Fiber Patch Cord

CS/UPC to LC/APC Uniboot Patch Cord

BWNFiber CS/UPC to LC/APC Uniboot Patch Cord is a hybrid duplex single-mode fiber patch cable designed for high-density data center, telecom, ODF, FTTH/ODN and optical distribution applications. One end uses a genuine SENKO CS®/UPC VSFF duplex connector, while the opposite end uses a standard LC/APC duplex connector. Built with G.657A1 bend-insensitive single-mode fiber and a 2.0mm round duplex LSZH jacket, this uniboot patch cord reduces cable bulk, improves routing in crowded racks and supports cleaner cable management in high-port-count environments.

✓ Genuine SENKO CS® connector ✓ 100% IL/RL tested ✓ Custom length & OEM packaging

What Is a CS/UPC to LC/APC Uniboot Patch Cord?

A CS/UPC to LC/APC Uniboot Patch Cord is a hybrid duplex fiber cable used to connect SENKO CS® VSFF interfaces to LC/APC equipment, ODFs, distribution frames or optical network systems.

The CS® side is suitable for high-density data center ports, VSFF patch panels and next-generation transceiver-related cabling. The LC/APC side provides angled-polish connectivity for APC-based equipment, FTTH/ODN distribution systems and optical networks where lower back reflection is required. This makes the cable especially useful when customers need to bridge new CS® VSFF connectivity with existing LC/APC infrastructure.

Why Choose BWNFiber CS to LC Uniboot Patch Cord?

Genuine SENKO CS®/UPC Connector

Supports high-density VSFF connectivity and reliable mating with CS®-enabled ports and panels.

LC/APC Duplex Opposite End

Suitable for APC-based ODF, FTTH/ODN and optical systems where low back reflection matters.

G.657A1 Bend-Insensitive Fiber

Better routing performance in compact racks, cabinets and high-density patching fields.

2.0mm Round Duplex LSZH Cable

Lower cable bulk and cleaner cable management compared with traditional zipcord duplex cables.

100% IL/RL Factory Testing

Each unit can be supplied with an individual label showing serial number, length, IL and RL values.

Custom Length & OEM Packaging

Built for project BOMs, rack deployment and customer labeling requirements.

Technical Specifications

Product NameCS/UPC – LC/APC Uniboot G657A1 DX 2.0mm LSZH Patch Cord
Fiber ModeSingle-mode OS2, 9/125µm
Fiber TypeITU-T G.657A1 bend-insensitive fiber
Fiber CountDuplex, 2 fibers
Connector ASENKO CS® / UPC
Connector BLC / APC
Polish TypeUPC on CS side, APC on LC side
Cable Type2.0mm round duplex cable
Jacket MaterialLSZH
Jacket ColorYellow
Typical Insertion Loss0.05–0.15 dB per channel
Maximum Insertion Loss≤0.30 dB assembly acceptance
Return Loss, UPC Side≥50 dB assembly acceptance; premium target ≥55 dB
Return Loss, APC Side≥60 dB assembly acceptance; premium target ≥65 dB
Minimum Bend Radius10mm fiber-level reference for G.657A1
Operating Temperature-40°C to +75°C / +85°C depending on project specification
Storage Temperature-40°C to +85°C
Durability500 mating cycles typical
Tensile StrengthApprox. 200N installation tensile strength for 2.0mm round duplex cable
Test StandardsIEC 61300-3-4 for insertion loss; IEC 61300-3-6 for return loss
Compliance ReferenceGR-326-CORE, TIA-568, RoHS, REACH, UL94 V-0 / LSZH material reference

Applications

BWNFiber CS/UPC to LC/APC Uniboot Patch Cord is suitable for:

  • High-density data center patching
  • 200G / 400G / 800G optical connectivity
  • CS® VSFF patch panels and transceiver links
  • ODF and high-density fiber distribution frames
  • Telecom central office cabling
  • FTTH / ODN equipment requiring APC termination on one side
  • High-density pre-terminated fiber assemblies
  • Space-limited cabinet and rack environments
CS to LC uniboot patch cord for high-density data center and ODF cabling

Product Advantages

High-Density VSFF to LC Connectivity

The SENKO CS® connector side helps support high-density Base-2 optical connectivity, while the LC/APC side allows the cable to connect with widely deployed APC-based LC equipment. This makes the cable practical for projects where new high-density CS® interfaces need to be integrated with existing LC/APC infrastructure.

Cleaner Cable Management with Uniboot Structure

Compared with traditional duplex zipcord patch cords, the 2.0mm round duplex uniboot structure helps reduce cable congestion and improves cable routing in high-density patch panels, racks and cabinets.

