FTTH Drop Cable

GJXH 1F G.657.A1 Steel-Wire LSZH FTTH Drop Fiber Optic Cable

GJXH 1F G.657.A1 Steel-Wire LSZH FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

GJXH

Product Value Summary

This page identifies one proposed GJXH drop-cable configuration: 1 fiber, G.657.A1 single-mode fiber, steel-wire strength members, an LSZH sheath and a listed cable size of 1.95 ± 0.1 × 2.95 ± 0.1 mm. It is intended to help a buyer compare a quotation against one exact configuration rather than approve a cable from the GJXH family name alone.

Product specification notice: The current BWNFiber record is not yet a controlled release datasheet. All listed figures are for sourcing reference only, not a guarantee, and remain subject to confirmation against the controlled construction drawing and datasheet. Confirm the installation environment, mechanical limits, temperature definitions and test requirements before sample approval or purchase-order release.

Primary action: Request the controlled P151 datasheet and configuration review.

Short Answer for Buyers

Use this page only when the required cable is the proposed P151 configuration: GJXH, 1F, G.657.A1, steel-wire strength members, LSZH sheath and 1.95 ± 0.1 × 2.95 ± 0.1 mm listed dimensions. Do not substitute a GJXFH, GJYXCH, FRP-strengthened or self-supporting cable merely because it is also sold as an FTTH drop cable. Before ordering, match the cable to the complete route and confirm the controlled drawing and test criteria.

Key Features

  • Exact page scope: one proposed GJXH 1F configuration, not the complete FTTH drop-cable range.
  • Fiber: G.657.A1 single-mode fiber, subject to controlled datasheet confirmation.
  • Strength system: steel-wire strength members shown in the supplied cross-section image; quantity and dimensional callouts require drawing confirmation.
  • Sheath: LSZH material is listed in the internal record. The applicable fire, smoke or building-code rating is TBC — source required.
  • Listed cable size: 1.95 ± 0.1 × 2.95 ± 0.1 mm, subject to measurement convention and drawing confirmation.
  • Procurement boundary: cable length, length per reel or drum, marking, packing, test records, price, MOQ and lead time are quotation-specific and not established by this page.

Configuration Status

Configuration fieldCurrent P151 recordRelease status
ModelGJXHConfirm on controlled datasheet
Fiber count1FConfirm on controlled datasheet
Fiber categoryG.657.A1Confirm fiber supplier and certificate/report scope
Strength-member materialSteel wireConfirm construction drawing and quantity
Listed strength-member diameter0.5 mmTBC — source required; confirm tolerance and whether the value applies to each member
Sheath materialLSZHConfirm the exact compound and any claimed rating separately
Listed cable dimensions1.95 ± 0.1 × 2.95 ± 0.1 mmTBC — source required; confirm width/height convention
Listed cable weight9.5 ± 2 kg/kmTBC — source required; confirm finished-cable tolerance
Cable colorTBC — source requiredBuyer and product owner to confirm
Indoor/outdoor route approvalTBC — source requiredDo not infer from GJXH or LSZH alone
Unterminated or pre-terminatedTBC — source requiredThis draft does not establish connector ends

Provisional Technical Specifications

The values below reproduce the current P151 internal record for engineering review. They are not a released specification and must not be published as approved product claims until checked against the original source worksheet and controlled datasheet.

Cable Construction

ParameterProvisional valueVerification required
Fiber count1FConfirm source cell and drawing
Fiber categoryG.657.A1Confirm source cell and fiber documentation
Sheath materialLSZHConfirm material declaration and project rating
Strength-member materialSteel wireConfirm drawing
Strength-member diameter0.5 mmConfirm quantity, tolerance and unit
Finished cable size1.95 ± 0.1 × 2.95 ± 0.1 mmConfirm dimension order and tolerance
Finished cable weight9.5 ± 2 kg/kmConfirm test or calculation method

Optical Characteristics

Parameter / conditionProvisional valueVerification required
Attenuation at 1310 nm≤ 0.4 dB/kmConfirm test method, sample basis and released limit
Attenuation at 1550 nm≤ 0.3 dB/kmConfirm test method, sample basis and released limit
Maximum attenuation difference, 1285–1330 nm≤ 0.03 dB/kmConfirm source heading and method
Maximum attenuation difference, 1525–1575 nm≤ 0.02 dB/kmConfirm source heading and method
Zero-dispersion wavelength1300–1324 nmConfirm applicable fiber specification
Maximum zero-dispersion slope≤ 0.092 ps/(nm²·km)Confirm source unit and notation
Cable cut-off wavelength≤ 1260 nmConfirm symbol and method
Effective group index at 1310 nm1.466Confirm supplier documentation
Effective group index at 1550 nm1.467Confirm supplier documentation
Point discontinuity at 1310 nm≤ 0.05 dBConfirm definition and test method
Point discontinuity at 1550 nm≤ 0.05 dBConfirm definition and test method
Cladding diameter124.8 ± 0.7 µmConfirm source value against current approved fiber data
Cladding non-circularity≤ 0.7%Confirm source value
Coating diameter245 ± 5 µmConfirm source value
Coating–cladding concentricity error≤ 12.0 µmConfirm terminology and source value
Coating non-circularity≤ 6.0%Confirm source value
Core–cladding concentricity error≤ 0.5 µmConfirm source value
Curl radius≥ 4 mConfirm source definition and method
Mode field diameterTBC — source requiredThe source transcription used nm for a diameter value; do not use for order release until corrected by engineering
Polarization mode dispersionTBC — source requiredThe source transcription omitted units and mixed individual/statistical values; do not use for order release until corrected

