FTTH Drop Cable

GJXFH-4B6a1 G.657.A1 Indoor FTTH Drop Fiber Optic Cable

GJXFH-4B6a1 G.657.A1 Indoor FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

GJXFH-4B6a1

Product Value Summary

The BWNFiber GJXFH-4B6a1 record describes a compact indoor FTTH drop cable with G.657.A1 single-mode fiber, an LSZH outer jacket and a nominal cable profile of 2.0 ± 0.1 × 3.0 ± 0.1 mm. It is intended for the subscriber-side indoor segment of an FTTH connection.

Two order-critical details are not yet cleared for publication: the explicit fiber count and the relationship between the GJXFH model designation and the source-recorded two steel-wire strength members. Confirm both against the current approved drawing or datasheet before using this page for a quotation.

Buyer short answer: use this page only to identify the proposed G.657.A1, LSZH, 2 × 3 mm indoor-drop configuration. It is not yet an orderable specification. Ask BWNFiber to confirm the fiber count, strength-member construction and approved source document first.

Configuration Status at a Glance

Order attributeCurrent recordRelease status
ModelGJXFH-4B6a1Confirm against approved drawing or datasheet
Fiber countTBC — source requiredBlocking; do not infer from the model code, color list or image
Fiber gradeG.657.A1Retained from local BWNFiber record
Cable applicationIndoor FTTH subscriber connectionRetained from local BWNFiber record
Outer jacketLSZH; black or white recordedConfirm color and any required fire-performance classification
Cable size2.0 ± 0.1 × 3.0 ± 0.1 mmRetained from local BWNFiber record
Strength membersTwo Φ0.4 mm steel wires recordedBlocking; conflicts with BWNFiber category naming, which describes GJXFH as FRP and GJXH as steel-wire construction
Connector interfaceNone documentedBare-cable page unless a separate pre-terminated assembly is approved
Reel/roll lengthTBC — source requiredState required length in the RFQ
Compliance / flame ratingTBC — source requiredLSZH material wording is not a fire-classification claim

Key Features

  • Exact-model scope: GJXFH-4B6a1, subject to model/construction confirmation.
  • Fiber grade: G.657.A1 bend-insensitive single-mode fiber.
  • Jacket: LSZH material is recorded; no specific flame-test classification is currently evidenced.
  • Cable profile: 2.0 ± 0.1 × 3.0 ± 0.1 mm.
  • Indoor FTTH use: intended for subscriber-side indoor routing, subject to the project pathway and local approval requirements.
  • Procurement control: fiber count, strength-member designation and approved technical document must be confirmed before quotation or production approval.

Cable Construction

The following values are retained from BWNFiber local source record F0604. The record was previously flagged for complex multi-column alignment review. These entries therefore remain an offline working specification, not a released datasheet.

Component / parameterSource-recorded valueEvidence status
Fiber countTBC — source requiredNot stated in an explicit capacity field
Fiber colorsBlue, orange, green and brown; separate fibers, not ribbonDoes not independently establish orderable fiber count
Fiber typeG.657.A1Source record F0604
Strength memberΦ0.4 mm steel wire × 2 piecesSource record F0604; model-name conflict requires engineering review
Outer jacket materialLSZHSource record F0604
Outer jacket colorBlack or whiteSource record F0604; buyer must select one
Cable size2.0 ± 0.1 × 3.0 ± 0.1 mmSource record F0604

Optical Characteristics

These are source-recorded cable/fiber values. They are not a complete installed-link budget and do not include connector, splice, splitter or system margins.

Parameter / conditionSource-recorded valueRelease note
Mode field diameter at 1310 nm8.4–9.2 μmVerify against approved source table
Mode field diameter at 1550 nm9.3–10.3 μmVerify against approved source table
Cladding diameter125 ± 0.7 μmVerify against approved source table
Core concentricity error≤0.5 μmVerify against approved source table
Cladding non-circularity≤0.7%Verify against approved source table
Coating diameter245 ± 5 μmVerify against approved source table
Cable attenuation at 1310 nm≤0.4 dB/kmCable value; not insertion loss
Cable attenuation at 1550 nm≤0.3 dB/kmCable value; not insertion loss
Typical attenuation at 1310/1550 nm0.36/0.22 dB/kmDo not present as a guaranteed lot result without acceptance criteria
Maximum attenuation at 1310/1550 nm0.5/0.4 dB/kmConflicts with the separate cable attenuation row; engineering reconciliation required

