GJYXFCH-1B6a1
GJYXFCH-1B6a1 LSZH Outdoor FTTH Drop Fiber Optic Cable
GJYXFCH-1B6a1 LSZH Outdoor FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Product Summary
The GJYXFCH-1B6a1 is a self-supporting drop-cable configuration under review for FTTH subscriber connections. The supplied product record identifies G.657.A1 single-mode fiber, a black LSZH sheath, a nominal 2.0 × 5.0 mm cable profile, two side strength members, and a 1.0 mm phosphated-steel messenger. The record does not yet establish the fiber count unambiguously, and its drawing and table conflict on the side-strength-member material. Confirm the construction against an approved drawing and signed specification before quotation or production.
Short answer for buyers: use this page only to identify the proposed GJYXFCH-1B6a1 configuration. For an RFQ, send the required fiber count, route and installation method, total length, reel length, quantity, marking, destination, and required documentation. BWNFiber must return an approved construction drawing and specification before the item is treated as orderable.
Configuration Status
| Attribute | Draft value | Release status |
|---|---|---|
| Model | GJYXFCH-1B6a1 | Supported by supplied product record |
| Intended application | FTTH subscriber drop | Supported by supplied product record; exact route conditions require review |
| Fiber grade | G.657.A1 single-mode | Supported by supplied product record |
| Fiber count | TBC — source required | Blocking: the source set covers both 1B6a1 and 2B6a1 and does not provide an unambiguous capacity field |
| Sheath material / color | LSZH / black | Supported by supplied product record; no separate UV or fire-class claim is established |
| Cable profile | 2.0 ± 0.1 × 5.0 ± 0.2 mm | Supported by supplied product record, pending source-table alignment review |
| Side strength members | TBC — drawing and table conflict | Blocking: table says two 0.4 mm GFRP members; drawing reportedly labels steel |
| Messenger | 1.0 mm phosphated steel wire | Supported by supplied table, pending drawing review |
| Connector / termination | TBC — not stated in supplied record | Confirm bare cable, preconnectorized option, connector type and end-face only if applicable |
| Packing / reel length | TBC — source required | Confirm for quotation |
| Certification / fire class / UV rating | TBC — source required | Do not infer from the term “LSZH” or “outdoor” |
Why This Configuration Must Be Confirmed Before Ordering
GJYXFCH is a product-family designation used for self-supporting FTTH drop constructions, but family names do not make every supplier’s count, strength members, sheath compound, dimensions or mechanical limits interchangeable. The suffix, drawing revision and approved specification must identify one complete construction. For this record, the fiber count and side-strength-member material remain unresolved, so the product cannot yet be released as a fully orderable SKU.
Provisional Technical Specifications
Values below reproduce the supplied BWNFiber product record after removing duplicate labels and correcting terminology. They remain provisional until engineering validates F0654 against the original source pages.
Construction
| Parameter | Provisional specification | Evidence status |
|---|---|---|
| Fiber grade | G.657.A1 single-mode | Supplied record |
| Fiber count | TBC — source required | Blocking |
| Nominal cable dimensions | 2.0 ± 0.1 × 5.0 ± 0.2 mm | Supplied record; source-table review required |
| Side strength members | Table: 2 × 0.4 mm GFRP; drawing: reportedly steel | Conflict — do not use for order release either as final |
| Messenger | 1 × 1.0 mm phosphated steel wire | Supplied record; drawing confirmation required |
| Outer sheath | Black LSZH | Supplied record |
| Fiber color | TBC — confirm against the approved fiber count and color code | The supplied color list cannot establish capacity |
Optical Characteristics
| Parameter | Provisional specification | Evidence status |
|---|---|---|
| Mode field diameter at 1310 nm | 8.4–9.2 µm | Supplied record; confirm table alignment |
| Mode field diameter at 1550 nm | 9.3–10.7 µm | Supplied record; confirm table alignment and test basis |
| Cladding diameter | 125 ± 0.7 µm | Supplied record |
| Core/cladding concentricity error | ≤0.5 µm | Supplied record; terminology normalized |
| Cladding non-circularity | ≤0.7% | Supplied record |
| Coating diameter | 245 ± 5 µm | Supplied record |
| Maximum attenuation at 1310 nm | ≤0.4 dB/km | Supplied record; not a complete installed-link loss budget |
| Maximum attenuation at 1550 nm | ≤0.3 dB/km | Supplied record; not a complete installed-link loss budget |
Mechanical Performance
| Parameter | Provisional specification | Evidence status |
|---|---|---|
| Tensile load, long term | 300 N | Supplied record; confirm test method and units |
| Tensile load, short term | 600 N | Supplied record; confirm test method and units |
| Crush load, long term | 1000 N | Supplied record; N/100 mm or other test basis not stated |
| Crush load, short term | 2200 N | Supplied record; N/100 mm or other test basis not stated |
| Minimum bend radius, static | 20D | Supplied record; D is the finished-cable diameter/profile basis to be confirmed |
| Minimum bend radius, dynamic | 40D | Supplied record; keep separate from the fiber-level bend specification |
| Operating, installation and storage temperature | TBC — source required | Not established in supplied record |
The ITU-T G.657 recommendation supports G.657.A1 as a bend-loss-insensitive single-mode fiber category and gives fiber/cable transmission attributes. It does not, by itself, verify this finished cable’s messenger, sheath, tensile, crush, installation or environmental performance. See ITU-T G.657 (08/2024).
