GCYXTY
GCYXTY 2-24F Unitube Non-Metallic Air-Blown Micro Cable
GCYXTY 2-24F Unitube Non-Metallic Air-Blown Micro Cable for outdoor plant use at 2-24F. Confirm model, fiber count and installation method against the source drawing.

Product Summary
The BWNFiber GCYXTY is a compact, non-metallic unitube cable intended for installation in a microduct by air blowing. The supplied draft describes a gel-filled loose tube, aramid-yarn reinforcement and an HDPE outer sheath. Its stated product scope is 2–24 fibers, with G.652, G.655, 50/125 μm and 62.5/125 μm optical options.
Before requesting a quotation, select one fiber type and one fiber count, then confirm the complete row of cable diameter, reference weight, tensile load, crush load and bend radius. The 14–24F row remains TBC — source required because the available internal draft does not contain a source-consistent fiber-count matrix.
Primary CTA: Request the approved GCYXTY datasheet and a configuration review.
Quick Buyer Answer
Choose this page when the required product is a GCYXTY unitube, non-metallic air-blown micro cable, not a higher-count stranded loose-tube cable. Send BWNFiber the fiber count, fiber grade, microduct dimensions, route length, installation conditions, drum length, quantity, marking text and delivery destination. Engineering confirmation is required before treating the draft dimensions or mechanical values as order specifications.
Key Product Features
- Stated fiber-count scope: 2–24F; the 14–24F source row requires confirmation.
- Central gel-filled unitube construction.
- Aramid yarn used as the non-metallic strength layer.
- HDPE outer sheath.
- Optical options listed in the supplied draft: G.652, G.655, 50/125 μm and 62.5/125 μm.
- Intended installation method: air blowing into a compatible microduct.
These are configuration identifiers, not proof of standards compliance, blowing distance, UV rating, water-blocking test performance or compatibility with a particular duct system.
Construction and Configuration
| Component or parameter | Supplied draft value | Release status |
|---|---|---|
| Product model | GCYXTY | Draft-supported |
| Stated fiber-count range | 2–24F | Hold until the 14–24F matrix is corrected |
| Cable structure | Gel-filled unitube | Draft-supported; datasheet confirmation required |
| Strength layer | Aramid yarn | Draft-supported; datasheet confirmation required |
| Outer sheath | HDPE | Draft-supported; datasheet confirmation required |
| Metallic element | None stated | TBC — approved construction drawing required |
| Loose-tube material and dimensions | Not supplied | TBC — source required |
| Water-blocking compound specification | Not supplied | TBC — source required |
| Sheath color, UV performance and marking | Not supplied | TBC — source required |
Technical Specifications
Mechanical and Dimensional Data
| Catalog model | Fiber count | Cable diameter | Reference weight | Tensile long/short term | Crush long/short term | Bend radius | Status |
|---|---|---|---|---|---|---|---|
| GCYXTY-2~12Xn | 2–12 | 3.5 ± 0.3 mm | 12 kg/km | 60/150 N | 150/450 N/100 mm | 10D/20D | Present in V4; verify against approved source |
| GCYXTY-14~24Xn | TBC | TBC | TBC | TBC | TBC | TBC | Do not quote or publish until BWNFiber corrects the source row |
Do not combine values from different rows. Confirm whether the bend-radius order is static/dynamic or dynamic/static in the approved datasheet before release.
Optical Characteristics
| Fiber option | Attenuation at 1310 nm | Attenuation at 1550 nm | Attenuation at 850 nm | Attenuation at 1300 nm | Bandwidth at 850 nm | Bandwidth at 1300 nm | Cable cutoff wavelength | Numerical aperture | Status |
|---|---|---|---|---|---|---|---|---|---|
| G.652 | ≤0.36 dB/km | ≤0.22 dB/km | — | — | — | — | ≤1260 nm | — | Verify exact G.652 category and source |
| G.655 | ≤0.40 dB/km | ≤0.23 dB/km | — | — | — | — | ≤1450 nm | — | Verify against approved source |
| 50/125 μm | — | — | ≤3.3 dB/km | ≤1.2 dB/km | ≥500 MHz·km | ≥500 MHz·km | — | 0.200 ± 0.015 | Verify exact multimode grade |
| 62.5/125 μm | — | — | ≤3.5 dB/km | ≤1.2 dB/km | ≥200 MHz·km | ≥500 MHz·km | — | 0.275 ± 0.015 | Verify exact multimode grade |
The optical values above are alternatives for different fiber types. They do not all apply to one cable. “G.652” must not be silently rewritten as G.652.D without an approved specification.
Technical notice: Figures in this offline draft are for reference only and are not a quotation or performance guarantee. Use only the values confirmed in the approved, order-specific BWNFiber datasheet and quotation.
Environmental Data
| Parameter | Supplied draft value | Release status |
|---|---|---|
| Storage temperature | −40°C to +70°C | Verify against approved source |
| Operating temperature | −40°C to +70°C | Verify against approved source |
| Installation temperature | Not supplied | TBC — source required |
Interface and Connector Options
This is a bulk optical cable page. No factory-terminated connector, polish, pinning, gender or polarity option is supported by the supplied evidence. If a terminated assembly is required, treat it as a separate product and BOM review rather than adding connector claims to this page.
How to Select the Correct GCYXTY Configuration
- Confirm the page role. Use GCYXTY for the unitube product described here. Do not substitute a stranded GCYFY or GCYFTY configuration merely because it is also installed by air blowing.
