FTTH Drop Cable

GJYXFCH-1B6a1 LSZH Outdoor FTTH Drop Fiber Optic Cable

GJYXFCH-1B6a1 LSZH Outdoor FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

GJYXFCH-1B6a1

Product Summary

The GJYXFCH-1B6a1 is a self-supporting drop-cable configuration under review for FTTH subscriber connections. The supplied product record identifies G.657.A1 single-mode fiber, a black LSZH sheath, a nominal 2.0 × 5.0 mm cable profile, two side strength members, and a 1.0 mm phosphated-steel messenger. The record does not yet establish the fiber count unambiguously, and its drawing and table conflict on the side-strength-member material. Confirm the construction against an approved drawing and signed specification before quotation or production.

Short answer for buyers: use this page only to identify the proposed GJYXFCH-1B6a1 configuration. For an RFQ, send the required fiber count, route and installation method, total length, reel length, quantity, marking, destination, and required documentation. BWNFiber must return an approved construction drawing and specification before the item is treated as orderable.

Configuration Status

AttributeDraft valueRelease status
ModelGJYXFCH-1B6a1Supported by supplied product record
Intended applicationFTTH subscriber dropSupported by supplied product record; exact route conditions require review
Fiber gradeG.657.A1 single-modeSupported by supplied product record
Fiber countTBC — source requiredBlocking: the source set covers both 1B6a1 and 2B6a1 and does not provide an unambiguous capacity field
Sheath material / colorLSZH / blackSupported by supplied product record; no separate UV or fire-class claim is established
Cable profile2.0 ± 0.1 × 5.0 ± 0.2 mmSupported by supplied product record, pending source-table alignment review
Side strength membersTBC — drawing and table conflictBlocking: table says two 0.4 mm GFRP members; drawing reportedly labels steel
Messenger1.0 mm phosphated steel wireSupported by supplied table, pending drawing review
Connector / terminationTBC — not stated in supplied recordConfirm bare cable, preconnectorized option, connector type and end-face only if applicable
Packing / reel lengthTBC — source requiredConfirm for quotation
Certification / fire class / UV ratingTBC — source requiredDo not infer from the term “LSZH” or “outdoor”

Why This Configuration Must Be Confirmed Before Ordering

GJYXFCH is a product-family designation used for self-supporting FTTH drop constructions, but family names do not make every supplier’s count, strength members, sheath compound, dimensions or mechanical limits interchangeable. The suffix, drawing revision and approved specification must identify one complete construction. For this record, the fiber count and side-strength-member material remain unresolved, so the product cannot yet be released as a fully orderable SKU.

Provisional Technical Specifications

Values below reproduce the supplied BWNFiber product record after removing duplicate labels and correcting terminology. They remain provisional until engineering validates F0654 against the original source pages.

Construction

ParameterProvisional specificationEvidence status
Fiber gradeG.657.A1 single-modeSupplied record
Fiber countTBC — source requiredBlocking
Nominal cable dimensions2.0 ± 0.1 × 5.0 ± 0.2 mmSupplied record; source-table review required
Side strength membersTable: 2 × 0.4 mm GFRP; drawing: reportedly steelConflict — do not use for order release either as final
Messenger1 × 1.0 mm phosphated steel wireSupplied record; drawing confirmation required
Outer sheathBlack LSZHSupplied record
Fiber colorTBC — confirm against the approved fiber count and color codeThe supplied color list cannot establish capacity

Optical Characteristics

ParameterProvisional specificationEvidence status
Mode field diameter at 1310 nm8.4–9.2 µmSupplied record; confirm table alignment
Mode field diameter at 1550 nm9.3–10.7 µmSupplied record; confirm table alignment and test basis
Cladding diameter125 ± 0.7 µmSupplied record
Core/cladding concentricity error≤0.5 µmSupplied record; terminology normalized
Cladding non-circularity≤0.7%Supplied record
Coating diameter245 ± 5 µmSupplied record
Maximum attenuation at 1310 nm≤0.4 dB/kmSupplied record; not a complete installed-link loss budget
Maximum attenuation at 1550 nm≤0.3 dB/kmSupplied record; not a complete installed-link loss budget

Mechanical Performance

ParameterProvisional specificationEvidence status
Tensile load, long term300 NSupplied record; confirm test method and units
Tensile load, short term600 NSupplied record; confirm test method and units
Crush load, long term1000 NSupplied record; N/100 mm or other test basis not stated
Crush load, short term2200 NSupplied record; N/100 mm or other test basis not stated
Minimum bend radius, static20DSupplied record; D is the finished-cable diameter/profile basis to be confirmed
Minimum bend radius, dynamic40DSupplied record; keep separate from the fiber-level bend specification
Operating, installation and storage temperatureTBC — source requiredNot established in supplied record

The ITU-T G.657 recommendation supports G.657.A1 as a bend-loss-insensitive single-mode fiber category and gives fiber/cable transmission attributes. It does not, by itself, verify this finished cable’s messenger, sheath, tensile, crush, installation or environmental performance. See ITU-T G.657 (08/2024).