Application and Compatibility Conditions
Use this configuration only after the approved construction is matched to the planned FTTH drop route. Confirm:
- whether the route is aerial, façade, duct, indoor transition or another method;
- the required fiber count and fiber grade;
- span, support and clamp conditions for any self-supporting section;
- entry-port, routing-space and bend-radius constraints;
- local sheath, fire, smoke, halogen, UV and environmental requirements;
- termination method and any connector or pigtail requirements;
- acceptance tests and documents required by the project.
Do not interpret LSZH as proof of a particular flame-test class, outdoor UV resistance or regional code compliance. Those are separate, evidence-based requirements.
How to Select and Release the Correct Configuration
- Identify the route. State the installation method, approximate span or path, indoor/outdoor transitions and environmental exposure.
- Confirm the optical requirement. Provide the fiber count, G.657.A1 requirement and any network-owner specification.
- Lock the construction. Approve one drawing that identifies the side strength members, messenger, cable profile and sheath.
- Lock the mechanical and environmental criteria. Confirm the units, test methods, temperature ranges and any project-specific acceptance limits.
- Confirm supply details. State total length, length per reel, quantity, printing, packing, destination and delivery target.
- Approve documents before production. Require the final datasheet/drawing revision and agreed inspection or test documents.
Difference From Related BWNFiber Draft Configurations
| Draft page | Intended distinction | Cannibalization control |
|---|---|---|
| P160 — this page | Exact GJYXFCH-1B6a1 record; G.657.A1; 2.0 × 5.0 mm; proposed 0.4 mm side members | Own only the exact SKU/configuration after count and construction are confirmed |
| P158 | 1F GJYXFCH with 1.0 mm steel messenger and 0.5 mm FRP side members | Keep separate only if the 0.5 mm construction is an approved, commercially distinct SKU |
| P145 | 1F G.657.A2 with FRP messenger | Own the G.657.A2 / FRP-messenger configuration, not the generic family term |
| P146 / P157 | 2F configurations | Own their exact approved two-fiber constructions |
| P163 | Broad GJYXFCH/GJYXFCJH/GJYXFCDH family and count comparison | Candidate family/category owner for the broad GJYXFCH and self-supporting bow-type drop cable intent |
If engineering cannot prove a stable product distinction between P160 and P158, merge the product truth into the stronger approved SKU record rather than publishing two near-duplicate pages.
RFQ Checklist
Send the following with the inquiry:
- model reference: GJYXFCH-1B6a1;
- confirmed fiber count and G.657.A1 requirement;
- installation method and route description;
- required side-strength-member and messenger construction;
- total cable length and length per reel;
- quantity;
- jacket color, printing and labeling requirements;
- destination country, delivery location and requested timeline;
- required drawing, datasheet, inspection record, test report or compliance document;
- connector or termination requirement, if any.
Documents to Request Before Release
- approved product specification;
- approved construction drawing with a revision number;
- confirmed fiber count and color code;
- confirmed mechanical-test units and methods;
- confirmed environmental limits;
- project-required fire, smoke, halogen, UV or other compliance evidence;
- agreed inspection/test record and packing specification.
Related BWNFiber Resources
- Compare the broader FTTH drop cable product range when the model or construction has not yet been selected.
- Use the fiber optic cable selection page for FTTx projects for route- and cable-family selection before narrowing to an exact SKU.
- Review Standard FTTH Rollout Solution B when the cable is part of a wider residential ODN design rather than a standalone purchase.
- Read the ODN overview for the role of drop cables, splitters, connectors and distribution equipment in the access network.
Frequently Asked Questions
What is GJYXFCH-1B6a1?
It is the model reference used in the supplied BWNFiber record for a proposed self-supporting FTTH drop-cable configuration with G.657.A1 fiber, a black LSZH sheath and a nominal 2.0 × 5.0 mm profile. The final fiber count and side-strength-member construction still require engineering confirmation.
Is the fiber count confirmed?
No. The source set referenced by the draft covers both 1B6a1 and 2B6a1, but the delivered record does not contain an unambiguous capacity field. Do not infer the count from the model name or a generic color list.
Are the side strength members GFRP or steel?
The supplied table says two 0.4 mm GFRP members, while the drawing reportedly labels steel. An approved drawing and specification must resolve this conflict before quotation or publication.
Does LSZH prove that the cable is flame-retardant or approved for a specific code?
No. LSZH identifies a sheath-material characteristic; it does not establish a specific flame-test class, UV rating, certification or local-code approval. Request the exact test standard and supporting document required by the project.
Is this cable suitable for every outdoor aerial drop?
Not from the available evidence. Confirm the span, support method, clamps, route, wind/ice exposure, temperature and other environmental requirements against an approved construction and project specification.
What do the 20D and 40D bend values mean?
The provisional record lists 20D for static and 40D for dynamic bend radius, where D refers to the finished cable dimension basis. These cable-handling limits are separate from the bend performance of the G.657.A1 fiber and need engineering confirmation.
Are the attenuation values a complete link-loss budget?
No. The provisional values are cable-fiber attenuation limits at specified wavelengths. A deployed link budget must also account for route length, connectors, splices, splitters and an agreed engineering margin.
Which connector is supplied?
The supplied record does not state a connector or termination. Specify whether the requirement is bare cable, a preconnectorized assembly or another termination, and confirm connector type and end-face only when applicable.
What should be approved before production?
Approve the fiber count, fiber grade, construction drawing, cable dimensions, strength members, messenger, sheath, mechanical and environmental limits, marking, reel length, packing, acceptance tests and document set.
What information is required for a quotation?
Provide the model reference, confirmed fiber count, installation route, construction, total length, reel length, quantity, marking, destination, requested timeline and required documents. This prevents a family name from being quoted as though it were a complete specification.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.