Factory-Tested IL/RL Performance

Each cable can be supplied with a label showing the serial number, cable length, insertion loss and return loss values. The attached 5m sample test data shows insertion loss values from 0.05 dB to 0.14 dB and return loss values from 54.1 dB to 61.7 dB.

Custom Built for Project BOMs

BWNFiber can support custom cable length, G.657A1 or G.657A2 fiber options, 2.0mm standard cable, evaluated compact cable structures, LSZH jacket, custom polarity, boot color, pull-tab length, product label, OEM packaging and 100% IL/RL test report before shipment.

Ordering Guide

Ordering Code

BWN-CSUPC-LCAPC-G657A1-DX2.0-LSZH-XXM

Code SectionMeaningAvailable Options
BWNBWNFiber product prefixFixed
CSUPCConnector ASENKO CS® / UPC
LCAPCConnector BLC / APC
G657A1Fiber typeG.657A1 bend-insensitive single-mode fiber
DXFiber countDuplex, 2 fibers
2.0Cable diameter2.0mm round duplex cable
LSZHJacket materialLSZH, yellow
XXMCable length1M, 2M, 3M, 5M, 10M, or customized

Standard Ordering Examples

Ordering CodeDescription
BWN-CSUPC-LCAPC-G657A1-DX2.0-LSZH-1MCS/UPC to LC/APC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 1 meter
BWN-CSUPC-LCAPC-G657A1-DX2.0-LSZH-3MCS/UPC to LC/APC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 3 meters
BWN-CSUPC-LCAPC-G657A1-DX2.0-LSZH-5MCS/UPC to LC/APC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 5 meters
BWN-CSUPC-LCAPC-G657A1-DX2.0-LSZH-10MCS/UPC to LC/APC Uniboot duplex patch cord, G.657A1, 2.0mm LSZH, 10 meters

Customization Options

ItemCustom Options
Cable LengthCustomized length available on request
Fiber TypeG.657A1 standard; G.657A2 optional
Cable Diameter2.0mm standard; other compact cable structures can be evaluated by project
Jacket MaterialLSZH standard
Jacket ColorYellow standard for single-mode
Connector BrandGenuine SENKO CS® connector
PolarityStandard duplex polarity; custom polarity available on request
Pull Tab / BootStandard push-pull boot; custom boot color or pull-tab length available on request
LabelS/N, length, connector type, IL/RL test data
PackagingIndividual PE bag; OEM label and carton marking available
Test Report100% IL/RL test report available before shipment

How to Request a Quote

To quote the correct CS to LC Uniboot Patch Cord, please send us:

  • Connector type: CS/UPC to LC/APC
  • Fiber type: G.657A1 or G.657A2 single-mode
  • Cable diameter: 2.0mm round duplex cable or other required structure
  • Jacket material: LSZH
  • Cable length: 1m / 3m / 5m / 10m / customized
  • Quantity
  • Label and packaging requirements
  • Polarity or equipment-side connection requirements
FAQ

CS/UPC to LC/APC Uniboot Patch Cord FAQ

What is a CS/UPC to LC/APC Uniboot Patch Cord?

A CS/UPC to LC/APC Uniboot Patch Cord is a hybrid duplex single-mode fiber cable with a SENKO CS®/UPC VSFF connector on one end and an LC/APC duplex connector on the other end. It is used to connect high-density CS® VSFF ports to LC/APC-based equipment, ODFs, FTTH distribution frames and optical network systems.

What is the main advantage of CS to LC Uniboot Patch Cord?

The main advantage is that it bridges high-density CS® VSFF connectivity with widely used LC/APC infrastructure. The uniboot structure also helps reduce cable bulk and improve routing in high-density racks and patch panels.

Is this patch cord suitable for 400G and 800G data center cabling?

Yes. The product is designed for high-density optical connectivity and is suitable for 200G, 400G and 800G data center cabling environments.

What fiber type is used in this CS to LC patch cord?

The standard fiber type is ITU-T G.657A1 bend-insensitive single-mode fiber. G.657A2 can also be evaluated or supplied based on project requirements.

What cable jacket is used?

The standard jacket is 2.0mm round duplex LSZH cable, yellow color for single-mode applications.

Can BWNFiber customize the length?

Yes. Standard examples include 1m, 3m, 5m and 10m. Customized lengths are available based on project BOMs.

Can BWNFiber provide IL/RL test reports?

Yes. Each patch cord can be 100% factory tested, and the label can show serial number, length, connector type, insertion loss and return loss values.

Where is this CS/UPC to LC/APC patch cord used?

It is used in high-density data center patching, CS® VSFF patch panels, transceiver links, ODFs, FTTH/ODN equipment, telecom central offices, high-density distribution frames and space-limited rack environments.