Indoor Fiber Cable

GJFJV 1F Riser Simplex Indoor Fiber Optic Cable

GJFJV 1F Riser Simplex Indoor Fiber Optic Cable for indoor building or equipment-room routes at 1F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

GJFJV

Product value summary

The BWNFiber GJFJV 1F Riser Simplex Indoor Fiber Optic Cable record covers one fiber in a simplex, tight-buffered indoor construction with aramid yarn. The supplied record lists 1.6 mm, 2 mm and 3 mm cable-size options and six alternative fiber grades. It is intended for buyers who need to keep the selected fiber grade, diameter, tensile values, bend limit and reel plan in one quotation record.

Choose one fiber grade and one cable-size row. The alternatives do not all describe one finished cable.

Configuration boundary

This page is limited to the supplied 1F simplex / RISER-designated configuration. It does not cover a 2F duplex cable, an LSZH-only configuration, a plenum configuration, a finished connectorized patch cord or an outdoor cable.

For a US building project, do not approve the cable from the word RISER alone. The authority having jurisdiction and the project specification determine the required rating. Ask for model-level marking and test/listing evidence before substituting this configuration for an OFNR-, UL 1666-, NEC-, FT4- or other specified cable.

Technical specifications

ParameterSupplied BWNFiber record
Product modelGJFJV
Fiber count1F
Cable formSimplex indoor fiber optic cable
Fiber optionsSM G652; SM G.657.A2; OM1 62.5/125; OM2 50/125; OM3 50/125; OM4 50/125
Configuration labelRISER
Strength memberAramid yarn
Cable-size options1.6 mm; 2 mm; 3 mm
Minimum bend radiusDynamic 20D / static 10D
Installation temperature−20°C to +70°C
Storage temperature−20°C to +70°C
Operation and transport temperature−20°C to +70°C
Standard reel length2 km

D refers to the selected finished cable diameter. The V4 record contains an unresolved crush source unit (N/100 without a length unit), so no crush rating is stated on this draft.

Cable-size and tensile options

Keep each diameter and its mechanical values in the same row.

Cable sizeLong-term tensileShort-term tensile
1.6 mm40 N80 N
2 mm60 N100 N
3 mm80 N150 N

Optical characteristics

Fiber optionWavelengthAttenuation in the supplied record
SM G6521310 / 1383 / 1550 nm0.32 / 0.32 / 0.18 dB/km
SM G.657.A21310 / 1383 / 1550 nm0.35 / 0.35 / 0.21 dB/km
OM1 62.5/125850 / 1300 nm2.7 / 0.6 dB/km
OM2 50/125850 / 1300 nm2.3 / 0.6 dB/km
OM3 50/125850 / 1300 nm2.4 / 0.6 dB/km
OM4 50/125850 / 1300 nm2.4 / 0.6 dB/km

These rows are alternative fiber selections. Confirm the current signed datasheet and the project link requirements before using any value for design or acceptance.

Riser approval boundary for US projects

Competitor product pages commonly publish a precise rating and supporting standard or listing. This BWNFiber source record does not yet provide equivalent model-level evidence. Before approval, request:

  1. The current signed datasheet for the selected diameter and fiber grade.
  2. A cable construction drawing and the exact jacket/material declaration.
  3. The cable-print legend and model/part-number mapping.
  4. The required flame-spread or listing evidence for the exact model.
  5. Confirmation of the bend, tensile, temperature and optical values used in the purchase specification.

Until those documents are approved, describe the item as a RISER-designated configuration under review, not as certified OFNR or compliant with a named US standard.

How to select the correct configuration

  1. Confirm that the route is indoor and define the building zone, pathway and local code requirement.
  2. Select one fiber grade: SM G652, SM G.657.A2, OM1, OM2, OM3 or OM4.
  3. Select one cable diameter: 1.6 mm, 2 mm or 3 mm, keeping its tensile values from the same row.
  4. Check the dynamic 20D and static 10D bend limits against the selected diameter and route.
  5. Confirm the required rating evidence, cable marking, termination method and approval documents.
  6. Fix total length, reel plan, quantity and destination before quotation.

Related-configuration differences

RequirementCorrect page/configuration role
One fiber, simplex, RISER-designatedThis P124 draft
One fiber with LSZH as the differentiating jacket labelSeparate 1F LSZH configuration
One fiber with a plenum designationSeparate 1F plenum configuration
Two fibers in a duplex formSeparate 2F duplex configuration
Broad indoor cable family comparisonIndoor Fiber Cable category page

These labels are not interchangeable. Each related configuration requires its own current technical and rating evidence.

Applications and compatibility conditions

The supplied record supports an indoor-cable product role. Exact building-zone approval, connectorization, panel compatibility, outdoor exposure, UV resistance, water blocking and fire-rating suitability are TBC — source required. Do not infer them from the GJFJV family name.

Testing and quality-control evidence

The following public claims are not supported by the supplied V4 record and must remain withheld until BWNFiber provides source documents:

  • Model-level flame/riser test or listing result: TBC — source required
  • Finished-cable inspection or test plan: TBC — source required
  • Optical test method and release limits: TBC — source required
  • Batch test report format or sample report: TBC — source required
  • Certification, approval or compliance claim: TBC — source required

Packaging and RFQ checklist

The supplied record lists a standard reel length of 2 km. Send the required cut/reel plan for confirmation; do not assume that every order must use one standard reel.

Include the following in the RFQ:

  • Product: GJFJV 1F Riser Simplex Indoor Fiber Optic Cable
  • One fiber grade and one cable diameter
  • Total length, length per reel, quantity and destination
  • Cable marking and label requirements
  • Indoor route, termination method and pathway limits
  • Exact project-required rating or test evidence
  • Required datasheet, drawing, declaration and inspection documents

Datasheet and document area

DocumentOffline status
Current product datasheetTBC — source required
Construction drawingTBC — source required
Model-level riser/fire evidenceTBC — source required
Optical/mechanical test recordTBC — source required

Request a configuration and evidence review

Send BWNFiber the selected fiber grade, cable diameter, total length, reel plan, destination and project rating requirement. The response should confirm the exact product record and identify which datasheet, drawing and test/listing documents are available before quotation approval.

FAQ

Frequently asked questions

What fiber count does this GJFJV page cover?

It covers 1F only. A different fiber count is a separate configuration.

Is this cable simplex or duplex?

It is a simplex cable record with one fiber. A 2F duplex requirement belongs to a separate configuration.

Which fiber grades are listed?

The supplied record lists SM G652, SM G.657.A2, OM1 62.5/125, OM2 50/125, OM3 50/125 and OM4 50/125. Select one grade for the quotation.

What cable diameters are available in the supplied record?

The record lists 1.6 mm, 2 mm and 3 mm. Each size has its own long- and short-term tensile values.

Is the RISER designation proof of OFNR or UL 1666 compliance?

No. This source record does not provide model-level OFNR, UL 1666 or equivalent evidence. Request the exact cable marking and applicable test or listing document.

What bend limit is listed?

The supplied record lists dynamic 20D and static 10D, where D is the selected finished cable diameter.

What is the strength member?

Aramid yarn is listed as the strength member.

Can the cable be used outdoors?

Do not assume so. Outdoor exposure, moisture, UV and entry-transition suitability are not established by this record.

Is the 2 km reel length mandatory?

The record lists 2 km as the standard reel length. State the required length per reel in the RFQ for confirmation.

What should be sent for a quotation?

Send the selected fiber grade and diameter, total length, reel plan, quantity, cable marking, destination, route and required approval evidence.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.