GJYXCH
GJYXCH 2F G.657.A2 Steel-Wire LSZH FTTH Drop Fiber Optic Cable
GJYXCH 2F G.657.A2 Steel-Wire LSZH FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Product Value Summary
This GJYXCH configuration is a 2-fiber, G.657.A2 single-mode FTTH drop cable with an LSZH outer sheath, two steel-wire strength members, and an integrated steel messenger. The supplied internal draft identifies a nominal cable profile of 1.95 ± 0.05 × 5.2 ± 0.2 mm. Use this page to verify the exact configuration before requesting a datasheet, sample, or quotation; do not substitute a broader GJYXCH family specification.
Buyer check: send the full configuration, route, required length, drum or roll length, quantity, marking, delivery destination, and required approval documents. The finished-cable bend limit, project fire rating, UV/weathering requirement, aerial span, clamp compatibility, and short-term mechanical values remain subject to BWNFiber engineering confirmation.
Notice
The listed specifications are sourcing-reference values from the supplied internal draft and are subject to approval against the controlled BWNFiber datasheet. They are not a performance guarantee or a substitute for project engineering review.
Key Configuration
| Selection field | This page covers | Procurement note |
|---|---|---|
| Model family | GJYXCH | Model names alone do not identify one interchangeable construction. |
| Fiber count | 2F | Different counts require a separate configuration review. |
| Fiber grade | ITU-T G.657.A2 single-mode | Keep the fiber grade on the purchase specification. |
| Cable construction | Self-supporting FTTH drop cable with steel messenger | Confirm the route, span, sag, wind exposure, clamps, and attachment points. |
| Strength members | Steel wire, 0.5 mm | Two members are shown in the supplied construction data. |
| Messenger | Steel wire, 1.0 mm | Confirm clamp and support-hardware compatibility. |
| Jacket | Black LSZH | LSZH alone does not prove a specific fire, UV, weathering, or building-code rating. |
| Cable profile | 1.95 ± 0.05 × 5.2 ± 0.2 mm | Verify against entry ports, seals, clamps, and routing space. |
| Cable weight | 20 kg/km | Confirm the approved datasheet revision before order release. |
Where This Configuration Fits
This page is for buyers evaluating a specific 2F GJYXCH drop-cable configuration for an FTTH subscriber route. The integrated messenger indicates a self-supporting aerial construction, but the supplied draft does not establish an approved span class or site design. Before selection, define:
- the distribution point and subscriber endpoint;
- every aerial, outdoor, wall-entry, and indoor section;
- the required span, sag, wind exposure, clamps, and attachment hardware;
- local fire, smoke, halogen, UV, and weathering requirements;
- the cable entry, seal, duct, and bend-control dimensions; and
- whether the cable is supplied unterminated or with a separately approved termination.
Do not use this page as evidence of direct-burial suitability, armor, water blocking, rodent protection, connector compatibility, or a particular building-code approval. Those properties are not established by the supplied record.
Technical Specifications
Cable Construction
| Component or parameter | Supplied value | Release status |
|---|---|---|
| Fiber count | 2F | Provisionally supported; verify against approved datasheet |
| Fiber type | G.657.A2 | Provisionally supported; verify against approved datasheet |
| Outer sheath material | LSZH | Provisionally supported; project rating TBC |
| Outer sheath color | Black | Provisionally supported |
| Cable profile | 1.95 ± 0.05 × 5.2 ± 0.2 mm | Provisionally supported |
| Strength-member material | Steel wire | Provisionally supported |
| Strength-member diameter | 0.5 mm | Provisionally supported |
| Self-supporting messenger material | Steel wire | Provisionally supported |
| Messenger diameter | 1.0 mm | Provisionally supported |
| Cable weight | 20 kg/km | Provisionally supported |
Optical Characteristics
| Parameter | Supplied value | Boundary |
|---|---|---|
| Attenuation at 1310 nm | ≤ 0.40 dB/km | Cable-fiber value; not a complete link-loss budget |
| Attenuation at 1550 nm | ≤ 0.30 dB/km | Cable-fiber value; not a connector or splice loss |
| Cable cutoff wavelength | ≤ 1260 nm | Verify test method and approved datasheet revision |
| Cladding diameter | 124.8 ± 0.7 μm | Provisionally supported |
| Cladding non-circularity | ≤ 0.7% | Provisionally supported |
| Coating diameter | 245 ± 5 μm | Provisionally supported |
| Core-to-cladding concentricity error | ≤ 0.5 μm | Provisionally supported |
| Fiber curl radius | ≥ 4 m | Fiber property; not the finished-cable minimum bend radius |
The current in-force ITU-T G.657 recommendation describes G.657.A2 as a bend-loss-insensitive single-mode fiber category. That fiber designation does not, by itself, establish the finished cable’s installation or service bend radius.
