GJFJV
GJFJV 2-48F Tight-Buffered LSZH Distribution Fiber Optic Cable
GJFJV 2-48F Tight-Buffered LSZH Distribution Fiber Optic Cable for indoor building or equipment-room routes at 2-48F. Confirm jacket and fiber grade before quoting.

Product Value Summary
The supplied BWNFiber record describes a multi-fiber, tight-buffered indoor distribution cable family covering 2, 4, 6, 8, 12, 16, 24, 36 and 48 fibers. It records aramid yarn as the strength member and lists single-mode G.652.D, multimode 50/125 and multimode 62.5/125 optical options. Select a fiber-count row first; outside diameter, tight-buffer diameter, weight field and mechanical limits differ by count.
Before quotation or release: confirm the model designation, jacket material and required project fire/smoke/halogen rating as separate fields. An LSZH material label alone does not prove a specific building-code or flame-test classification.
Short Answer for Buyers
Use this GJFJV family when the approved BWNFiber datasheet confirms that its tight-buffered construction, fiber count, diameter, pulling/crush limits and jacket evidence match the indoor pathway. Do not select from the family name alone. Send the route, required fiber grade and count, termination plan, project rating, exact lengths and quantity for configuration review.
Key Features Recorded in the Supplied BWNFiber File
- Fiber counts: 2F, 4F, 6F, 8F, 12F, 16F, 24F, 36F and 48F.
- Fiber options: SM G.652.D, MM 50/125 and MM 62.5/125.
- Construction: tight-buffered fibers with aramid-yarn strength member.
- Jacket: recorded as LSZH; exact designation and rating evidence require confirmation.
- Count-specific data: outside diameter, tight-buffer diameter, weight field, tensile limit, crush limit and bend radius are listed by row.
- Standard packing length: supplied record states 2 km; reel/length availability requires order confirmation.
Construction and Evidence Status
| Component / parameter | Supplied record | Release status |
|---|---|---|
| Product family | GJFJV | TBC — confirm designation against jacket convention |
| Fiber count | 2–48F in nine listed configurations | Supplied BWNFiber record; engineering approval required |
| Fiber type | SM G.652.D / MM 50/125 / MM 62.5/125 | Supplied BWNFiber record; confirm exact grade nomenclature per order |
| Buffer construction | Tight buffered | Supplied BWNFiber record |
| Strength member | Aramid yarn | Supplied BWNFiber record |
| Jacket | LSZH | TBC — confirm material, model code and exact test/rating evidence |
| Armor / water blocking / UV suitability | Not stated | TBC — do not infer |
| Connector or termination interface | Not stated; bulk-cable page | TBC — define splice, fan-out or termination plan |
Count-Specific Mechanical Selection Table
Engineering review required. Values below are transcribed from the supplied P128 V4 file. The source column is labeled
Weight (KG)without a per-length basis, and the mechanical table usesminimum allowableterminology. Confirm units, test conditions and whether limits are minimum requirements or maximum permissible installation loads before publication.
| Fiber count | Outside diameter (mm) | Tight-buffer diameter (mm) | Source weight field (KG; basis TBC) | Tensile short / long term (N) | Crush short / long term (N/100 mm) | Bend radius short / long term |
|---|---|---|---|---|---|---|
| 2F | 2.9 ± 0.1 | 0.6 ± 0.05 | 8 | 220 / 70 | 350 / 200 | 20D / 10D |
| 4F | 5.0 ± 0.1 | 0.9 ± 0.05 | 14.5 | 220 / 70 | 350 / 200 | 20D / 10D |
| 6F | 5.2 ± 0.1 | 0.9 ± 0.05 | 17 | 440 / 130 | 1000 / 200 | 20D / 10D |
| 8F | 5.6 ± 0.2 | 0.9 ± 0.05 | 26.5 | 440 / 130 | 1000 / 200 | 20D / 10D |
| 12F | 6.3 ± 0.2 | 0.9 ± 0.05 | 31 | 440 / 130 | 1000 / 200 | 20D / 10D |
| 16F | 7.2 ± 0.2 | 0.9 ± 0.05 | 45.5 | 660 / 200 | 1000 / 200 | 20D / 10D |
| 24F | 8.3 ± 0.3 | 0.9 ± 0.05 | 62 | 660 / 200 | 1000 / 200 | 20D / 10D |
| 36F | 9.5 ± 0.3 | 0.9 ± 0.05 | 80 | 660 / 200 | 1000 / 200 | 20D / 10D |
| 48F | 10.5 ± 0.3 | 0.9 ± 0.05 | 101.2 | 660 / 200 | 1000 / 200 | 20D / 10D |
D means the finished cable outside diameter for the selected row. Confirm the handling method and applicable test procedure in the approved datasheet before converting these ratios into site instructions.
