Blockless Mini PLC Splitter

BWN-PLC-MMST-2X32-LC-APC Steel Tube 2×32 LC/APC Fiber Optic Cable Splitter

2×32 PLC splitter in a steel tube package, terminated with LC/APC connectors: two inputs and 32 outputs (34 LC ports) for high-density PON distribution in splice closures and fiber distribution boxes. Model BWN-PLC-MMST-2X32-LC-APC covers 1260-1650nm with 17.5dB max insertion loss and -40~+85°C operation.

Overview: 2×32 PLC Splitter in a Steel Tube with LC/APC

The BWN-PLC-MMST-2X32-LC-APC is a planar lightwave circuit (PLC) splitter that distributes two optical inputs evenly across 32 outputs inside a compact steel tube, factory-terminated with LC/APC connectors. It serves PON and FTTx distribution points that need dual-input architecture and high connector density in a splice-in package.

This configuration fits ISPs, FTTH contractors, and passive optical LAN builders who run out of tray space before link budget. One tube carries 34 LC connections — two inputs plus 32 outputs — and drops into a splice closure or distribution box; LC’s 1.25mm ferrule lets a tray position hold roughly twice as many terminations as SC’s 2.5mm ferrule. With 17.5dB maximum insertion loss and 1.8dB uniformity, it supports redundant-OLT feeding and GPON/XGS-PON coexistence. For concept background, see our fiber optic splitter overview and the PLC splitter category.

Key Features

  • 2 inputs × 32 outputs in one steel tube: 34 LC/APC ports in a splice-in package — the densest connectorized steel-tube splitter in the BWNFiber range.
  • 17.5dB max insertion loss, 1.8dB uniformity: every one of the 32 outputs lands inside a predictable budget window.
  • LC/APC small-form-factor connectors: 1.25mm ferrule versus 2.5mm on SC, so closures and boxes terminate about double the ports per position.
  • 55dB return loss, 55dB directivity: APC-grade reflection control for PON links that also carry RF video wavelengths.
  • 1260-1650nm full band, 0.5dB wavelength dependent loss: transparent to 1310/1490/1550/1577nm services sharing one ODN.
  • -40~+85°C operating and storage, 0.5dB temperature stability: rated for sealed closures and outdoor cabinets.
  • G657A bend-insensitive pigtails: 0.9mm, 2.0mm, or 3.0mm diameter, 1m standard or customized.

Specifications

Values below are the 2×32 column of the BWNFiber 2×N PLC specification table, plus this model’s configuration list.

ParameterBWN-PLC-MMST-2X32-LC-APC (2×32)
Splitter typePLC, steel tube package
Configuration2 inputs × 32 outputs
ConnectorLC/APC (options: SC/LC/ST, APC or UPC)
Fiber typeG657A or customer specified
Fiber diameter0.9mm / 2.0mm / 3.0mm
Fiber length1m or customized
Operating wavelength1260~1650nm
Insertion loss (max)17.5dB
Loss uniformity1.8dB
Return loss55dB
Polarization dependent loss0.4dB
Directivity55dB
Wavelength dependent loss0.5dB
Temperature stability (-40~+85°C)0.5dB
Operating / storage temperature-40~+85°C
PLC device dimension (L×W×H)60×7×4mm
ComplianceTelcordia GR-1209-CORE, GR-1221-CORE(per BWNFiber product documentation)

Note: the 120×80×18mm module dimension in the family table refers to the ABS module package, not this steel-tube unit.

Connectors, Fiber Types & Compatibility

The standard build is LC/APC on G657A bend-insensitive fiber. APC’s angled endface keeps return loss at 55dB, which matters when PON wavelengths share plant with RF video. SC, LC, and ST connectors in APC or UPC polish are available options per the configuration list — never mate APC pigtails into UPC adapters. Use 0.9mm pigtails inside splice trays; 2.0mm and 3.0mm jacketed leads suit runs leaving the enclosure. The tube splices directly into fiber optic splice closures, distribution boxes, and ODF adapter fields.

Applications

  • GPON + XGS-PON coexistence: both OLT services enter the two inputs and reach all 32 outputs, so a GPON ODN can overlay XGS-PON without re-splicing.
  • Redundant OLT feeding: with main and standby OLT ports on the two inputs, all 32 subscribers stay lit through a port or line-card failure.
  • Dense FTTH distribution closures: 34 LC terminations where the same tray position would hold roughly half as many SC connectors.
  • CATV/RF video overlay on PON: 55dB return loss at APC polish protects reflection-sensitive video wavelengths.
  • Passive optical LAN risers: the tube mounts inside wall boxes and riser enclosures where cassette or LGX frames do not fit. See related FTTx supporting products for the enclosure side.

