Indoor Fiber Cable

GJFJV 2F Riser Duplex Indoor Fiber Optic Cable

GJFJV 2F Riser Duplex Indoor Fiber Optic Cable for indoor building or equipment-room routes at 2F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

GJFJV

GJFJV 2F Riser Duplex Cable at a Glance

This page covers one 2-fiber duplex GJFJV indoor cable configuration identified in the supplied BWNFiber record as Riser. The record lists three cable-size and tensile combinations and a choice of single-mode or multimode fiber grades. Select one fiber grade and one complete size/mechanical row for the quotation; do not combine values from different alternatives.

Approval note: “Riser” is the source designation, not proof of a specific North American fire rating. Jacket material, exact listing or certification, test method, report number and acceptance for the intended building route are TBC: source required.

Technical disclaimer: Values in this offline draft reproduce a supplied record that still requires BWNFiber engineering approval. They are configuration-specific reference values, not a guarantee or a substitute for the approved datasheet, drawing, quotation and project-required rating evidence.

Key Configuration Facts

  • Fiber count: 2F
  • Cable format: Duplex, as named in the supplied P127 record
  • Fiber options: SM G.652; G.652.D / SMF-28 designation; SM G.657.A2; OM1 62.5/125; OM2 50/125; OM3 50/125; OM4 50/125
  • Strength member: Aramid yarn
  • Source jacket designation: Riser
  • Cable-size options: 1.6 × 3.4 mm, 2.0 × 4.0 mm or 2.8 × 6.0 mm
  • Standard reel length: 2 km

The precise construction drawing, buffer diameter, jacket compound, jacket color, flame-rating evidence, cable marking and connector/termination condition remain TBC: source required.

Technical Specifications

Construction and Mechanical Options

Select one cable-size rowLong-term tensile loadShort-term tensile loadFiber countStrength memberStatus
1.6 × 3.4 mm80 N160 N2FAramid yarnSupplied P127 record; confirm drawing and tolerances
2.0 × 4.0 mm120 N200 N2FAramid yarnSupplied P127 record; confirm drawing and tolerances
2.8 × 6.0 mm160 N300 N2FAramid yarnSupplied P127 record; confirm drawing and tolerances

Do not approve the cable from the model name alone. The selected dimensions and tensile limits must remain attached to the same row in the quotation, drawing and purchase order.

Optical Characteristics Listed in the Supplied Record

Select one fiber optionWavelengthMaximum attenuation listed in sourceVerification status
SM G.6521310 / 1550 nm0.36 / 0.22 dB/kmEngineering sign-off required
G.652.D / SMF-28 designation1310 / 1550 nm0.36 / 0.22 dB/kmExact fiber brand and designation TBC
SM G.657.A21310 / 1383 / 1550 nm0.36 / 0.36 / 0.22 dB/kmEngineering sign-off required
OM1 62.5/125850 / 1300 nm3.0 / 1.0 dB/kmEngineering sign-off required
OM2 50/125850 / 1300 nm3.0 / 1.0 dB/kmEngineering sign-off required
OM3 50/125850 / 1300 nm3.0 / 1.0 dB/kmEngineering sign-off required
OM4 50/125850 / 1300 nm3.0 / 1.0 dB/kmEngineering sign-off required

These are alternative fiber grades, not characteristics that apply simultaneously to one cable. The final datasheet and quotation should name the selected grade exactly and identify the applicable test method.

Handling and Environmental Limits Listed in the Supplied Record

ParameterSource-listed valueApproval note
Minimum bend radiusDynamic 20D; static 10DConfirm what dimension D represents in the approved drawing
Installation temperature−20°C to +70°CEngineering sign-off required
Storage temperature−20°C to +70°CEngineering sign-off required
Operation and transport temperature−20°C to +70°CEngineering sign-off required

The source record contains a crush entry with an incomplete unit (N/100 without a length unit). It is intentionally excluded from this draft and must not be restored until BWNFiber engineering supplies the complete unit and test method.

Interfaces and Termination

The supplied record does not identify connector type, polish, terminated length, breakout length or factory termination. Treat this page as a bulk-cable configuration unless the approved drawing says otherwise.

  • Connector or interface: TBC: source required
  • Factory-terminated or unterminated supply: TBC: source required
  • Tight-buffer diameter and color code: TBC: source required
  • Compatible panels, fan-out parts or termination hardware: TBC: source required

How to Select the Correct Configuration

  1. Confirm the route. State the building area, vertical or horizontal path, tray or conduit, and any transition to an outdoor or entrance segment.
  2. Confirm the required rating. Provide the project specification and authority-required fire, smoke or halogen evidence. Do not use the word “Riser” as a substitute for a test report or listing.
  3. Select one fiber grade. Choose G.652, G.652.D/approved equivalent, G.657.A2, OM1, OM2, OM3 or OM4 according to the optical design and equipment requirements.
  4. Select one cable-size row. Keep its long- and short-term tensile limits together.
  5. Confirm handling limits. Put the approved bend-radius and temperature limits on the installation documentation.
  6. Fix the reel plan. State total length, length per reel, number of reels, marking and destination.
  7. Approve the documents. Review the current datasheet, construction drawing, rating evidence and any required test records before the purchase order.