- Choose the fiber count. The available draft supports a 2–12F row. Ask BWNFiber to issue a corrected 14–24F row before selecting a higher count.
- Choose one fiber grade. State the exact single-mode or multimode grade; do not list several alternatives as one order configuration.
- Match cable and microduct. Provide the microduct outside and inside diameter, material, route length, bends, occupancy and condition. The page does not prove a blowing distance or duct-to-cable ratio.
- Confirm the mechanical row. Keep diameter, weight, tensile, crush and bend-radius values together and request the applicable test method.
- Define the environment. State installation, operating and storage temperature requirements, plus any UV, water, flame, rodent or chemical exposure requirements.
- Confirm documentation. Ask for the current datasheet, construction drawing, test method, inspection record and packing information applicable to the quoted configuration.
Differences From Related Air-Blown Micro Cables
| Product family | Construction role in supplied local drafts | Stated count range | Use this page when | Do not use this page when |
|---|---|---|---|---|
| GCYXTY | Unitube, aramid-yarn, non-metallic | 2–24F, pending row correction | The buyer needs the exact GCYXTY unitube configuration | The requirement is a higher-count stranded cable |
| GCYFY | Stranded loose tubes around an FRP central member | 24–144F | The project requires the verified GCYFY stranded configuration | A compact GCYXTY unitube configuration is specified |
| GCYFTY-nB1.3 | Stranded loose-tube family | 12–144F | The project specification explicitly calls for that model and row | The BOM calls for GCYXTY |
This table distinguishes page ownership; it is not an equivalence or compatibility statement. Confirm each related product against its approved datasheet.
Application Conditions
The supported application statement is microduct cable installation by air blowing. Before approval, confirm the cable-to-duct fit, route geometry, installation equipment and pressure limits with the microduct and blowing-equipment documentation. The current evidence does not support claims for direct burial, aerial self-support, indoor flame-rated use, rodent resistance, a guaranteed blowing distance or a particular network reach.
Testing and Quality-Control Information to Request
The supplied evidence does not include a BWNFiber test plan or test report. For technical validation, request configuration-specific evidence for:
- fiber identity and count;
- cable outside diameter and mass;
- attenuation at the specified wavelengths;
- tensile and crush test method and limits;
- bend-radius interpretation;
- temperature ranges;
- construction and material verification;
- cable length, marking and drum inspection;
- any claimed standards or environmental performance.
These are requested evidence items, not statements that a test has been completed or passed.
Packaging and Procurement Information
Packing type, standard delivery length, maximum drum length, MOQ, price, lead time, warranty, country of origin and export documentation are TBC — source required. State them in the quotation only after Sales or Supply Chain confirms the exact order.
Information Required for an RFQ
Send the following information for a configuration review and quotation:
- product model: GCYXTY;
- required fiber count;
- exact fiber grade;
- total cable length and length per drum;
- microduct outside and inside diameter;
- route length, number of bends and installation method;
- installation, operating and storage conditions;
- required cable marking and sheath color;
- quantity and delivery destination;
- required datasheet, drawing, test record, inspection or packing documents;
- target delivery date, stated as a request rather than an assumed commitment.
Downloads
- Approved GCYXTY datasheet:
TBC — source required - Corrected 2–24F configuration matrix:
TBC — source required - Construction drawing:
TBC — source required - Test method and configuration-specific inspection record:
TBC — source required - Packing and drum-length document:
TBC — source required
Frequently Asked Questions
What fiber counts does this GCYXTY page cover?
The intended page scope is 2–24 fibers. The 2–12F row is present in the supplied V4 draft, but the 14–24F source row is inconsistent and must be corrected before publication or quotation.
Is GCYXTY a unitube or stranded loose-tube cable?
The supplied BWNFiber draft identifies GCYXTY as a unitube cable. The stranded GCYFY and GCYFTY families should remain separate product pages because they have different structures and configuration ranges.
Is this cable metallic?
The supplied draft describes a non-metallic construction with aramid yarn. Confirm the approved construction drawing before stating that no metallic element is present in every offered configuration.
Which fiber type should I specify?
Choose one exact grade based on the network design and approved product specification. The draft lists G.652, G.655, 50/125 μm and 62.5/125 μm as alternatives; it does not mean that all types apply to one cable.
Can I specify G.652.D?
Only after the approved datasheet or quotation confirms G.652.D. The current source says G.652, so the page must not add a subtype by assumption.
What microduct size is required?
No approved duct-size range is supplied. Provide the cable diameter, microduct inside diameter, route length, bends and equipment details to the responsible engineer for a compatibility review.
How far can this cable be blown?
The current evidence does not support a guaranteed blowing distance. Distance depends on the cable and duct pair, route geometry, equipment, pressure, lubrication where applicable and installation conditions.
What do the tensile and crush values mean?
They are long-term and short-term limits stated in the draft. Request the approved test method and row-specific values, and do not use a short-term value as a continuous service rating.
Is the cable suitable for direct burial, aerial installation or indoor use?
Those uses are not established by the supplied evidence. This page should claim only microduct air-blown installation until the relevant construction, rating and application documents are approved.
What should I request before placing an order?
Request the current datasheet, corrected configuration matrix, construction drawing, applicable test method, configuration-specific inspection documents and confirmed packing terms.
What should I include in the quotation request?
Include the model, fiber count and grade, microduct dimensions, route conditions, total and drum lengths, quantity, marking, delivery destination and required documents.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.