Mechanical and Environmental Data
| Parameter | Supplied value | Release status |
|---|---|---|
| Installation temperature | -10 to +60 °C | Provisionally supported |
| Operation and transport temperature | -20 to +70 °C | Provisionally supported; separate operation from transport in the approved datasheet |
| Storage temperature | -20 to +70 °C | Provisionally supported |
| Tensile strength, long term | 300 N | Provisionally supported |
| Tensile strength, short term | TBC — source-row assignment requires confirmation | do not use for order release a value until engineering confirms the row label |
| Crush load, long term | 500 N/100 mm | Provisionally supported |
| Crush load, short term | TBC — source-row assignment requires confirmation | do not use for order release a value until engineering confirms the row label |
| Finished-cable minimum bend radius | TBC — conflicting long/static and short/dynamic values in source review | Engineering approval required |
Interfaces and Connector Options
The supplied record describes bulk cable construction and does not confirm a connector, polish, pre-terminated assembly, or optical interface. Specify one of the following in the RFQ:
- Unterminated bulk cable: confirm reel or drum length, preparation method, and termination responsibility.
- Pre-terminated option: TBC — request a separate drawing and confirm connector type, polish, end length, pulling protection, and test limits.
Do not infer SC/APC, SC/UPC, LC, or equipment compatibility from the GJYXCH model name.
How to Select the Correct Configuration
- Confirm the route. State indoor, outdoor, aerial, wall-entry, and protected sections.
- Lock the fiber plan. Confirm 2F and G.657.A2 against the ODN design and reserve-fiber requirement.
- Approve the cable profile. Match 1.95 × 5.2 mm to the clamp, seal, entry port, duct, and handling tools.
- Review aerial mechanics. Provide span, sag, wind exposure, attachment points, and required hardware; request an engineering-approved load limit.
- Confirm the jacket requirement. State the required fire, smoke, halogen, UV, weathering, and local-code evidence instead of relying on “LSZH” alone.
- Close the acceptance package. Request the controlled datasheet, drawing, applicable test methods, inspection documents, marking, packing, and quotation.
Differences From Related BWNFiber Pages
| Page | Role | What belongs there | What belongs on this page |
|---|---|---|---|
| FTTH Drop Cable category | Commercial selection | Compare indoor, aerial, duct, armored, flat, and round families | Do not repeat the full category guide |
| Aerial Self-Support FTTH Drop Cable | Family browsing | Compare 1F–12F and alternative strength/support systems | Exact 2F G.657.A2 steel/LSZH configuration only |
| Butterfly Flat FTTH Drop Cable | Non-messenger flat family | Indoor or non-self-supporting flat-drop options | Integrated steel-messenger construction |
| This GJYXCH page | Exact-model validation | Exact configuration, technical limits, documents, and RFQ inputs | Keep broad “FTTH drop cable” selection intent out |
Testing and Quality-Control Documents to Request
No completed test report was supplied with this task. Before technical approval or a bulk order, ask BWNFiber to identify the document revision and provide, where applicable:
- the approved product datasheet and dimensional drawing;
- the fiber certificate or declared G.657.A2 source evidence;
- attenuation test method, wavelength, sampling rule, and acceptance limit;
- tensile and crush test method, duration, load, and acceptance criteria;
- finished-cable bend test method and confirmed static/dynamic limits;
- temperature-cycling or environmental test method and acceptance criteria;
- jacket material declaration plus any project-required fire, smoke, halogen, UV, or weathering evidence;
- length, marking, packing, and inspection records for the ordered lot.
