Overview
The BWN-PLC-CT-2.0 is a 2×4 cassette-type PLC (planar lightwave circuit) splitter with SC/APC connectors. It accepts two input fibers and distributes the optical signal evenly across four output ports over the full 1260–1650nm wavelength range, with 7.6dB maximum insertion loss. It is built for FTTH and PON distribution points that need to serve four subscribers from one or two feeder fibers without active electronics.
Specify this configuration for dual-input redundancy or two PON services on one distribution point, in enclosures with cassette slots rather than splice-only space. The module measures 100×80×10mm, terminates in SC/APC adapters, and ships with 2.0mm pigtails at 1m standard length. Single-feeder jobs fit a 1×4 cassette; SC/UPC plants and LGX chassis have sibling models compared below. For the full family, see the PLC splitter category and the cassette PLC splitter category.
Key Features
- 2×4 split in one device — two inputs × four outputs; a main feeder plus a protection or second-service feeder reach the same four drops without a second splitter.
- 7.6dB maximum insertion loss — only 0.5dB above a single-input 1×4 (7.1dB, P grade), so dual input costs almost no power budget.
- 55dB return loss with APC polish — the 8° angled endface keeps reflectance away from PON OLT lasers and 1550nm RF video overlay.
- ≤1.0dB loss uniformity — the four outputs stay within 1dB of each other, so ONU receive levels stay even.
- -40~+85°C operating range, ≤0.4dB temperature stability — rated for outdoor cabinets and unconditioned boxes.
- 100×80×10mm cassette housing — plugs into standard ODF and distribution box cassette slots; internal PLC device 50×4×4mm.
- 1260–1650nm operating window — transparent to 1310/1490/1550nm PON wavelengths and CATV overlay.
Specifications
| Parameter | Value |
|---|
| Model | BWN-PLC-CT-2.0-2X4-SC-APC |
| Split configuration | 2×4 (2 inputs × 4 outputs) |
| Package | PLC cassette type; module 100×80×10mm; internal device 50×4×4mm |
| Connector | SC/APC on this build; SC/LC/ST with APC or UPC available |
| Operating wavelength | 1260~1650nm |
| Insertion loss (max) | ≤7.6dB |
| Loss uniformity (max) | ≤1.0dB |
| Return loss (min) | ≥55dB |
| Polarization dependent loss (max) | ≤0.3dB |
| Directivity (min) | ≥55dB |
| Wavelength dependent loss (max) | ≤0.4dB |
| Temperature stability, -40~+85°C (max) | ≤0.4dB |
| Fiber type | G657A or customer specified |
| Pigtail diameter | 2.0mm on this build; 0.9mm / 3.0mm available |
| Pigtail length | 1m or customized |
| Operating / storage temperature | -40~+85°C |
| Compliance | Telcordia GR-1209-CORE and GR-1221-CORE, per BWNFiber product documentation |
For adjacent split ratios in the same 2×N family: 2×2 is ≤4dB, 2×8 is ≤11dB, 2×16 is ≤14.4dB and 2×32 is ≤17.5dB insertion loss. See the splitter loss chart (1×2 to 1×64) for the full table.
Connectors, Fiber Types & Compatibility
This build terminates in SC/APC connectors (green housing, 8° angled polish); SC, LC or ST in APC or UPC can be ordered. Fiber is G657A bend-insensitive or customer specified. The 2.0mm pigtail balances mechanical protection against routing space in distribution boxes; 0.9mm and 3.0mm are available.
The cassette plugs into the cassette slot of an ODF frame or fiber distribution box and presents its ports on an SC adapter plate — no splicing to install or replace. For an existing chassis, confirm the slot accepts a 100×80×10mm module. Mate APC ports only with APC cords; mating APC to UPC/PC damages the endface and adds loss.
Applications
- FTTH distribution points for small MDUs — one cassette serves four units; the second input is a protection feeder or a second service.
- PON segments with dual-homed feeders — main and backup OLT feeders land on the same splitter, so a feeder cut does not take down the segment.
- PON plus CATV/RF video overlay — the 1260–1650nm window passes 1310/1490nm data and 1550nm video; APC polish keeps reflectance low.
- Rural and short-reach fiber distribution boxes — four drops per cassette; a failed unit is swapped from the slot without re-splicing.
- Two-service delivery at business parks — separate service feeds share one compact module instead of two single-input splitters.
For enclosure, closure and drop-cable hardware, see our FTTx supporting products.
How to Choose: Split Ratio, Package and Polish
1×4 or 2×4? One feeder at the distribution point → 1×4 cassette. Choose 2×4 when you need a second input for redundancy or a second service — the penalty is only 0.5dB (7.6dB vs 7.1dB P grade).
Cassette, blockless or LGX? Cassettes plug into ODF/FDB slots and present adapters up front — fastest to install and replace. Blockless steel-tube splitters are spliced inside closures. LGX modules fit standard rack-mount LGX chassis. Match the package to the enclosure.
APC or UPC? PON, FTTH and CATV plants standardize on APC for its higher return loss (≥55dB here). If your plant is UPC throughout, use the SC/UPC sibling below rather than mixing polishes on one link.
Budget check. In a Class B+ GPON budget of about 28dB, a 2×4 split takes ≤7.6dB, wavelength/temperature variation adds ≤0.8dB, and connector pairs take 2–3dB — leaving roughly 17dB for fiber and splices, enough for several kilometers. Verify your OLT/ONU classes against the splitter loss chart before finalizing.
2×4 Cassette SC/APC vs Sibling Models
| Model | Package | Polish | Choose when |
|---|
| BWN-PLC-CT-2.0-2X4-SC-APC (this page) | Cassette, 100×80×10mm | SC/APC | ODF/FDB cassette slots on a PON/FTTH plant |
| BWN-PLC-IM-2X4-SC-UPC insertion module | Insertion ABS module | SC/UPC | UPC-standardized plants, box/tray mounting |
| BWN-PLC-IM-2X4-SC-APC LGX | LGX module | SC/APC | Standard LGX rack chassis in central offices or racks |
All three share the same 2×4 optical core (≤7.6dB IL, ≥55dB RL on APC builds) — the choice is mechanical and polish, not performance. For splice-in steel-tube formats see the blockless mini PLC splitter category; for concept background see the fiber optic splitter overview.
Testing & Quality Control
Optical performance is verified against the parameters in the specification table — insertion loss, uniformity, return loss, PDL, directivity and wavelength dependent loss. Compliance with Telcordia GR-1209-CORE and GR-1221-CORE is stated per BWNFiber product documentation.
Packaging & Ordering Information
Standard configuration: 2×4 cassette, SC/APC, G657A fiber, 2.0mm pigtails, 1m length. Pigtail diameter and length, connector type and polish are customizable per the specification table. Confirm scheduling with the sales team at inquiry.
Request a Quote
Include these six items when requesting a quote:
- Split configuration (2×4) and quantity
- Package (cassette, 100×80×10mm module)
- Connector and polish (SC/APC standard; SC/LC/ST, APC/UPC options)
- Fiber type (G657A standard or customer specified)
- Pigtail diameter and length (2.0mm / 1m standard; 0.9mm, 3.0mm and custom lengths available)
- Test report or documentation requirements
Send it via the inquiry form on this page or contact the BWNFiber team — we will reply with details and pricing.
“`
—