Optical Characteristics Recorded in the Supplied File
These are product-record values, not a complete link-loss budget. Connector, splice and system allowances are outside this table. Engineering must verify the full source optical matrix and its units before release.
| Fiber option | Wavelength (nm) | Recorded attenuation (dB/km) | Status |
|---|---|---|---|
| SM G.652.D | 1310 / 1550 | ≤0.36 / 0.23 | Source-recorded; approval required |
| MM 50/125 | 850 / 1300 | ≤3.0 / 1.0 | Source-recorded; exact grade/standard TBC |
| MM 62.5/125 | 850 / 1300 | ≤3.0 / 1.0 | Source-recorded; exact grade/standard TBC |
The V4 trace flags unresolved unit/condition rows for zero-dispersion slope, PMD and numerical aperture. They are intentionally excluded from this public-facing draft until the complete source matrix is approved.
Storage and Packing
| Parameter | Supplied record | Release status |
|---|---|---|
| Storage temperature | Source shows -40+60 °C | TBC — confirm that this means −40 °C to +60 °C and confirm the applicable condition |
| Standard drum length | 2 km | Confirm availability, tolerance and reel plan per order |
| Marking, reel ID and packaging | Not specified | TBC — define in quotation and purchase documents |
Interfaces and Connector Options
No connector, polish, pinning, polarity or pre-terminated end condition is specified in the supplied record. Treat this as bulk indoor distribution cable unless an approved drawing states otherwise. Define whether fibers will be spliced, faned out or connectorized, and confirm the panel, tray, gland, entry-port and bend-management interfaces before order release.
Compatibility and Application Conditions
This family can be evaluated for indoor building pathways, equipment rooms and distribution routes only after the exact model record confirms the installation environment. The supplied file does not establish outdoor, UV, wet-location, plenum, riser, rodent-resistant or armored suitability.
Check these project conditions:
- Indoor route and any indoor/outdoor transition.
- Tray, conduit, riser or cabinet pathway and available diameter.
- Fiber mode, grade and count, including reserve fibers.
- Splice, fan-out or direct-termination method.
- Pulling, crush and bend conditions for the selected count.
- Required fire, smoke, halogen and building approval evidence.
- Panel, splice-tray, gland and entry-port capacity.
How to Select the Correct Configuration
- Fix the route. Mark every room, riser, tray, conduit, cabinet and transition point.
- Choose one fiber option. Do not combine single-mode and multimode table values in one order line.
- Choose the fiber count. Match active links, duplex pairs, redundancy and spare capacity to the panel and tray plan.
- Use the matching row. Keep outside diameter and mechanical values with the selected count.
- Confirm the jacket evidence. State the material and exact project-required test or rating; do not approve from
LSZHalone. - Define termination. State splice, fan-out, connectorization and compatible hardware requirements.
- Close the reel plan. Confirm total length, length per reel, quantity, marking, destination and approval documents.
