FTTH Drop Cable

GJXFH 1F G.657.A1 FRP LSZH FTTH Drop Fiber Optic Cable

GJXFH 1F G.657.A1 FRP LSZH FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

GJXFH

Buyer-oriented summary

This GJXFH configuration is defined as 1 fiber, ITU-T G.657.A1, parallel FRP strength members, an LSZH sheath, and a nominal cable profile recorded in the supplied BWNFiber draft as 1.95 ± 0.1 × 2.95 ± 0.1 mm. Release the configuration for quotation or production only after the exact part number, drawing revision, route suitability, mechanical limits, temperature ranges, and test requirements have been confirmed.

Configuration-control note: GJXFH is a family designation. Fiber count, fiber grade, reinforcement, sheath, dimensions, route, and ratings must match the same approved document set; do not combine values from different GJXFH variants.

Review disclaimer: Values shown here are provisional entries from the supplied V4 draft and are for reference only, not a guarantee. The approved BWNFiber datasheet, drawing, test limits, and quotation govern the final order.

Configuration lock

FieldProvisional value from supplied V4Public-release status
BWNFiber part numberTBC — source requiredBlocked
Product familyGJXFHRequires product-owner confirmation
Fiber count1FRequires source-row confirmation
Fiber gradeITU-T G.657.A1Requires source-row confirmation
Strength memberFRP, recorded as 0.5 mmRequires drawing confirmation, including quantity and position
Sheath materialLSZHMaterial only; no fire class or certification is established
Sheath colorBlackRequires drawing/datasheet confirmation
Cable profile1.95 ± 0.1 × 2.95 ± 0.1 mmRequires drawing confirmation
Cable mass9.5 ± 2 kg/kmRequires approved datasheet
Intended routeTBC — source requiredBlocked
Standard reel/roll lengthTBC — source requiredBlocked
MarkingTBC — source requiredBlocked

Optical, mechanical, and environmental data

do not use for order release a final table until BWNFiber supplies the original worksheet and engineering resolves its ambiguous or missing units. In particular:

  • ITU-T G.657 uses nm for the measurement wavelength and µm for mode-field diameter. The V4 note says the source sheet labels MFD with nm; that discrepancy must be corrected in the source or formally explained, not silently rewritten.
  • PMD values in V4 are missing units. Do not infer units from a competitor page. The exact source row and approved product specification must govern.
  • V4’s attenuation, bend, tensile, crush, and temperature values remain provisional until the source worksheet and test basis are reviewed.
  • Fiber-standard properties do not replace finished-cable test values, and cable values do not represent complete installed-link loss including splices and connectors.

How to confirm this configuration

  1. Identify the BWNFiber part number and drawing revision.
  2. Confirm the complete route: indoor, protected transition, outdoor wall, duct, or aerial sections.
  3. Lock 1F, G.657.A1, FRP construction, LSZH sheath, color, and dimensions to one approved document set.
  4. Confirm the applicable installation, operation, storage, and transport limits.
  5. State the required tensile, crush, bend, optical, and environmental test methods and acceptance limits.
  6. Approve cable marking, length per reel or roll, quantity, packing, and delivery destination.
  7. Define the required submittal package: datasheet, drawing, sample, material declaration, test report, and traceability records.

When not to release this configuration

Do not release it when the route includes unverified outdoor exposure, aerial self-support, armor, UV, water-blocking, rodent protection, or a named fire-performance class. Select another documented model or request an engineering review when any of these conditions applies.

Required information for an RFQ

Send BWNFiber:

  • project name and destination market;
  • route drawing and indoor/outdoor transitions;
  • required part number or reference cable;
  • 1F G.657.A1 confirmation;
  • FRP construction and exact cable dimensions;
  • sheath material, color, and required fire/smoke documentation;
  • total quantity and length per reel or roll;
  • cable marking and packing requirements;
  • installation, operating, storage, and transport conditions;
  • required test methods, acceptance limits, sample plan, and documents;
  • delivery destination and requested schedule.

CTA

Request the exact GJXFH 1F datasheet, drawing, and configuration review. Include the route, quantity, length schedule, project documentation requirements, and delivery destination so BWNFiber can confirm whether this configuration matches the application before quotation.

Related BWNFiber resources

Download area

DocumentStatus
Product datasheetTBC — source required
Cross-section drawingTBC — source required
Optical/mechanical test reportTBC — source required
Material or fire-performance declarationTBC — source required
Packing and marking specificationTBC — source required
FAQ

FAQ and PAA-Style Question Bank

Only publish answers whose required evidence is closed. These are buyer-question candidates, not verified Google PAA exports.

  1. What does GJXFH identify?
    It identifies a cable family, not every order parameter. Confirm the exact fiber count, grade, strength members, sheath, dimensions, route, and ratings from the same approved BWNFiber document set.

  2. Is this GJXFH cable 1 fiber or 2 fibers?
    This proposed configuration is recorded as 1F in the supplied V4. Confirm it against the original source row and released datasheet before publication or order release.

  3. Is G.657.A1 compatible with the project network?
    G.657.A1 is an ITU-T bend-loss-insensitive single-mode fiber category, but the project designer must approve the grade against the installed network, bend conditions, wavelength plan, and acceptance specification.

  4. Does FRP make this cable self-supporting?
    Not by itself. A strength-member material does not establish aerial self-support, span, hardware, or load rating. Those conditions require model-specific evidence.

  5. Does an LSZH sheath prove a fire rating?
    No. LSZH describes material behavior; a named fire class or code compliance requires the applicable declaration or test evidence for the exact construction.

  6. Can this cable be installed outdoors?
    TBC — source required. Do not approve outdoor, UV, moisture, duct, wall, or aerial exposure from the generic GJXFH name.

  7. What bend radius applies to this cable?
    TBC — source required. The finished-cable static/service and dynamic/installation limits must come from the approved datasheet and must not be replaced with a bare-fiber macro-bend value.

  8. What attenuation applies at 1310 and 1550 nm?
    V4 records provisional maximum values, but the original worksheet and units must be reviewed before release. These values would describe the cable/fiber, not the full installed link with connectors and splices.

  9. What documents should be requested before a bulk order?
    Request the approved datasheet, drawing, source-controlled specification, material declarations required by the project, test methods and limits, sample approval record, packing/marking specification, and lot/reel traceability plan.

  10. What information should be included in a GJXFH quotation request?
    Include route, destination market, fiber count and grade, construction, dimensions, sheath requirements, total quantity, length schedule, marking, packing, test/document requirements, and delivery destination.

  11. How is this configuration different from the broader Butterfly Flat FTTH Drop Cable family?
    It is a proposed exact 1F/G.657.A1/FRP/LSZH configuration. The family page includes multiple counts, strength systems, and dimensions, so its values are not automatically interchangeable with this variant.

  12. Should this configuration have a separate product URL?
    Not with the current evidence. It should remain a variant section until it has a unique orderable identity, approved evidence, and a distinct commercial role supported by query and conversion data.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.