Mechanical and Environmental Performance

Parameter / conditionSource-recorded valueRelease note
Installation temperature−30 to +70 °CVerify table alignment and test basis
Operating temperature−40 to +70 °CVerify table alignment and test basis
Storage temperature−40 to +70 °CVerify table alignment and test basis
Tensile load, long term60 NVerify test method and pass criteria
Tensile load, short term120 NVerify test method and pass criteria
Crush resistance, long term1000 N/100 mmVerify test method and pass criteria
Crush resistance, short term2200 N/100 mmVerify test method and pass criteria
Bend radius, dynamic30 × cable diameterFinished-cable limit; keep separate from G.657.A1 fiber design radius
Bend radius, static15 × cable diameterFinished-cable limit; keep separate from G.657.A1 fiber design radius

Interfaces and Connector Options

No connector, polish, pigtail, adapter or pre-terminated option is documented in the supplied product record. Treat this as a bare drop cable unless a separate assembly drawing is approved.

If the project requires field termination, identify the connector interface and confirm that the selected connector accepts the finished 2.0 × 3.0 mm cable profile. Do not infer SC/APC, SC/UPC or any other interface from the cable family name.

Fiber Type and Configuration Options

This draft covers only G.657.A1. G.657.A2, G.652.D and multimode fibers are different configurations and do not belong on this exact-model page unless an approved product record lists them.

The current ITU-T G.657 recommendation describes G.657.A1 as category-A bend-insensitive single-mode fiber and gives it a 10 mm minimum design radius at the fiber level. That standard-level statement does not replace the finished cable’s installation and service bend limits.

Compatibility and Application Conditions

Use the proposed configuration only after confirming all of the following:

  1. The route is an approved indoor FTTH subscriber pathway.
  2. The fiber count matches the network design and termination hardware.
  3. The cable entry, clamp, guide and termination hardware accept a 2.0 × 3.0 mm flat profile.
  4. The selected connector or splice method is documented for G.657.A1 fiber and the cable construction.
  5. The project authority accepts the supplied jacket and fire-performance evidence.
  6. Pulling, crushing, bending and temperature conditions stay within the approved finished-cable limits.

No compatible brand, terminal, ONU/ONT, connector or fast-connector model is asserted by this page.

How to Select the Correct Configuration

  1. Confirm the route. State whether the cable remains indoors for the complete run. Outdoor exposure, aerial spans, ducts, direct burial, water ingress or UV exposure require a different documented construction.
  2. Confirm the fiber count. Provide the active fibers and any approved reserve. Do not derive capacity from a generic color sequence.
  3. Resolve the strength-member designation. Ask BWNFiber to confirm whether this item is correctly named GJXFH with steel wires or should use a different model designation.
  4. Confirm the termination plan. State bare cable, fusion splice, field connector or factory-pre-terminated assembly, including interface and polish where applicable.
  5. Confirm the project rating. Provide the required flame, smoke, building-code or customer specification and request the matching evidence.
  6. Lock the delivery configuration. State total length, length per reel or roll, quantity, jacket color, marking, packaging and destination.

Difference from Related BWNFiber Pages

Page roleIntended ownershipBoundary
FTTH Drop Cable categoryBroad product discovery and selection among indoor, outdoor, aerial, duct and other drop-cable familiesShould own the broad keyword FTTH drop cable
GJXFH / GJXFJH / GJXFDH 1F/2F/4F page (P141)Family-level comparison of documented GJXFH/GJXFJH/GJXFDH optionsMust not duplicate this page’s exact confirmed configuration
GJXFH-4B6a1 page (P150)Exact-model technical validation and RFQ preparationMay remain independent only if fiber count, strength-member construction and source document are confirmed
GJXFH 1F and 2F pagesExact alternative counts/configurationsShould not be used to fill missing P150 facts

If engineering cannot prove a distinct GJXFH-4B6a1 configuration, merge the verified information into the appropriate family page instead of publishing another near-duplicate product URL.

Use Cases

  • Indoor FTTH subscriber drop routing.
  • Building endpoint runs where the approved pathway, termination hardware and cable limits match this exact configuration.

Outdoor, aerial, duct, direct-burial, rodent-resistant, waterproof and UV-resistant uses are not established by the supplied evidence.