How to Choose: Split Count, Connector, Package, Pigtail

  • 1×32 or 2×32: a single OLT feed only needs a 1×32 splitter. Choose 2×32 when you plan redundant feeding or a two-service overlay — both inputs distribute to every output.
  • LC or SC: choose LC (this page) when tray and panel positions are the constraint; choose SC when field crews standardize on SC handling.
  • Steel tube or housed: tube for splice closures and small boxes; cassette for FDH adapter plates; LGX or rack for ODF frames. The blockless mini PLC splitter category covers smaller split counts in the same tube format.
  • Polish: APC for PON with RF video overlay; UPC where the reflection budget is relaxed.
  • Pigtail: 0.9mm for tray routing, 2.0/3.0mm where leads exit the box; 1m standard, custom lengths on request.

Sibling Configurations vs This 2×32 LC/APC Steel Tube

This page keeps one combination: 2×32, LC/APC, steel tube. Adjacent needs belong to sibling pages:

If you needChoose
Steel tube with fewer ports (2×8) and SC/APC2×8 steel tube PLC splitter SC/APC
2×32 mounted on FDH adapter plates, SC/APCcassette PLC splitter range
1×32 or 1×64 in a 19-inch ODF framerack-mounted PLC splitter range
LC density in an LGX box (2×8 LC/UPC)LGX box LC/UPC 2×8 PLC splitter

None of the siblings pack 34 LC ports into a splice-in tube — that is the gap this model fills.

Testing & Quality Control

Optical performance is verified against the parameters in the specification table above. Compliance with Telcordia GR-1209-CORE and GR-1221-CORE is stated per BWNFiber product documentation.

Packaging & Ordering Information

Standard pigtail length is 1m; lengths, diameters (0.9/2.0/3.0mm), and connector options are configurable on order.

Request a Quote

To price this splitter, send an inquiry with six items: (1) split configuration — 2×32; (2) package — steel tube; (3) connector and polish — LC/APC; (4) pigtail diameter — 0.9/2.0/3.0mm; (5) pigtail length — 1m or custom; (6) quantity. Our team will reply with specifications, pricing, and delivery support. Contact BWNFiber or use the inquiry form on this page.

FAQ

BWN-PLC-MMST-2X32-LC-APC Steel Tube 2×32 LC/APC Fiber Optic Cable Splitter FAQ

What does 2×32 mean on a PLC splitter, and when do I need dual inputs?

2×32 means two input fibers distribute evenly to 32 output fibers — every output sees both inputs. Choose dual inputs for redundant OLT feeding (main plus standby) or two services such as GPON and XGS-PON over one distribution plant. A single OLT feed needs only a 1×32 splitter.

Why choose LC/APC over SC/APC on a 32-port splitter?

Density. A 2×32 unit terminates 34 connectors, and LC’s 1.25mm ferrule is half the size of SC’s 2.5mm ferrule, so a splice tray holds roughly twice as many LC terminations per position. The trade-off: SC handles more easily with gloves. Choose LC when space is the binding constraint.

Does 17.5dB insertion loss fit a GPON link budget?

Yes. GPON Class B+ allows a 28dB budget; 17.5dB max splitter loss leaves about 10dB for fiber, splices, connectors, and repair margin. XGS-PON N1 allows 29dB. The table value is the splitter device — add connector-pair loss per your project spec, and check our splitter loss chart (1×2 to 1×64) when comparing ratios.

Why is APC polish standard for PON splitters?

APC’s angled endface steers reflected light out of the guided path; this model specifies 55dB return loss, protecting analog-sensitive CATV/RF video wavelengths sharing PON infrastructure. For data-only links with relaxed reflection budgets, UPC is an option. Never mate APC to UPC — the endfaces do not seat.

When should I pick the steel tube instead of a cassette or rack splitter?

Pick the steel tube when the splitter lives in a splice closure, small distribution box, or riser enclosure and is fusion-spliced into the plant. Pick a cassette for FDH adapter plates, or a rack/LGX module for 19-inch ODF frames. Optical performance is the same 2×N family; the package follows the mounting point.

What are the dimensions and pigtail options for this 2×32 model?

The PLC device measures 60×7×4mm. The family table lists no mini-module size for 2×32 (N/A) — the chip plus 34 fan-out leads exceed that package class — so the finished tube dimension is. Pigtails are G657A in 0.9/2.0/3.0mm, 1m standard or customized.