These are document requests, not claims that every listed test or certificate already exists.
Packaging and Procurement Information
| Procurement field | Required input or status |
|---|---|
| Total length | Buyer to specify |
| Length per drum or roll | Buyer to specify; available packing TBC |
| Quantity | Buyer to specify |
| Cable marking | Buyer to provide or approve |
| Destination | Buyer to specify |
| MOQ | TBC — quotation required |
| Lead time | TBC — quotation required |
| Price | TBC — quotation required |
| Warranty | TBC — source required |
| Export packing | TBC — confirm for destination and handling method |
Information Required for an RFQ
Send the following as one configuration checksum:
GJYXCH / 2F / G.657.A2 / black LSZH / two 0.5 mm steel strength members / 1.0 mm steel messenger / 1.95 ± 0.05 × 5.2 ± 0.2 mm cable profile
Then add:
- route and installation method;
- aerial span, sag, wind, clamp, and attachment conditions;
- required fire, smoke, halogen, UV, weathering, and local-code evidence;
- total length and length per drum or roll;
- quantity, marking, packing, and destination;
- unterminated or pre-terminated requirement;
- datasheet, drawing, test-report, inspection, and sample requirements.
Datasheet, Drawing, and Test-Report Area
- Verified datasheet: TBC — controlled source required
- Dimensional drawing: TBC — controlled source required
- Test report: TBC — exact product/lot and acceptance limits required
- Sample request: Subject to quotation and BWNFiber confirmation
Frequently Asked Questions
What exact configuration does this page cover?
It covers a GJYXCH 2F cable with G.657.A2 single-mode fiber, black LSZH sheath, two 0.5 mm steel strength members, a 1.0 mm steel messenger, and a supplied cable profile of 1.95 ± 0.05 × 5.2 ± 0.2 mm. Confirm the controlled datasheet before order release.
Is this a self-supporting aerial drop cable?
The supplied construction includes an integrated steel messenger, which identifies a self-supporting drop-cable design. The approved span, sag, wind, tension, clamps, and attachment method remain TBC and require project review.
Does LSZH mean the cable is approved for every indoor or outdoor route?
No. LSZH identifies a jacket-material characteristic; it does not, by itself, prove a particular fire classification, building-code approval, UV resistance, weathering performance, water blocking, or direct-burial suitability.
What attenuation values are listed?
The supplied draft lists ≤ 0.40 dB/km at 1310 nm and ≤ 0.30 dB/km at 1550 nm. These are cable-fiber attenuation values, not a complete link-loss budget with splices, connectors, splitters, and engineering margin.
Does G.657.A2 define the finished-cable bend radius?
No. G.657.A2 describes the optical fiber category and its bend-loss performance. The finished cable’s static and dynamic bend limits depend on the complete construction and must be confirmed in the approved cable datasheet.
Which load values can be used for design approval?
The supplied draft provisionally lists 300 N long-term tensile strength and 500 N/100 mm long-term crush load. The short-term source-row assignments and bend-radius values require engineering confirmation, so do not release a design from this draft.
Can this cable be ordered with SC/APC or another connector?
The supplied record does not confirm a pre-terminated option or connector interface. Request a separate drawing and test limits for any connectorized assembly.
What must be checked against clamps and entry ports?
Check the complete 1.95 × 5.2 mm profile, messenger diameter, cable orientation, grip range, seal range, bend control, and pulling method. Do not approve hardware from a generic GJYXCH family name alone.
What documents should accompany a technical approval?
Request the controlled datasheet, dimensional drawing, applicable test methods and acceptance limits, jacket declarations required by the project, and lot-specific inspection or test records where contracted.
What should be included in the quotation request?
Send the full configuration checksum, route and installation method, mechanical and environmental requirements, total and per-drum length, quantity, marking, packing, destination, termination requirement, and document list.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.