Application and Compatibility Conditions

Use this configuration only after the approved construction is matched to the planned FTTH drop route. Confirm:

  1. whether the route is aerial, façade, duct, indoor transition or another method;
  2. the required fiber count and fiber grade;
  3. span, support and clamp conditions for any self-supporting section;
  4. entry-port, routing-space and bend-radius constraints;
  5. local sheath, fire, smoke, halogen, UV and environmental requirements;
  6. termination method and any connector or pigtail requirements;
  7. acceptance tests and documents required by the project.

Do not interpret LSZH as proof of a particular flame-test class, outdoor UV resistance or regional code compliance. Those are separate, evidence-based requirements.

How to Select and Release the Correct Configuration

  1. Identify the route. State the installation method, approximate span or path, indoor/outdoor transitions and environmental exposure.
  2. Confirm the optical requirement. Provide the fiber count, G.657.A1 requirement and any network-owner specification.
  3. Lock the construction. Approve one drawing that identifies the side strength members, messenger, cable profile and sheath.
  4. Lock the mechanical and environmental criteria. Confirm the units, test methods, temperature ranges and any project-specific acceptance limits.
  5. Confirm supply details. State total length, length per reel, quantity, printing, packing, destination and delivery target.
  6. Approve documents before production. Require the final datasheet/drawing revision and agreed inspection or test documents.

Difference From Related BWNFiber Draft Configurations

Draft pageIntended distinctionCannibalization control
P160 — this pageExact GJYXFCH-1B6a1 record; G.657.A1; 2.0 × 5.0 mm; proposed 0.4 mm side membersOwn only the exact SKU/configuration after count and construction are confirmed
P1581F GJYXFCH with 1.0 mm steel messenger and 0.5 mm FRP side membersKeep separate only if the 0.5 mm construction is an approved, commercially distinct SKU
P1451F G.657.A2 with FRP messengerOwn the G.657.A2 / FRP-messenger configuration, not the generic family term
P146 / P1572F configurationsOwn their exact approved two-fiber constructions
P163Broad GJYXFCH/GJYXFCJH/GJYXFCDH family and count comparisonCandidate family/category owner for the broad GJYXFCH and self-supporting bow-type drop cable intent

If engineering cannot prove a stable product distinction between P160 and P158, merge the product truth into the stronger approved SKU record rather than publishing two near-duplicate pages.

RFQ Checklist

Send the following with the inquiry:

  • model reference: GJYXFCH-1B6a1;
  • confirmed fiber count and G.657.A1 requirement;
  • installation method and route description;
  • required side-strength-member and messenger construction;
  • total cable length and length per reel;
  • quantity;
  • jacket color, printing and labeling requirements;
  • destination country, delivery location and requested timeline;
  • required drawing, datasheet, inspection record, test report or compliance document;
  • connector or termination requirement, if any.

Documents to Request Before Release

  • approved product specification;
  • approved construction drawing with a revision number;
  • confirmed fiber count and color code;
  • confirmed mechanical-test units and methods;
  • confirmed environmental limits;
  • project-required fire, smoke, halogen, UV or other compliance evidence;
  • agreed inspection/test record and packing specification.

Related BWNFiber Resources

FAQ

Frequently Asked Questions

What is GJYXFCH-1B6a1?

It is the model reference used in the supplied BWNFiber record for a proposed self-supporting FTTH drop-cable configuration with G.657.A1 fiber, a black LSZH sheath and a nominal 2.0 × 5.0 mm profile. The final fiber count and side-strength-member construction still require engineering confirmation.

Is the fiber count confirmed?

No. The source set referenced by the draft covers both 1B6a1 and 2B6a1, but the delivered record does not contain an unambiguous capacity field. Do not infer the count from the model name or a generic color list.

Are the side strength members GFRP or steel?

The supplied table says two 0.4 mm GFRP members, while the drawing reportedly labels steel. An approved drawing and specification must resolve this conflict before quotation or publication.

Does LSZH prove that the cable is flame-retardant or approved for a specific code?

No. LSZH identifies a sheath-material characteristic; it does not establish a specific flame-test class, UV rating, certification or local-code approval. Request the exact test standard and supporting document required by the project.

Is this cable suitable for every outdoor aerial drop?

Not from the available evidence. Confirm the span, support method, clamps, route, wind/ice exposure, temperature and other environmental requirements against an approved construction and project specification.

What do the 20D and 40D bend values mean?

The provisional record lists 20D for static and 40D for dynamic bend radius, where D refers to the finished cable dimension basis. These cable-handling limits are separate from the bend performance of the G.657.A1 fiber and need engineering confirmation.

Are the attenuation values a complete link-loss budget?

No. The provisional values are cable-fiber attenuation limits at specified wavelengths. A deployed link budget must also account for route length, connectors, splices, splitters and an agreed engineering margin.

Which connector is supplied?

The supplied record does not state a connector or termination. Specify whether the requirement is bare cable, a preconnectorized assembly or another termination, and confirm connector type and end-face only when applicable.

What should be approved before production?

Approve the fiber count, fiber grade, construction drawing, cable dimensions, strength members, messenger, sheath, mechanical and environmental limits, marking, reel length, packing, acceptance tests and document set.

What information is required for a quotation?

Provide the model reference, confirmed fiber count, installation route, construction, total length, reel length, quantity, marking, destination, requested timeline and required documents. This prevents a family name from being quoted as though it were a complete specification.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.