GJFJV
GJFJV 1F Plenum Simplex Indoor Fiber Optic Cable
GJFJV 1F Plenum Simplex Indoor Fiber Optic Cable for indoor building or equipment-room routes at 1F. Confirm jacket and fiber grade before quoting.

Product value summary
BWNFiber’s GJFJV indoor fiber optic cable is a tight-buffered indoor cable family for equipment interconnection and building pathways. The supplied 1F record covers simplex cable options with aramid-yarn strength members and a requested plenum configuration. Select one fiber grade and one cable-diameter build for quotation; do not combine values from different rows.
Approval note for US projects: “Plenum” in the current source is a configuration label, not verified evidence of OFNP, UL listing, or acceptance under a specific building code. Request the exact jacket marking, test report, listing information, and part-number-specific datasheet before project approval.
Short answer
The 1F simplex GJFJV option contains one tight-buffered optical fiber, aramid yarn, and an outer sheath. The supplied draft lists single-mode and multimode fiber alternatives and three nominal cable-diameter builds. The correct order is defined by the exact fiber grade, nominal OD, required project rating, length plan, marking, quantity, and approval documents.
Verified and pending configuration facts
| Attribute | Supplied 1F record | Publication status |
|---|---|---|
| Product family | GJFJV indoor fiber optic cable | First-party draft claim; family is visible on the live BWNFiber site |
| Fiber count | 1F | First-party draft claim |
| Construction visible in supplied image | Sheath, aramid yarn, fiber, 0.9 mm tight buffer | Image-observed; exact material and build mapping TBC |
| Fiber options | SM G652; SM G.657.A2; OM1 62.5/125; OM2 50/125; OM3 50/125; OM4 50/125 | First-party draft claim; confirm exact G.652 subcategory |
| Requested jacket/configuration label | PLENUM | Rating evidence TBC — source required |
| Nominal cable sizes | 1.6 mm; 2 mm; 3 mm | Tolerances and part-number mapping TBC |
| Strength member | Aramid yarn | First-party draft claim and image-observed label |
| Standard reel length | 2 km | TBC — operations/source confirmation required |
| Connectorized ends | Not specified | Treat as bulk cable unless the quotation explicitly includes termination |
Mechanical configuration table
| Nominal cable size | Supplied long-term tensile value | Supplied short-term tensile value | Approval status |
|---|---|---|---|
| 1.6 mm | 40 N | 80 N | TBC — approved source and tolerance required |
| 2 mm | 60 N | 100 N | TBC — approved source and tolerance required |
| 3 mm | 80 N | 150 N | TBC — approved source and tolerance required |
The V4 source states a minimum bend radius of 20D dynamic / 10D static, where D is the finished cable diameter. Keep installation and installed-state limits separate. Confirm the approved finished-cable value for the selected build; the bend performance of the optical fiber alone does not replace the cable-level limit.
Optical characteristics from the supplied record
| Fiber option | Wavelength | Supplied attenuation value | Status |
|---|---|---|---|
| SM G652 | 1310 / 1383 / 1550 nm | 0.36 / 0.36 / 0.22 dB/km | TBC — confirm G.652 subcategory, limit type, and test method |
| SM G.657.A2 | 1310 / 1383 / 1550 nm | 0.36 / 0.36 / 0.22 dB/km | TBC — confirm limit type and test method |
| OM1 62.5/125 | 850 / 1300 nm | 3.0 / 1.0 dB/km | TBC — confirm limit type and test method |
| OM2 50/125 | 850 / 1300 nm | 3.0 / 1.0 dB/km | TBC — confirm limit type and test method |
| OM3 50/125 | 850 / 1300 nm | 3.0 / 1.0 dB/km | TBC — confirm limit type and test method |
| OM4 50/125 | 850 / 1300 nm | 3.0 / 1.0 dB/km | TBC — confirm limit type and test method |
Each row is an alternative fiber configuration. It does not mean that one cable contains all listed fiber types. Transmission reach, network speed, and transceiver compatibility depend on the complete channel and are not established by this table.
Temperature values from the supplied record
| Condition | Supplied value | Status |
|---|---|---|
| Installation | -20°C to +70°C | TBC — approved source/test context required |
| Storage | -20°C to +70°C | TBC — approved source/test context required |
| Operation and transport | -20°C to +70°C | TBC — approved source/test context required |
How to select the correct 1F configuration
- Define the indoor pathway: equipment room, tray, conduit, cabinet, horizontal route, or another documented building zone.
- Select one fiber grade from the approved order matrix. Confirm the exact G.652 designation when applicable.
- Select the cable OD from the approved part-number table, including tolerance, tight-buffer construction, and matching mechanical limits.
- State the exact project-required jacket and fire/smoke rating. Do not approve the cable from the word
PLENUMalone. - Confirm whether the order is bulk cable or a connectorized assembly.
- Approve the datasheet, construction drawing, jacket marking, rating evidence, and applicable test records before the purchase order.
- Fix total length, reel or roll lengths, quantity, marking text, packaging, and destination.
Differences from related BWNFiber pages
- The Indoor Fiber Cable category owns broad family browsing, structure comparison, and pathway selection.
- The existing GJFJV Indoor Fiber Optic Cable page should own GJFJV family specifications and the 1F option table.
- A fiber-selection guide should explain G.652.D versus G.657.A2 or multimode choices; this product page should state only approved available options and ordering boundaries.