Differences From Related BWNFiber Pages

Page or product roleWhat it should ownWhat this page should not target
Indoor Fiber Cable categoryBrowse and compare indoor cable families, structures and selection criteriaThe exact P127 specification table
Existing GJFJV Indoor Fiber Optic Cable pageGJFJV family overview and routing to validated variantsEvery exact variant’s full specification table if separate SKU pages are approved
1F simplex GJFJV variantsSingle-fiber/simplex configurations2F duplex configuration intent
2F LSZH or plenum variantsTheir verified jacket/rating configurationThe P127 Riser-designated configuration
This P127 pageExact 2F duplex configuration, selectable fiber grade, size/tensile row and RFQ inputsBroad “indoor fiber cable” or generic “GJFJV cable” selection intent

Suitable Use and Compatibility Boundaries

The supplied record supports an indoor distribution application. Final suitability depends on the approved route, construction, rating evidence, termination method and local project requirements.

  • Indoor distribution: supported at application-name level by the supplied record.
  • Building riser use: TBC: exact rating/listing and authority acceptance required.
  • Outdoor, wet, UV-exposed, direct-burial or armored use: not established by the supplied record.
  • Transmission reach or Ethernet application: not stated; determine from the selected fiber, equipment and link design.
  • Compatibility with a named connector, panel, brand or active device: TBC: source required.

Testing and Quality-Control Documents to Request

The supplied record does not prove a production test method or delivered test report. For technical approval, ask BWNFiber to identify which of the following are available for the selected configuration:

  • Current product datasheet and cross-section drawing
  • Fiber manufacturer and exact grade declaration
  • Dimensional and mechanical test method
  • Attenuation test method and factory result format
  • Complete crush test unit, method and limit
  • Riser/fire-rating test standard, report, listing and covered construction
  • Reel-length tolerance and cable-marking sample
  • Inspection or test record supplied with the order

All items above are TBC: BWNFiber confirmation required unless attached to the quotation.

Packaging and Procurement Information

The supplied record lists a 2 km standard reel length. Reel material, allowable length tolerance, minimum order quantity, shorter cut lengths, packaging method, lead time, price, stock and warranty are TBC: commercial confirmation required.

Information Required for an RFQ

Send one complete configuration rather than a list of interchangeable options:

  • Product: GJFJV 2F Riser Duplex Indoor Fiber Optic Cable
  • Selected fiber grade
  • Selected cable-size/tensile row
  • Required project rating and supporting-document requirement
  • Route and installation conditions
  • Total cable length
  • Length per reel and number of reels
  • Jacket color and cable marking
  • Required drawing, datasheet and test records
  • Quantity, delivery destination and requested delivery date

CTA: Send BWNFiber the route, selected fiber grade, cable-size row, reel schedule and required rating evidence for a configuration review and quotation.

Datasheet, Drawing and Test-Report Area

  • Product datasheet: TBC: approved file required
  • Construction drawing: TBC: approved file required
  • Riser/fire-rating evidence: TBC: exact construction and report required
  • Factory test-report template: TBC: approved file required

Related Resources

FAQ

Frequently Asked Questions

What does 2F mean on this page?

It identifies a two-fiber cable configuration. The supplied record describes the product as duplex. The final drawing should confirm the cross-section and how the two fiber units are arranged.

Is “Riser” the same as a verified OFNR rating?

Not on the evidence currently available. “Riser” is the source designation. A North American project should request the exact listing or test standard, report, covered construction and acceptance requirement before approval.

Which fiber grades are available?

The supplied record lists SM G.652, a G.652.D/SMF-28 designation, SM G.657.A2, OM1, OM2, OM3 and OM4. Choose one grade for the order; do not combine their optical values.

How should I choose the cable size?

Choose one complete row: 1.6 × 3.4 mm with 80/160 N, 2.0 × 4.0 mm with 120/200 N, or 2.8 × 6.0 mm with 160/300 N for long-/short-term tensile load. Confirm dimensional tolerances in the approved drawing.

What bend-radius limit applies?

The supplied record lists dynamic 20D and static 10D. BWNFiber should confirm the definition of D and place the approved value on the product drawing and installation instructions.

Why is no crush rating shown?

The source unit is incomplete, so publishing the value could mislead engineering approval. The complete unit, test method and limit must be confirmed before it can be added.

Does this cable include connectors?

The supplied record does not specify connectors or termination. Confirm whether the quotation is for bulk unterminated cable or a factory-terminated assembly.

What reel length is listed?

The supplied record lists 2 km as the standard reel length. Confirm reel tolerance, alternative cut lengths, reel material and packaging in the quotation.

Can this cable be used outdoors?

Outdoor, wet, UV-exposed, direct-burial or armored use is not established by the supplied record. Use a model documented for those conditions or define an approved transition at the building entrance.

What should be attached to the purchase approval?

Attach the approved datasheet, cross-section drawing, selected fiber and size row, rating evidence, cable-marking sample, reel plan and any required factory test-record format.


Related Products