The current in-force ITU-T G.657 (08/2024) recommendation specifies G.657 fiber attributes and cable-level attenuation/PMD concepts. It does not validate this finished cable’s construction, mechanical limits, sheath rating or manufacturing test results.

Mechanical and Environmental Performance

Parameter / conditionProvisional valueVerification required
Installation temperature−20 to +60 °CConfirm that this is an installation, not operating, range
Operation and transport temperature−20 to +70 °CSeparate operation, storage and transport values in the controlled datasheet
Minimum bend radius, long term10DConfirm whether D means finished-cable diameter or another defined dimension
Minimum bend radius, short term20DConfirm installation/load condition
Tensile load, long term100 NConfirm method and acceptance criterion
Tensile load, short term230 NConfirm method and acceptance criterion
Crush load1000 N/100 mmConfirm duration, method and acceptance criterion

Interfaces and Connector Options

This record describes a bulk drop cable and does not establish a connector interface, polish, pigtail, fast connector or pre-terminated end. If termination is required, specify each end separately and confirm that the chosen connector, boot, protection hardware and field method accept the finished cable dimensions.

Interface fieldBuyer input
End AUnterminated / connector type and polish / splice input — TBC
End BUnterminated / connector type and polish / splice input — TBC
Pulling protectionTBC — source required
Connector test limitsTBC — source required

Fiber Type and Configuration Boundary

G.657.A1 identifies a bend-loss-insensitive single-mode fiber category. It does not replace the finished cable’s documented bend radius, pulling tension, crush limit or route approval. A G.657.A2, G.652.D or other fiber grade is a different configuration and should not be substituted without approval.

This page is limited to 1F. Other fiber counts, FRP members, messenger constructions, round cables, armored cables and self-supporting cables belong to different configurations or product families.

Compatibility and Application Conditions

The current record supports the general use case FTTH subscriber connections. The following approval conditions remain open:

  • Exact indoor, outdoor, riser, wall, duct or aerial route: TBC — source required.
  • Fire, smoke, halogen, UV, moisture, corrosion or rodent rating: TBC — source required.
  • Terminal, closure, outlet, clamp, seal and connector compatibility: verify by dimensions and interface drawings.
  • GPON, XGS-PON or point-to-point use: confirm wavelength plan, loss budget, splices, connectors and equipment separately; the cable-fiber attenuation is not the complete link budget.
  • Local code and project specification: buyer/engineer approval required.

How to Select the Correct Configuration

  1. Map the route. Mark every indoor, outdoor, wall, duct and aerial section between the distribution point and subscriber endpoint.
  2. Confirm the cable role. Use P151 only for an exact GJXH 1F steel-wire LSZH configuration; use the FTTH Drop Cable category for family selection.
  3. Verify dimensions and interfaces. Check the cable against entries, seals, clamps, termination hardware and tools.
  4. Set mechanical and environmental requirements. State pulling tension, installed load, crush exposure, minimum bend radius and temperature conditions.
  5. Define optical acceptance. State wavelengths, length basis, test method and acceptance limits for the finished cable or installed link.
  6. Lock the controlled evidence. Approve the part number, drawing revision, datasheet revision, sample/test records and permitted deviations before the purchase order.
  7. Complete the commercial fields. Provide total length, length per reel or drum, quantity, marking, packing, destination and required documents.

Differences From Related BWNFiber Pages

Page or configurationCorrect roleDifference from P151
FTTH Drop Cable categoryFamily discovery and route-based selectionOwns broad terms such as “FTTH drop cable” and comparison across cable families
Butterfly Flat FTTH Drop CableGeneric butterfly-flat family/product pageCovers multiple fiber counts and strength-member options; it should not inherit P151-only dimensions or limits
P152 GJXH 1F LSZH Indoor FTTH Drop CablePotential duplicate / variant recordSame model, fiber count and LSZH theme; publish separately only if a controlled drawing proves a materially different configuration and business role
GJXFH 1F G.657.A1 FRP LSZH cableSeparate material configurationFRP strength members instead of P151’s steel-wire configuration
GJYXCH self-supporting drop cableSeparate route and support configurationIncludes a self-supporting/messenger design; do not use it as a substitute for P151

Use Cases

Use this configuration only after engineering confirms that the exact P151 construction is approved for the planned subscriber route. Potential use cases such as indoor wall routes, risers, corridors or protected access pathways remain TBC — source required; they are not established by the supplied P151 record alone.