Differences From Related BWNFiber Indoor Cable Pages
| Page / family | Distinct role | Do not merge its exact claims into this page |
|---|---|---|
| GJFJV 2F LSZH Duplex Indoor Cable (P125) | Fixed two-fiber duplex geometry with separate cable-size choices | Its fiber-grade list, rectangular dimensions and temperature claims |
| GJFJV 1F G.657.B3 3.0 mm TPU Cable (P121) | Fixed single-fiber, G.657.B3, TPU and 3.0 mm configuration | TPU, G.657.B3 and 1F-specific mechanics |
| GJPFJV 4F G.657.A1 5.5 mm Cable (P109) | Fixed 4F, G.657.A1, 5.5 mm and FR LSZH-UV record | GJPFJV naming, UV claim and its optical matrix |
| 24–144F Multi-Purpose Distribution Cable (P135) | Higher-count subunit construction with FRP central member | FRP central member, PVC option and 72F–144F data |
| Indoor Fiber Cable category | Broad selection intent across distribution, zipcord, breakout and micro-bundle families | Category-wide comparison and general education |
Testing and Quality-Control Requirements
The supplied record does not provide an approved BWNFiber test procedure or test-report sample. Before publication or purchase approval, request and verify:
- selected fiber grade and attenuation limits by wavelength;
- finished outside diameter and tight-buffer diameter;
- tensile, crush and bend test method plus acceptance limits;
- length measurement and reel identification;
- jacket material declaration and required project test/rating evidence;
- construction drawing and approved datasheet revision.
Do not claim OTDR, insertion-loss/return-loss or third-party certification results unless the exact test document and configuration are available.
Required Information for an RFQ
Send the following in one configuration line or attached cable schedule:
- Product family: GJFJV, subject to designation confirmation.
- Indoor route and pathway type.
- Fiber grade and fiber count.
- Required jacket material and exact project rating/test evidence.
- Selected count-specific outside diameter and mechanical limits.
- Termination or splice plan and compatible hardware.
- Total cable length, length per reel, quantity and cable marking.
- Delivery country and destination.
- Required datasheet, drawing, material declaration and test records.
Primary CTA: Request a GJFJV configuration and evidence review.
Secondary CTA: Send a cable schedule or pathway drawing for model matching.
Downloads — Source Required
| Asset | Status |
|---|---|
| Approved product datasheet | TBC — source required |
| Construction drawing | TBC — source required |
| Jacket/material declaration | TBC — source required |
| Mechanical test method/report | TBC — source required |
| Optical test record example | TBC — source required |
Frequently Asked Questions
What fiber counts are recorded for this GJFJV cable family?
The supplied BWNFiber record lists 2, 4, 6, 8, 12, 16, 24, 36 and 48 fibers. Each count has its own outside diameter and weight field; tensile values also change by count group. Select one complete row for engineering and quotation review.
Is every 2–48F configuration the same outside diameter?
No. The supplied outside diameters run from 2.9 ± 0.1 mm for 2F to 10.5 ± 0.3 mm for 48F. Confirm the exact row against conduit, gland, clamp and panel-entry space.
Does LSZH automatically prove the cable meets a fire code?
No. LSZH describes material behavior; it does not by itself prove a specific flame-spread, smoke-density, acidity or building-code classification. Request evidence for the exact cable configuration and have the project authority confirm acceptance.
Why must the GJFJV model designation be confirmed?
The supplied P128 record pairs GJFJV with an LSZH jacket, while BWNFiber’s current category explanation associates V with PVC and H with an LSZH variant. Engineering must resolve this conflict before the title, datasheet or order code is released.
Which fiber types are listed?
The supplied record lists SM G.652.D, MM 50/125 and MM 62.5/125. The exact multimode grade and applicable standard are not stated, so confirm them in the approved datasheet and purchase specification.
Can the attenuation table be used as a link budget?
No. The table contains source-recorded cable/fiber attenuation by wavelength. A link budget also needs connector, splice, margin and equipment assumptions for the actual route.
What does 20D/10D mean in the bend-radius field?
D is the finished outside diameter of the selected cable row. The supplied table records 20D short term and 10D long term. Confirm the test method and installation instructions before using these ratios on site.
Is this cable approved for outdoor installation?
Not from the supplied evidence. Outdoor, UV, moisture and water-blocking suitability are not established. Use an outdoor-rated model or an approved transition plan unless the exact product documentation covers the complete route.
How should I choose between distribution and breakout cable?
Start with the termination and protection plan. Distribution cable groups tight-buffered fibers under a common jacket; breakout designs give individual subunits more protection and different termination handling. Compare the exact construction, pathway space, panel plan and approved datasheets.
What should be confirmed before a quotation?
Confirm the route, fiber grade and count, model designation, jacket and required rating evidence, outside diameter, mechanical limits, termination method, lengths per reel, quantity, marking and destination.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.