- Fiber patch-cord pages should own connectorized assembly intent. Do not imply that this bulk-cable record includes connectors.
Application boundary
Use this cable only for an indoor route that matches the approved part-number record, pathway, jacket/rating evidence, mechanical limits, temperature limits, and termination plan. Outdoor, wet, UV-exposed, direct-burial, armored, or aerial use is not established by the supplied record.
Testing and quality-control area
Before publication, BWNFiber should state only the tests it can document for this exact configuration. The public module should identify:
- selected part number and production length;
- fiber grade and traceable source record;
- attenuation test wavelength, method, limit, and result type;
- dimensional inspection and applicable mechanical checks;
- jacket marking and exact rating evidence;
- reel/roll identification and approved packing record.
Until those records are supplied, show: TBC — request the current datasheet and available approval documents for the selected configuration.
Packaging and procurement
The supplied V4 record lists a standard reel length of 2 km. Confirm availability, tolerance, and packing form for the selected cable size before publishing this as a standard commercial term. Buyers should state total length, preferred length per reel or roll, quantity, marking text, packaging requirement, destination, and required approval documents.
Required RFQ information
- Product family: GJFJV indoor fiber optic cable
- Fiber count: 1F
- Exact fiber grade
- Nominal cable OD and required tolerance
- Tight-buffer requirement
- Jacket material, color, and exact project-required rating
- Indoor pathway and termination method
- Mechanical and temperature requirements
- Bulk cable or connectorized assembly
- Total length and reel/roll plan
- Quantity, marking, packing, destination, and required documents
Primary CTA: Send the pathway, fiber grade, required rating, cable OD, length plan, quantity, and destination for a GJFJV configuration review and quotation.
Secondary CTA: Request the current datasheet, construction drawing, and available rating/test evidence for the selected part number.
CTA copy alternatives
| Priority | CTA | Use condition |
|---|---|---|
| Primary — recommended | Request a GJFJV Configuration Review | Best for organic visitors still validating the technical fit. |
| Primary alternative | Get a GJFJV Quote for My Cable Schedule | Use when the form can accept or attach a cable schedule and route details. |
| Secondary | Request Datasheet and Rating Evidence | Use only when the current files can actually be supplied. |
Conversion and form recommendations
- Keep one primary page action: configuration review / RFQ. Treat datasheet evidence as the secondary action.
- Add a short sentence above the form explaining what the buyer will receive and which inputs produce an accurate response.
- Preserve contact details, but do not force buyers to repeat information already captured in a product-specific RFQ checklist.
- If the current form cannot add structured fields, provide a copyable RFQ template inside the message area rather than inventing a new form workflow.
- Recommended structured fields for a later approved form change: fiber grade, nominal OD, required jacket/rating, route, total length, reel plan, quantity, destination, and document needs.
- Do not claim a response time, quote time, sample availability, or engineering review SLA until Sales/Operations approves it.
- Measure form starts, submissions, accepted leads, configuration-complete leads, opportunities, and mismatch/loss reasons separately; a submission alone is not a qualified inquiry.
Download area
| File | Public status |
|---|---|
| Current part-number datasheet | TBC — source required |
| Construction drawing | TBC — source required |
| Fiber declaration | TBC — source required |
| Jacket/rating evidence | TBC — source required |
| Test-report sample or acceptance format | TBC — source required |
Buyer FAQ
Does this page describe one fiber or multiple fibers?
The supplied configuration is 1F, meaning one optical fiber. Different fiber grades are alternatives for quotation; they are not combined in one cable.
Is the cable automatically OFNP because the source says “PLENUM”?
No. The current source label does not by itself prove OFNP, a UL listing, or project acceptance. Approve the exact part number, jacket marking, test or listing evidence, and local project requirement.
Is G.657.A2 the same as G.652.D?
ITU-T classifies G.657.A2 as bend-insensitive single-mode fiber within category A and describes category A as compliant with G.652.D requirements. For the order, specify the exact fiber grade approved for the project rather than treating the names as interchangeable labels.
What does 20D dynamic / 10D static mean?
D is the finished cable diameter. The dynamic value applies while the cable is being installed or moved; the static value applies after installation. Use the approved cable-level limit for the selected construction.
Which cable diameter should I order?
Choose only from the engineering-approved part-number matrix. The nominal 1.6, 2, and 3 mm options in the supplied draft have different tensile values, but tolerances and full construction mapping still require confirmation.
Can this cable be installed outdoors?
Outdoor suitability is not established by the supplied record. Use only where the exact model documentation covers moisture, UV, temperature, pathway, support, and other environmental conditions.
Is this a finished fiber patch cord?
Not from the supplied record. It should be treated as bulk indoor cable unless the quotation and drawing explicitly define connectors and finished assembly testing.
Which optical value should be used?
Use the row for the selected fiber grade and wavelength. The supplied values still require confirmation of the test method and whether they are maximum or typical limits.
What documents should procurement request?
Request the current part-number datasheet, construction drawing, fiber declaration, dimensions and tolerances, mechanical and temperature limits, jacket/rating evidence, test method, and reel/packing record.
What should be included in the RFQ?
State the 1F requirement, exact fiber grade, cable OD, jacket and project rating, route, termination method, total and per-reel length, quantity, marking, destination, and approval-document list.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.