Cassette PLC Splitter

BWN-PLC-CT-2X64-SC-APC-2.0 2×64 SC/APC Cassette-Type PLC Splitter

A 2×64 cassette PLC splitter with SC/APC connectors on 2.0mm pigtails: two inputs and 64 outputs per path — 128 ports in one protected ABS module, for dual-PON or redundant-feed branches at maximum density. 21.0dB insertion loss, 2.2dB-class uniformity, 1260–1650nm, -40~+85°C.

2×64 Cassette PLC Splitter Overview

The BWN-PLC-CT-2X64-SC-APC-2.0 is the density ceiling of the cassette PLC family: a dual-input 2×64 planar splitter in one protected ABS module — two input ports, 64 outputs per path, 128 SC/APC-terminated ports in a single cassette. One module can run two PON services to the same 64-drop branch, or a main and standby feed, without a second splitter position.

That density comes with discipline. Published insertion loss for the 2×64 is 21.0dB with a 2.2dB-class uniformity window — the widest in the family. At this level the splitter alone consumes most of a GPON Class B+ budget (28dB); 2×64 builds typically assume higher-budget optics (Class C+) and a clean, short distribution plant. Verify the budget before the purchase order, not after. Family overview: cassette PLC splitter category.

Key Features

  • 128 ports in one cassette: two independent inputs, each split to 64 SC/APC outputs.
  • Dual-service or redundant-feed ready: GPON + XGS-PON coexistence or main/standby architectures in a single module.
  • Protected cassette format: ABS module for street cabinets, distribution boxes and high-density ODF panels.
  • Planar flatness: the 1260–1650nm band covers GPON, XGS-PON and NG-PON2 wavelength plans.
  • Wide temperature rating: -40°C to +85°C operating and storage.
  • Configurable at order: 1m / 2.0mm pigtails standard; 0.9mm, 3.0mm and custom lengths available.

Specifications — 2×64 Configuration

ParameterValue (this model)
ModelBWN-PLC-CT-2X64-SC-APC-2.0
Splitter TypePLC (planar lightwave circuit), cassette module
Configuration2 × 64 (dual input, 128 ports total)
ConnectorsSC/APC, inputs and outputs
Fiber Diameter2.0mm pigtails (0.9mm / 3.0mm options)
Fiber Length1m standard, customized on request
Fiber TypeG657A (customer-specified fiber available)
Operating Wavelength1260–1650nm
Insertion Loss≤ 21.0dB
Loss Uniformity≤ 2.2dB
Return Loss≥ 55dB (APC)
Polarization Dependent Loss≤ 0.4dB
Directivity≥ 55dB
Wavelength Dependent Loss≤ 0.5dB
Temperature Stability (-40~+85°C)≤ 0.5dB
Operating / Storage Temperature-40°C to +85°C
ComplianceTelcordia GR-1209-CORE, GR-1221-CORE (per BWNFiber product documentation)

2×N PLC Splitter Reference Table (Series Values)

Parameters2×22×42×82×162×322×64
Operating Wavelength (nm)1260~1650
Fiber TypeG657A or customer specified
Insertion Loss (dB)4.07.611.014.417.521.0
Loss Uniformity (dB)0.61.01.21.51.82.2
Return Loss (dB)555555555555
Polarization Dependent Loss (dB)0.20.20.30.30.40.4
Directivity (dB)555555555555
Wavelength Dependent Loss (dB)0.30.40.50.50.50.5
Temperature Stability (-40~85°C) (dB)0.40.40.40.50.50.5
Operating / Storage Temperature (°C)-40~+85

Values above are the published 2×N reference figures for the BWNFiber PLC series; this page is the 2×64 column. Confirm the cassette outline drawing against the current datasheet before ordering.

Connectors, Fiber Types & Compatibility

This model ships with SC/APC on both inputs and all 64 outputs per path. Fiber is G657A bend-insensitive singlemode standard; customer-specified fiber available. The 2.0mm jacketed pigtails (1m standard; 0.9mm and 3.0mm options) mate with SC adapter fields in cabinets, fiber distribution boxes and ODF frames.

At 128 ports per module, confirm the enclosure has the adapter capacity and slack management for two 64-port fields before ordering. The cassette is a protected component, not a sealed outdoor device.

Applications

  • Maximum-density FTTH distribution: 64 drops per service from a single cassette position.
  • GPON + XGS-PON coexistence at scale: two services on one passive branch without rebuilding the distribution point.
  • High-availability branches: main/standby feeders into the same 64 outputs.
  • Centralized-split ODN architectures: where the design consolidates splitting at one cabinet instead of cascading across the field.