Testing and Quality-Control Requirements

No product-specific test report, sampling plan, test equipment list or acceptance procedure was supplied with this draft. Before release or order approval, request:

  • The current approved datasheet and cross-sectional drawing.
  • Fiber-count and strength-member confirmation.
  • The applicable cable test methods and acceptance limits.
  • Lot- or reel-level attenuation records at the agreed wavelengths.
  • Measured reel length and cable marking record.
  • Mechanical and environmental test evidence where the purchase specification requires it.
  • Any declared flame, smoke or compliance report for the exact cable construction.

TBC — BWNFiber engineering and quality teams must identify which documents are standard deliverables and which require project-specific agreement.

Packaging and Procurement Information

Standard reel or roll length, packaging material, reel dimensions, gross weight, minimum order quantity, price, lead time and warranty are not documented in the supplied evidence. Provide these as quotation-specific commercial terms, not permanent page claims.

Required Information for an RFQ

Send the following in one controlled configuration request:

  • Product reference: GJXFH-4B6a1, subject to engineering confirmation.
  • Required fiber count.
  • Fiber grade: G.657.A1.
  • Cable profile: 2.0 ± 0.1 × 3.0 ± 0.1 mm.
  • Required strength-member material and the approved model designation.
  • Jacket material, color and required project/fire classification.
  • Installation route and indoor environmental conditions.
  • Bare cable or termination/connector requirement.
  • Total cable length and length per reel or roll.
  • Quantity, marking text and packaging requirement.
  • Destination country and delivery location.
  • Required datasheet, drawing, test records and compliance documents.

Datasheet, Drawing and Test-Report Area

DocumentCurrent statusRelease action
Product datasheetTBC — source requiredUpload only the current approved revision
Cross-sectional drawingTBC — source requiredMust identify fiber count and strength members
Optical test reportTBC — source requiredDefine lot/reel scope and acceptance values
Mechanical/environmental reportTBC — source requiredMatch the exact construction and test method
Compliance / flame reportTBC — source requiredDo not infer from the word LSZH
FAQ

Frequently Asked Questions

Is the fiber count confirmed for GJXFH-4B6a1?

No. The current record includes four fiber colors and a filename that refers to 4F, but it does not provide an explicit approved capacity field. BWNFiber must confirm the fiber count in a current datasheet or drawing before quotation or publication.

Is this a GJXFH or GJXH construction?

The local product record calls it GJXFH-4B6a1 and lists two steel-wire strength members. BWNFiber’s current FTTH Drop Cable category describes GJXFH as an FRP construction and GJXH as a steel-wire construction. Engineering must resolve the designation; this page must not choose one by inference.

What fiber grade is recorded?

The local record specifies G.657.A1 bend-insensitive single-mode fiber. Other fiber grades are separate configurations unless an approved source explicitly includes them.

What cable size is recorded?

The source record lists 2.0 ± 0.1 × 3.0 ± 0.1 mm. Match the finished profile to cable entries, clamps, guides and termination hardware.

Does LSZH prove a specific flame rating?

No. LSZH describes jacket material behavior in general terms; it does not by itself establish compliance with a particular building code, flame-spread test or smoke standard. Request evidence for the exact required classification.

Does this cable include connectors?

No connector or pre-terminated interface is documented. Treat it as bare cable unless an approved assembly drawing states otherwise.

What attenuation values are recorded?

The record lists cable attenuation of ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm. A second row lists different maximum values and must be reconciled before release. These figures are cable attenuation, not a complete link-loss budget.

Which bend radius should installers use?

Use the approved finished-cable limit, not the fiber-grade design radius. The current record lists 30D dynamic and 15D static, where D is the cable diameter, but those values still require source-table verification.

Is this cable approved for outdoor or aerial use?

Not from the evidence supplied. This record describes an indoor FTTH drop cable. Outdoor, aerial, duct, direct-burial, UV, water and messenger requirements need a separately documented construction.

What should be confirmed before a bulk order?

Confirm the model designation, fiber count, strength-member construction, jacket and project rating, termination plan, cable lengths, marking, packaging, test records, quantity, destination and commercial terms.

What should I send to BWNFiber for a quotation?

Send the proposed model, required fiber count, G.657.A1 grade, indoor route, cable profile, required strength member, jacket/color/rating, termination method, total and per-reel lengths, quantity, marking, documents and destination.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.