Outdoor Fiber Cable

GCYFTY-nB1.3 12–144F Stranded Loose Tube Air-Blown Micro Cable

GCYFTY-nB1.3 12–144F Stranded Loose Tube Air-Blown Micro Cable for outdoor plant use at 12F / 24F / 36F / 48F / 72F / 96F / 144F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

GCYFTY-nB1.3

Product Value Summary

The GCYFTY-nB1.3 is a stranded loose tube fiber optic cable intended for air-blown installation in a microduct route. The supplied BWNFiber record identifies an HDPE outer sheath. Before quotation or production, the exact fiber count, fiber grade, cable diameter, mechanical limits, bend radius, microduct pairing, drum length, and test requirements must be confirmed for one configuration.

Buyer short answer: Use this page to identify the GCYFTY-nB1.3 cable family and prepare a technically complete RFQ. Do not select a cable from a family-level fiber-count range alone; match one approved configuration to the route, microduct, installation equipment, and acceptance requirements.

Request an engineering-reviewed configuration: Send the required fiber count, fiber grade, route length, microduct inside diameter, route geometry, installation method, drum-length plan, destination, and quantity. BWNFiber must confirm the applicable product row before quotation.

Key Features

  • Stranded loose tube cable construction — stated in the supplied BWNFiber draft; final construction drawing required.
  • Intended for air-blown microduct installation — stated in the supplied BWNFiber draft.
  • HDPE outer sheath — stated in the supplied BWNFiber draft; compound, thickness, UV performance, and marking requirements are not yet verified.
  • Multiple fiber-count configurations are referenced in the supplied record, but the count-to-parameter matrix is incomplete and must be reconciled before publication.
  • Configuration-specific dimensions and mechanical limits must remain attached to the approved row; values from different rows must not be combined.

Technical Specifications — Publication-Hold Version

SpecificationCurrent evidence-safe entryPublication status
ModelGCYFTY-nB1.3Supported by supplied draft
Cable typeStranded loose tube air-blown micro cableSupported by supplied product name
Intended installationAir-blown installation in a microduct routeSupported by supplied draft
Outer sheathHDPESupported by supplied draft; detailed compound data TBC
Fiber-count optionsTBC — source requiredHeader names 12F, 24F, 36F, 48F, 72F, 96F and 144F; matrix omits 36F/72F and duplicates 96F
Fiber gradeTBC — source requiredOptical table lists alternatives but does not map them to orderable configurations
Fibers per tubeTBC — source requiredEngineering-approved row mapping required
Loose-tube/filler countTBC — source requiredEngineering-approved row mapping required
Cable diameterTBC — source requiredRetain by exact configuration only
Cable weightTBC — source requiredRetain by exact configuration only
Long-/short-term tensile strengthTBC — source requiredTwo 96F rows conflict without distinct SKU or configuration labels
Long-/short-term crush resistanceTBC — source requiredTest method and row applicability required
Operating temperatureTBC — source requiredEngineering approval required
Installation temperatureTBC — source requiredEngineering approval required
Storage temperatureTBC — source requiredEngineering approval required
Minimum bend radiusTBC — source requiredSupplied editorial note says source values were excluded pending correction
Compatible microduct inside diameterTBC — source requiredRequired for selection; absent from supplied record
Maximum qualified blowing distance/speedTBC — source requiredDepends on tested cable/duct/route/equipment conditions; no BWNFiber evidence supplied
Applicable standards/test methodsTBC — source requiredDo not infer compliance from competitor documents
Standard drum length and toleranceTBC — source requiredNeeded for logistics and RFQ

Configuration Matrix Required Before Publication

BWNFiber engineering should issue one approved row per orderable configuration. Each row should include:

  1. Unique configuration or SKU identifier.
  2. Fiber count and fiber grade.
  3. Fibers per tube and loose-tube/filler count.
  4. Cable outside diameter and tolerance.
  5. Cable weight and tolerance.
  6. Long- and short-term tensile limits with test method.
  7. Long- and short-term crush limits with test method.
  8. Loaded and unloaded minimum bend radius.
  9. Operating, installation, and storage temperature ranges.
  10. Compatible microduct inside diameter or approved fill-ratio guidance.

Interfaces and Connector Options

This product is described as an unterminated outdoor cable, not a connectorized cable assembly. Connector type, polish, gender, pinning, and polarity therefore do not belong in the base cable specification unless the commercial offer includes a terminated assembly.

Termination or breakout options: TBC — source required. If a project requires factory termination, define it as a separate approved assembly or BOM rather than silently adding connector claims to this cable page.

Fiber Type and Configuration Options

The supplied optical tables mention G.652.D, G.657.A1, G.657.A2 and several multimode grades. They do not prove that every grade is orderable in every GCYFTY-nB1.3 construction. The page should publish only the combinations shown on an approved BWNFiber datasheet or configuration matrix.

For an RFQ, specify one fiber grade and one fiber count. Do not combine wavelength, attenuation, bandwidth, or dimensional values from alternative columns.

Compatibility and Application Conditions

The intended application is installation by air blowing into a microduct route. Final compatibility cannot be established from cable diameter alone. The project review should confirm:

  • Microduct inside diameter, material, length, joints, and condition.
  • Route geometry, including bends, elevation changes, and access points.
  • Cable outside diameter and tolerance for the selected configuration.
  • Blowing machine and compressor limits.
  • Lubricant and installation procedure, where applicable.
  • Ambient and installation temperature.
  • Required installation length per blowing section.
  • Acceptance criteria after installation.

The supplied material does not establish direct-burial, aerial, indoor flame-rating, rodent-resistant, or armored use. Do not use this page to claim those applications unless separate product evidence supports them.