Testing and Quality-Control Requirements

No P151-specific production test plan or released report was supplied with this task. Add the following only after the product owner defines the scope:

Approval itemRequired evidence
Incoming fiber identityFiber supplier record or approved certificate tied to the lot
Finished dimensions and weightInspection record with tolerance and sampling plan
AttenuationMethod, wavelength, length basis, equipment and acceptance limit
Tensile and crushApplicable test method, load/duration and post-test acceptance criterion
Bend performanceFinished-cable method and limit; do not substitute the fiber-category radius
Temperature performanceDefined cycle/range and acceptance criterion
Batch traceabilityLot, reel/drum number, marking and inspection record

Do not promise OTDR, insertion-loss, return-loss, IEC compliance or a certificate unless the quotation and controlled quality plan explicitly include it.

Packaging and Procurement Information

FieldStatus
Standard reel/drum lengthTBC — source required
Minimum order quantityTBC — commercial confirmation required
PriceTBC — quotation required
Lead timeTBC — quotation required
Packing methodTBC — source required
Sheath marking formatBuyer to specify; product owner to confirm capability
Datasheet, drawing and test recordsAvailability and revision TBC
WarrantyTBC — commercial confirmation required

Required Information for an RFQ

Copy this checklist into the inquiry:

  • Product reference: P151 — GJXH 1F G.657.A1 steel-wire LSZH drop cable
  • Route: indoor / outdoor / wall / duct / aerial / other
  • Required cable dimensions and tolerance
  • Total length and length per reel or drum
  • Quantity
  • End condition: unterminated or specified connectors
  • Required sheath color and marking
  • Pulling, installed, bend, crush and temperature requirements
  • Required optical test wavelengths and acceptance criteria
  • Required datasheet, drawing, sample, test report or material declaration
  • Packing, destination and requested delivery date

Document Download Area

  • Controlled P151 datasheet: TBC — source required
  • Controlled cross-section drawing: TBC — source required
  • Sample approval record: TBC — source required
  • Lot-specific test report: TBC — source required
  • LSZH material/rating declaration: TBC — source required

do not use for order release placeholder links as if the documents already exist.

RFQ / CTA

Request the P151 Controlled Datasheet and Configuration Review

Send BWNFiber the route, required lengths, quantity, cable-entry dimensions, end condition and approval-document list. Ask the product owner to return the current P151 datasheet, drawing revision and any included test evidence before quotation approval.

Send the P151 configuration for review

Image Use

UseExisting fileRecommended alt textCaptionQA requirement
Product cross-section / identification800logo/FTTH GJXH 1F.webpGJXH 1F FTTH drop cable cross-section with steel-wire strength membersReference cross-section for the proposed P151 GJXH 1F steel-wire configuration; confirm the controlled drawing before approval.Keep the visible BWinners watermark; confirm that the image belongs to P151 and that labels match the approved drawing

No new product photo, test-report image, certification image or exact technical drawing was generated for this draft.

Internal Links

FAQ

Frequently Asked Questions

What does this P151 page cover?

It covers one proposed GJXH configuration: 1F, G.657.A1 fiber, steel-wire strength members, an LSZH sheath and listed dimensions of 1.95 ± 0.1 × 2.95 ± 0.1 mm. The controlled datasheet must confirm these fields before release.

Is P151 the same product as every GJXH drop cable?

No. GJXH is a family/model designation used with different fiber counts, dimensions and detailed specifications. Approve the exact part number and drawing rather than the family name alone.

Is P151 the same as the P152 GJXH 1F LSZH cable?

That has not been proved. Their page roles and specifications overlap materially. BWNFiber should compare the original drawings and source files, then either merge them under one canonical owner or document the configuration difference.

Does G.657.A1 determine the finished cable bend radius?

No. G.657.A1 describes fiber attributes, including bend-loss performance. The finished cable’s minimum bend radius and installation limits must come from the approved cable datasheet and route method.

Does LSZH prove compliance with a building fire code?

No. LSZH identifies a sheath-material characteristic. A project may require a named fire, smoke or cable classification and supporting evidence for the exact finished cable.

Can the listed attenuation values be used as the complete FTTH link budget?

No. Cable-fiber attenuation does not include connector, splice, splitter and engineering margins. Build the link budget from the complete route and the applicable network design.

Is this cable approved for outdoor or aerial installation?

Not from the supplied P151 evidence. Confirm the declared installation environment, UV/moisture ratings, support method and hardware before using it outdoors or across an aerial span.

Which connectors are supplied?

No connector option is established in the current record. State whether the cable must be unterminated or pre-terminated and define both ends in the RFQ.

What should be verified on a sample?

Verify the part number, cross-section, dimensions, strength-member construction, sheath and marking against the approved drawing. Define optical and mechanical tests before the sample is produced so the acceptance record matches the project.

What information is needed for a quotation?

Provide the exact configuration, route, total length, length per reel or drum, quantity, end condition, marking, packing, destination and required approval documents. Add project-specific mechanical, environmental and test requirements.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.