Indoor Fiber Cable

GJPFJV 4F G.657.A1 5.5mm LSZH Distribution Fiber Optic Cable

GJPFJV 4F G.657.A1 5.5mm LSZH Distribution Fiber Optic Cable for indoor building or equipment-room routes at 4F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

GJPFJV

Configuration at a Glance

FieldSupplied configurationApproval note
Fiber count4FThis row applies only to the four-fiber configuration.
Fiber gradeG.657.A1Confirm against the approved BWNFiber datasheet.
Buffer constructionTight buffer, 0.9 ± 0.05 mmSource approval required.
Strength memberAramid yarn (source wording: Kevlar yarn)Confirm the approved material wording.
Outer sheathFR LSZH-UV, ivoryMaterial/rating evidence required for the target project.
Outside diameter5.5 ± 0.2 mmUse the approved OD for pathway and hardware checks.

Optical Characteristics

ParameterSupplied valueApproval status
Attenuation at 1310 nm≤0.4 dB/kmConfirm on the approved datasheet or test record.
Attenuation at 1550 nm≤0.3 dB/kmConfirm on the approved datasheet or test record.

Additional optical fields in the working source remain withheld from public copy until BWNFiber resolves the MFD and PMD units and approves the original source mapping.

Mechanical and Environmental Limits

ConditionSupplied limitApproval note
Minimum bend radius, long term10DConfirm that D is the approved finished-cable outside diameter.
Minimum bend radius, short term20DApply the installation condition separately from the long-term condition.
Tensile load, long term100 NDo not exceed the approved condition.
Tensile load, short term300 NConfirm the pulling method and approved cable record.
Crush load, long term100 N/100 mmKeep the length basis with the value.
Crush load, short term500 N/100 mmKeep the length basis with the value.
Installation temperature-10 to +60 °CApply during installation only.
Operation and transport temperature-20 to +70 °CConfirm whether a separate storage range is required.

Selection and Approval Boundary

Use this four-fiber row only when the required cable count, fiber grade, construction and pathway match the project. G.657.A1 identifies the optical fiber grade; it does not replace the finished cable’s bend, pull, crush, jacket or building-rating requirements.

Before approving the configuration, confirm:

  • the controlled part number and drawing revision;
  • the indoor pathway, building zone and any indoor/outdoor transition;
  • the exact fire, smoke, halogen or other project rating and its test evidence;
  • the termination or splice method and compatible hardware;
  • the outside diameter, bend radius, pulling and crush limits;
  • the ordered length, length per drum or roll, quantity and cable marking;
  • the packaging plan, delivery destination and required approval documents.

Product Illustration

Use the existing supplied file only after rights and configuration review:

  • File: Distribution Tight Buffer Optical Cable 4F G657A1 OD:5.5.webp
  • Alt: Cross-section diagram of 4-fiber tight-buffered distribution cable with outer sheath and aramid yarn
  • Caption: Illustrative cross-section of the supplied 4F tight-buffered construction; dimensions and materials must be verified against the approved drawing.

The image is an illustrative, watermarked cross-section. It is not a test record, production photo or dimensional drawing.

Configuration Questions

Does this row apply to other fiber counts?

No. The values above are scoped to the supplied 4F configuration. Other counts require their own approved configuration rows.

Does G.657.A1 determine the finished cable bend radius?

No. G.657.A1 identifies the fiber grade. The finished cable’s approved long-term and installation bend limits still govern cable handling.

Does the LSZH description prove a North American building rating?

No. A material description does not establish an OFNR, OFNP, plenum, riser or other project rating. State the required rating in the RFQ and request evidence for the exact cable configuration.

What optical values are available for initial review?

The supplied record lists attenuation of ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm. These values still require confirmation on an approved BWNFiber datasheet or test record and are not a complete installed-link loss budget.

What should be included in the quotation request?

Identify the 4F G.657.A1, 5.5 mm nominal tight-buffered configuration and send the pathway, required project rating, total length, length per drum or roll, quantity, cable marking, termination plan, required documents and delivery destination.

Request a GJFJV Configuration Review

Send the cable schedule or pathway requirement together with the fields above. BWNFiber should return the controlled part number, approved datasheet/drawing, evidence status and quotation for the reviewed configuration. Availability, MOQ, lead time, packing length and compliance remain TBC — source required until confirmed in the quotation.

Related BWNFiber Resources

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.