final end condition, length, marking and packing are included in the purchase description.

Not established by the current evidence

  • A maximum aerial span or sag table
  • UV-resistance or outdoor-weathering compliance
  • A fire classification or North American listing
  • Water blocking, armor, rodent resistance or direct-burial suitability
  • Connector type, polish, insertion loss or return loss
  • Specific IEC, YD/T, UL, CPR, RoHS or other product compliance
  • MOQ, price, stock, lead time, warranty or production capacity
  • Batch test method, sampling plan or acceptance limits beyond the recorded parameters

Each item above remains TBC — source required.

How to Select the Correct GJYXFCH Configuration

  1. Fix the fiber requirement. Confirm 1F and G.657.A1 against the approved network design.
  2. Choose the support system. P158 uses a steel messenger. If the route requires an all-dielectric construction, use a separately documented variant.
  3. Keep the messenger and side members distinct. Specify one 1.0 mm steel messenger plus two 0.5 mm FRP members.
  4. Check the complete profile. Match the 2.0 × 5.0 mm dimensions to clamps, seals, wall entries and tools.
  5. Approve the route conditions. State span, sag, wind/ice, attachment hardware, indoor/outdoor transitions and local requirements.
  6. Close the technical exceptions. Do not release the order until the corrected tensile pair and bend-condition labels are signed off.
  7. Close the commercial details. Add length per reel, quantity, marking, packing, destination and document requirements.

Differences from Related GJYXFCH Variants

Variant decisionP158Do not confuse it with
Messenger material1.0 mm phosphated steel wireA 1.0 mm FRP/GFRP messenger variant
Cable strength members2 × 0.5 mm FRPA configuration using steel side members or 0.4 mm FRP members
Fiber count1FA 2F or multi-fiber family configuration
Fiber gradeG.657.A1 in the supplied P158 recordA G.657.A2 product page
Recorded profile2.0 ± 0.1 × 5.0 ± 0.1 mmA similar-looking 1.95 × 5.2 mm or 2.0 × 5.2 mm variant

The shared GJYXFCH family name does not make these configurations interchangeable. Use a customer-facing part number or approved configuration code to prevent the wrong source row, image or test record from being attached to an order.

Related Selection Resources

Testing and Quality-Control Requirements

The supplied evidence does not establish a BWNFiber test procedure or a batch-report commitment. For the quotation and technical approval, state which documents and checks are required:

Approval itemWhat to requestCurrent status
Product identityReleased P158 datasheet with revision and configuration codeTBC
ConstructionCross-section drawing identifying fiber, messenger, strength members and dimensionsTBC
Optical performanceAgreed wavelengths, limits, method, sampling and result formatTBC
Mechanical performanceCorrected tensile pair, crush limits, bend conditions and referenced methodsTBC
EnvironmentInstallation, operation and storage ranges with test referencesTBC
Material/ratingLSZH composition and every project-required fire, smoke, UV or environmental documentTBC
TraceabilityReel/lot ID, marking, length record and document-to-lot linkageTBC
PackingReel type, standard/approved length, end sealing and shipping protectionTBC

Packaging and Procurement Information

Packaging details are not established in the supplied page file. Record them in the quotation instead of transferring a reel length or packing specification from another GJYXFCH supplier or BWNFiber variant.

Information required for an RFQ

  • Product reference: P158 / GJYXFCH 1F steel-messenger + FRP configuration
  • Approved fiber grade and fiber count
  • Route: indoor, outdoor wall, aerial, duct transition or other
  • Aerial inputs where applicable: span, sag, wind/ice, attachment and clamp details
  • Total length and required length per drum or roll
  • Quantity
  • Cable marking text, interval, color and language
  • End condition: unterminated or required termination details
  • Required datasheet, drawing, test report, material declaration and inspection records
  • Packing, labeling and destination requirements
  • Requested sample and approval process
  • Commercial fields: target delivery date, MOQ and quotation validity — all TBC until quoted

Datasheet, Drawing and Test-Report Area

Download or recordStatus
P158 technical datasheetTBC — source required
P158 cross-section drawingTBC — source required
Corrected tensile and bend-condition approvalTBC — engineering approval required
Batch optical/mechanical test reportTBC — define requirement in RFQ
Material, fire/smoke and environmental declarationsTBC — project-specific
FAQ

Frequently Asked Questions

What exact configuration does P158 cover?

P158 covers one G.657.A1 fiber, one 1.0 mm phosphated-steel messenger, two 0.5 mm FRP cable-strength members and a black LSZH sheath in a recorded 2.0 ± 0.1 × 5.0 ± 0.1 mm profile. Engineering must still release the source table and customer-facing SKU.

Is the messenger steel or FRP?

The P158 record identifies a 1.0 mm phosphated-steel messenger. The two 0.5 mm elements beside the fiber are FRP cable-strength members. An FRP-messenger GJYXFCH cable is a different configuration.

Is this an all-dielectric drop cable?

No. The recorded construction contains a steel messenger. If the route restricts metallic elements, request a separately documented all-dielectric configuration.

Can this cable be approved for any aerial span?

No. The current evidence does not state a maximum span or a load/sag table. Provide the span, wind/ice exposure, sag, attachment hardware and clamp details for engineering review.

What do the two bend values mean?

The source labels are recorded as “Operation: 30D” and “Using: 15D.” Those labels are ambiguous. BWNFiber engineering must map them to the approved installation/dynamic and service/static conditions and define D before publication or field use.

Why are tensile values not shown as approved specifications?

The source row recorded 600 N long term and 300 N short term. Because that order is internally suspect and conflicts with common short-term/long-term relationships, both values are withheld pending source-table and engineering confirmation.

Does LSZH mean the cable meets a specific fire code or outdoor rating?

No. LSZH identifies a material characteristic; it does not by itself prove a particular flame test, smoke limit, listing, UV rating or local-code approval. Request the exact project-required evidence.

Are the attenuation values a complete FTTH link budget?

No. The recorded limits—≤0.36 dB/km at 1310 nm and ≤0.22 dB/km at 1550 nm—apply to the cable-fiber record. A link budget also accounts for connectors, splices, splitters and design margin.

What is the standard reel length?

The supplied page file does not establish a standard reel length. State the required length per drum or roll in the RFQ and confirm the approved packing specification.

Which documents should be requested before a bulk order?

Request a revision-controlled datasheet, cross-section drawing, corrected mechanical table, applicable material/rating documents, agreed test and inspection records, marking approval, reel/lot traceability and packing details.

What should I send for a quotation?

Send the exact P158 construction, route and aerial inputs, total length, length per reel, quantity, marking, end condition, destination, required sample and approval documents. State any project standard or test requirement instead of assuming it from the family name.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.