How to Select the Correct Configuration

  1. Define the route. Record the microduct inside diameter, route length, bends, elevation changes, access points, and environmental conditions.
  2. Select the fiber requirement. State fiber count, fiber grade, and any customer or carrier specification.
  3. Match one approved cable row. Confirm diameter, weight, tube layout, tensile/crush limits, and bend radius for that exact configuration.
  4. Check installation compatibility. Confirm the cable-to-duct pairing and blowing-equipment settings through the approved BWNFiber procedure or project review.
  5. Set logistics and identification. Define total length, length per drum, quantity, marking text, destination, and required packaging documents.
  6. Agree on evidence and acceptance. Identify the datasheet, drawing, test report or certificate of conformity required for the order.

Differences From Related Cable Types

Cable typePrimary roleSelection boundary
GCYFTY-nB1.3 air-blown micro cableInstallation into an approved microduct routeRequires cable-to-microduct and blowing-condition confirmation
Conventional duct cableInstalled in a duct by an approved pulling or blowing methodDo not assume the same diameter, friction behavior, or installation limits
ADSS cableSelf-supporting aerial installationRequires span, wind, ice, sag, and hardware design; not interchangeable with this product
Direct-burial armored cableBuried route requiring the specified mechanical protectionDo not claim direct-burial suitability for GCYFTY-nB1.3 without evidence
Indoor-rated cableIndoor route with the required fire/smoke classificationHDPE alone does not establish an indoor fire rating

Use Cases

  • Microduct routes where the selected cable and duct combination has been approved.
  • Access, metro, or backbone projects that specify an air-blown stranded loose tube cable.
  • Capacity additions in a prepared microduct pathway, subject to route and installation review.

These are application categories, not proof of suitability for a specific project. Engineering must confirm the exact environment and acceptance requirements.

Testing and Quality-Control Process

TBC — source required. Before publication, BWNFiber should confirm which of the following are standard, optional, or unavailable for this product:

  • Incoming fiber verification.
  • In-process dimensional checks.
  • Cable attenuation testing by wavelength and fiber grade.
  • Tensile, crush, bend, temperature, and water-related test methods.
  • Drum-length and cable-marking inspection.
  • Final test report, certificate of conformity, or customer-specific inspection record.

Do not state that every cable or every drum receives a named test unless an approved process record supports that claim.

Packaging and Procurement Information

ItemRequired entry
Standard drum lengthTBC — source required
Length toleranceTBC — source required
Drum material and dimensionsTBC — source required
Cable-end sealingTBC — source required
Marking formatCustomer requirement plus BWNFiber-approved marking template
Export packagingTBC — source required
MOQ, price, lead time, warrantyQuotation-specific; do not use for order release without current commercial approval

Required Information for an RFQ

Send:

  • Product model: GCYFTY-nB1.3.
  • Required fiber count and fiber grade.
  • Microduct inside diameter and route information.
  • Total cable length and length per drum.
  • Quantity and delivery destination.
  • Installation environment and temperature range.
  • Required tensile, crush, bend, water, or other project criteria.
  • Cable marking and packaging requirements.
  • Required standards, test methods, documents, or witness inspection.
  • Project timeline and any sample requirement.

Primary CTA: Request an engineering-reviewed GCYFTY-nB1.3 configuration and quotation.
Secondary CTA: Request the approved datasheet, drawing, and available test-document list.

Datasheet, Drawing, and Test-Report Area

  • Approved product datasheet: TBC — source required
  • Approved construction drawing: TBC — source required
  • Configuration matrix: TBC — source required
  • Available test-report list: TBC — source required
  • Installation or cable-blowing procedure: TBC — source required

Only publish download buttons for controlled documents that match the page model and revision.

FAQ

Frequently Asked Questions

What is the GCYFTY-nB1.3 cable?

It is identified in the supplied BWNFiber record as a stranded loose tube fiber optic cable for air-blown installation in a microduct route, with an HDPE outer sheath. The final construction drawing and configuration matrix still require engineering approval.

Which fiber counts are available?

TBC — source required. The supplied header names 12F, 24F, 36F, 48F, 72F, 96F and 144F, but the detailed table omits 36F and 72F and contains two unlabeled 96F columns. Publish the range only after those rows are reconciled.

Which fiber grades can be ordered?

TBC — source required. The supplied optical tables list several single-mode and multimode grades, but they do not map each grade to an orderable GCYFTY-nB1.3 configuration.

Is this cable all-dielectric?

TBC — source required. Do not infer an all-dielectric claim from the model name or from competitor products; confirm the approved construction and every strength or blocking element.

What microduct size should be used?

The compatible microduct inside diameter is not confirmed in the supplied record. Provide the cable diameter tolerance, duct inside diameter, route geometry, and blowing-equipment details for project review.

What are the cable diameter and weight?

They vary by configuration. The current source matrix requires engineering correction, so the page should not publish a count-to-diameter or count-to-weight value until the applicable rows are approved.

What tensile and crush limits apply?

TBC — source required. Use only the values tied to the selected configuration and the stated test method. Do not treat a short-term limit as a continuous service rating.

What minimum bend radius applies during installation?

TBC — source required. The supplied editorial record says the source bend-radius rows were excluded pending engineering correction.

How far can the cable be blown?

No product-specific qualified distance is supplied. Installation distance depends on the cable, microduct, route geometry, joints, equipment, airflow, lubricant, and site conditions. Request a project-specific review instead of using a competitor’s distance claim.

Is the cable suitable for direct burial or aerial installation?

Not established by the supplied evidence. This draft supports air-blown microduct use only. Choose a separately approved armored direct-burial or ADSS product for those routes.

What should be included in the quotation request?

Provide the model, fiber count and grade, microduct data, route and environment, total length, length per drum, quantity, marking, packaging, destination, required documents, and project schedule.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.