How to Choose the Right Configuration

1. Budget gate first: 21.0dB IL + 2.2dB uniformity + fiber/connectors must fit your PON class budget. If the margin is thin, step down to 2×32 (17.5dB) or a 1×64 single-input. The splitter loss chart maps the ratios.

2. One service or two? One → 1×64. Two services or redundancy → this 2×64.

3. Topology: centralized 2×64 suits concentrated drops; geographically spread drops may be better served by cascaded smaller splits.

4. Polish and plant: APC end to end; confirm the distribution plant is SC/APC throughout.

5. Enclosure capacity: verify adapter count and slack management for 128 ports before specifying.

How This Model Differs from Its Neighbors

ModelPorts totalILUniformityBest for
This page: 2×64 cassette SC/APC12821.0dB2.2dBDual-service max density
2×32 cassette SC/APC6417.5dB1.8dBDual-service branches
1×64 cassette SC→LC6420.5/21.0dB2.0dBMax split, hybrid interface
2×8 cassette SC/APC1611.0dB1.2dBSmall dual-input splits

Family navigation: cassette PLC splitters · all PLC formats · FBT vs PLC comparison · splitter loss chart.

Testing & Quality Control

A 2×64 acceptance means 128 per-port IL measurements (two paths × 64 ports), plus the uniformity window and per-port RL. At a 2.2dB uniformity class, the worst port — not the average — decides whether the furthest subscriber syncs; insist on per-port records for project orders. The published characterization for this series is stated to Telcordia GR-1209-CORE / GR-1221-CORE generic requirements; share your acceptance criteria and we align shipment documentation accordingly.

Packaging & Ordering Information

  • Model: BWN-PLC-CT-2X64-SC-APC-2.0 (PLC · cassette module · 2×64 dual input · SC/APC · 2.0mm)
  • Standard supply: 2×64 split, SC/APC connectors, 2.0mm G657A pigtails, 1m length
  • Options on request: 0.9mm and 3.0mm pigtail jackets, custom lengths, customer-specified fiber
  • Packaging, MOQ and lead time are confirmed per order — send your quantity and destination for a written confirmation

Request a Quote for the 2×64 Cassette PLC Splitter

Send these six parameters for a configured quote:

  1. Split configuration (this page: 2×64, dual input)
  2. Service and wavelength plan (dual-PON / redundant feed)
  3. Loss budget context (PON class, approximate reach)
  4. Connector and polish (standard: SC/APC)
  5. Pigtail diameter and length (standard 2.0mm / 1m)
  6. Quantity and destination

Contact the BWNFiber team or use the inquiry form on this page for pricing, datasheets, and samples.

FAQ

BWN-PLC-CT-2X64-SC-APC-2.0 2×64 SC/APC Cassette-Type PLC Splitter FAQ

What is a 2×64 cassette PLC splitter?

A planar lightwave circuit splitter with two inputs and 64 outputs per path — 128 ports in one protected ABS cassette. Each input splits across all 64 outputs, so one module carries two PON services or a redundant feed to a full 64-drop branch.

What is the insertion loss of the 2×64?

The published figure is 21.0dB with a 2.2dB-class uniformity window. That consumes most of a GPON Class B+ 28dB budget once fiber and connectors are added — 2×64 builds typically specify higher-budget optics such as Class C+. Verify before ordering.

What are the two inputs for?

Dual-PON service (GPON on one input, XGS-PON on the other, both reaching the same 64 drops) or a main/standby feeder pair. If your branch carries one service, the 1×64 is the simpler choice.

2×64 vs 1×64 — which should I specify?

Same 64 outputs per service. The 2×64 adds the second input path for dual-service or redundancy architectures; the 1×64 is single-service. Both sit around 21dB IL, so the decision is architectural, not optical.

Does uniformity matter at 64 ports?

Yes, more than at low ratios. A 2.2dB-class uniformity window means the worst port can sit about 2dB above the best; at 64 ports with a tight budget, that worst port decides whether the furthest subscriber syncs. Acceptance should record per-port IL, not averages.

Can this cassette be installed outdoors?

Only inside a sealed cabinet, distribution box or closure. Also confirm the enclosure hosts 128 SC adapters plus slack management before specifying this density. The module itself is rated -40°C to +85°C.

What pigtail options are available?

2.0mm jacketed pigtails at 1m standard; 0.9mm and 3.0mm constructions and custom lengths on request.

Do you support OEM and project volumes?

Yes. Send split configuration, connector polish, pigtail spec, quantity and destination; we confirm the build on a datasheet and quote project pricing.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.