Overview
The BWN-PLC-IM-2X16-SC-UPC is a 2×16 PLC (planar lightwave circuit) optical splitter in an ABS box module, factory-terminated with SC/UPC connectors. It accepts up to two input fibers and distributes each input signal evenly across 16 output ports over the full 1260-1650nm window, so one feeder can serve 16 drop lines in PON, FTTH, CATV and enterprise networks.
Order this configuration when you need 16 drops per feeder plus a second input for a protection feed or a second service, and when the installed plant is UPC-polished. The 120×80×18mm ABS module sits inside splice trays, distribution boxes and ODFs; it is not a sealed outdoor enclosure on its own. If your build specifies SC/APC, or you need a steel-tube mini module for splice closures, use the sibling models linked below. For category context, see the PLC splitter category and the fiber optic splitter overview.
Key Features
- 2×16 dual-input architecture — two input ports each fan out to the same 16 SC/UPC outputs; run a redundant feeder or second service without a second splitter.
- 14.4dB max insertion loss, 1.5dB uniformity — per-subscriber optical budget variation stays within a 1.5dB window across all 16 ports.
- Broadband 1260-1650nm operation — one splitter passes 1310/1490nm GPON traffic and 1550nm video overlay alike — wavelength-independent power splitting, not wavelength multiplexing.
- 55dB return loss, 55dB directivity — back-reflection into the feeder stays controlled on UPC links.
- -40~+85°C operating and storage range — 0.5dB temperature stability across that span, rated for unconditioned cabinets and closures.
- 120×80×18mm ABS box — drop-in module for splice trays and distribution boxes.
Specifications
Values: 2×16 column of the 2×N PLC specification table, plus the page specification list.
| Parameter | Value |
|---|
| Configuration | 2×16 (2 inputs × 16 outputs) |
| Splitter Type | ABS Box Type |
| Connector (this unit) | SC/UPC (family options: SC/LC/ST, APC/UPC) |
| Operating Wavelength | 1260-1650nm |
| Fiber Type | G657A or customer specified |
| Insertion Loss (max) | 14.4 dB |
| Loss Uniformity (max) | 1.5 dB |
| Return Loss (min) | 55 dB |
| Polarization Dependent Loss (max) | 0.3 dB |
| Directivity (min) | 55 dB |
| Wavelength Dependent Loss (max) | 0.5 dB |
| Temperature Stability, -40~+85°C (max) | 0.5 dB |
| Operating Temperature | -40~+85°C |
| Storage Temperature | -40~+85°C |
| Device Dimension (L×W×H) | 50×7×4 mm |
| Module Dimension (L×W×H) | 120×80×18 mm |
| Mini-Module Dimension (family reference) | 80×20×6 mm |
| Fiber Diameter | 0.9mm / 2.0mm / 3.0mm |
| Fiber Length | 1m or customized |
| Compliance | Telcordia GR-1209-CORE, GR-1221-CORE |
Connectors, Fiber Types & Compatibility
This unit ships with SC/UPC connectors (blue housings). Mate it only with UPC-polished jumpers: plugging a UPC connector into an APC (green, 8° angled) adapter leaves an air gap, risks end-face damage, and collapses return loss at that joint. Family options: SC, LC or ST interfaces, APC or UPC polish; G657A bend-insensitive singlemode or customer-specified fiber at 0.9/2.0/3.0mm diameter, 1m standard leads.
The 1260-1650nm window covers the common PON wavelength plans — 1310nm upstream and 1490nm downstream for GPON, 1270/1577nm for XGS-PON — plus 1550nm RF video overlay, so one splitter carries mixed services without reconfiguration. One clarification: this is a broadband power splitter, not a WDM — it splits optical power evenly at any wavelength in the window and does not combine or separate wavelength channels. For CWDM/DWDM channel multiplexing, contact our team for the WDM product line.
Applications
- FTTH / PON distribution — one feeder serves 16 subscriber drops at an MDU, cabinet or distribution point; the second input takes a protection feeder from a diverse route.
- CATV and RF-video overlay — the 1550nm broadcast wavelength passes inside the same 1260-1650nm window, and SC/UPC matches legacy UPC video distribution plant.
- Enterprise and campus optical LAN — 16-way fiber distribution from a main equipment room where UPC jumper infrastructure is already installed.
- 1+1 feeder protection — primary and standby OLT feeds share one 16-port output array, so a feeder cut does not take down 16 subscribers.
For closures, distribution boxes and drop hardware around this splitter, see our FTTx supporting products.
How to Choose: 2×16 Configuration Guide
2×16 or 1×16? Choose 2×16 when a second feeder must reach the same 16 outputs — feeder protection or a second service source. Choose 1×16 for single-feed builds: 13.5/13.7dB budget instead of 14.4dB, one less input to manage.
UPC or APC? Match the polish already in the field. SC/UPC (blue) fits enterprise, legacy CATV and data-network plant. Many operator PON standards specify SC/APC (green); if that is your specification, order the APC variant.
Which package? The ABS box suits splice trays, wall boxes and ODFs — see the ABS box module range. Pick LGX for chassis headends, a steel-tube mini module for splice closures, or a rack panel for ODF frames.
Fiber diameter and lead length? 0.9mm pigtails stay inside protected trays; choose 2.0mm or 3.0mm jacketed leads where fibers route between enclosures. Standard length is 1m; custom lengths avoid excess slack.
Budget check. Start from the 14.4dB splitter loss, add connector pairs and splice points along each drop, and confirm the total against your OLT/ONU budget with the splitter loss chart (1×2 to 1×64).
2×16 SC/UPC ABS Box vs Sibling Models
For SC/APC splice-closure builds, the blockless mini module range covers dual-input steel-tube configurations.
Testing & Quality Control
Optical performance is verified against the parameters in the specification table above — insertion loss, uniformity, return loss, PDL, directivity and wavelength dependent loss. Compliance with Telcordia GR-1209-CORE and GR-1221-CORE is stated per BWNFiber product documentation.
Packaging & Ordering Information
Standard build: 2×16 split, SC/UPC, G657A fiber, 1m leads, 120×80×18mm ABS box; fiber diameter, lead length and connector mix customizable per order.
Request a Quote
Include these six parameters so we can price the exact build:
- Split configuration: 2×16 (or 1×16 / 2×32)
- Connector and polish: SC/UPC on this model; SC/LC/ST, APC/UPC available
- Fiber type: G657A standard, or specify your requirement
- Fiber diameter: 0.9mm, 2.0mm or 3.0mm
- Lead length: 1m standard, or custom
- Quantity and installation point (splice tray, distribution box, ODF)
Send it via the inquiry form on this page or our contact page; our team will reply with product details and pricing.