ADSS-nB1.3
ADSS-nB1.3 48F / 72F / 96F G.652.D 200m Span Aerial Fiber Optic Cable
ADSS-nB1.3 48F / 72F / 96F G.652.D 200m Span Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 48F / 72F / 96F. Specify span and fiber count against the source drawing.

Product summary
The BWNFiber ADSS-nB1.3 configuration covers 48F, 72F and 96F G.652.D2 fiber counts for a supplied 200 m span designation. The source record lists a PE outer sheath, aramid-yarn strength member and swellable tape and yarn for water blocking. The supplied drawing record also contains an HDPE label; confirm the intended sheath grade before quotation or publication.
For broad selection, see ADSS outdoor fiber optic cables. The public 72F G.652.D 200 m model and 96F G.652.D 200 m model must be checked for canonical ownership and corrected configuration copy before this family page is considered independent.
The 200 m designation is a design input, not a universal route approval. Confirm every span, wind and ice case, temperature, sag, clearance, attachment position and compatible hardware with the project engineer or route owner.
Quick configuration answer
Choose one fiber-count row first. The 48F, 72F and 96F rows have different tube plans, dimensions and weights, while the supplied table lists the same 2,500 N maximum allowed tensile value and 1,000 N/100 mm crush resistance for each row. Do not combine mechanical values from different rows in an RFQ.
Key features from the supplied record
- Model: ADSS-nB1.3
- Fiber counts: 48F, 72F or 96F
- Fiber grade: G.652.D2
- Span designation: 200 m
- Strength member: aramid yarn
- Water blocking: swellable tape and yarn
- Outer sheath: TBC — PE is stated in the source tables; an HDPE label appears in the supplied drawing record
- Connectors/interfaces: not applicable to the supplied bulk aerial-cable record; termination and hardware are TBC
Configuration and technical data
| Parameter | 48F | 72F | 96F |
|---|---|---|---|
| Fibers per tube | 8 | 12 | 12 |
| Tubes + fillers | 6 + 0 | 6 + 0 | 8 + 0 |
| Loose-tube size (mm) | 2.0 | 2.1 | 2.1 |
| FRP/after-PE coating (mm) | 2.0 | 2.2 | 3.5 |
| Sheath thickness (mm) | 1.5 | 1.6 | 1.6 |
| Cable diameter (mm) | 9.5 | 10.5 | 11.5 |
| Cable weight (kg/km) | 68 | 80 | 102 |
| Maximum allowed tensile (N) | 2,500 | 2,500 | 2,500 |
| Crush resistance (N/100 mm) | 1,000 | 1,000 | 1,000 |
| Static bend radius | 10 × cable diameter | 10 × cable diameter | 10 × cable diameter |
| Dynamic bend radius | 20 × cable diameter | 20 × cable diameter | 20 × cable diameter |
Engineering hold: The supplied V4 file identifies the source table as complex and requiring alignment review. Reconfirm every cell against the controlled drawing before publishing.
Optical characteristics in the supplied record
| Parameter | Listed value |
|---|---|
| Mode-field diameter at 1310 nm | 9.2 ± 0.4 μm |
| Cladding diameter | 125 ± 1 μm |
| Cable cut-off wavelength | ≤1260 nm |
| Attenuation at 1310 nm | ≤0.36 dB/km (max.) |
| Attenuation at 1550 nm | ≤0.21 dB/km (max.) |
| Chromatic dispersion, 1288–1339 nm | ≤3.5 ps/nm·km |
| Chromatic dispersion at 1550 nm | ≤17 ps/nm·km |
| Macro-bending loss, 60 mm diameter, 100 turns at 1550 nm | ≤0.1 dB |
These values are transcribed from the supplied record. Confirm whether each limit is for the fiber, finished cable, or a specified test condition before treating it as an acceptance requirement.
Environmental values in the supplied record
- Operation: −30 °C to +60 °C
- Installation: −30 °C to +60 °C
- Storage: −40 °C to +70 °C
The applicable test method, load severity, altitude, UV, pollution and electrical-field conditions are TBC. These ranges do not replace a route-specific ADSS design review.
How to select the correct configuration
- Confirm that the route requires an all-dielectric, self-supporting aerial cable.
- Select 48F, 72F or 96F from the required working capacity and reserve.
- Keep the selected row’s tube plan, diameter, weight and mechanical values together.
- Confirm the sheath grade (PE or HDPE) against the controlled drawing and electrical/environmental assessment.
- Provide every span, wind, ice, temperature, sag, clearance, attachment position and hardware requirement for route review.
- Request the controlled datasheet, drawing, calculation basis, test scope and revision identifier before purchase-order release.
Compatibility and application boundary
This record is for bulk ADSS aerial cable. Connector type, termination, suspension/dead-end fittings, vibration control, route angle, electrical-field suitability and hardware compatibility are not established by the supplied page and must be confirmed separately. “All-dielectric” does not approve every energized line, voltage, attachment position or span.
Testing and quality-control evidence
The supplied record lists optical, mechanical and temperature values but does not provide a complete test method, equipment, sampling plan, acceptance criterion, certificate or routine-test report. Request those documents for the ordered configuration. Do not use a generic standard logo or another model’s report as proof.
Packaging and procurement
The supplied record does not confirm drum length, reel type, packaging, MOQ, price, inventory, lead time, warranty or delivery terms. Mark these fields TBC — source required until confirmed in the controlled quotation.
RFQ checklist
State:
- ADSS-nB1.3 and selected count: 48F, 72F or 96F
- G.652.D2 fiber grade and 200 m span designation
- Confirmed sheath grade and source revision
- Total cable length, length per drum/roll and quantity
- Cable marking, packaging and delivery destination
- Route drawing/pole schedule, every span, wind/ice/temperature and clearances
- Required hardware, test records, drawing and acceptance documents
CTA
Request an ADSS-nB1.3 configuration review. Send the selected fiber count, route/span schedule, environmental load basis, sheath requirement, total length, drum plan and required evidence. BWNFiber should confirm the exact model and controlled revision before quotation or engineering use.
Use the verified BWNFiber contact/RFQ path after the page owner confirms the final destination and form mapping.
Image and schema handoff
- Retain the supplied product image; do not generate a replacement.
- Suggested alt:
ADSS-nB1.3 48F, 72F and 96F G.652.D2 aerial fiber optic cable for a 200 m span designation. - Product, BreadcrumbList and visible FAQ schema are recommendations only after canonical/model confirmation and a check for duplicate Yoast output. No offers, price, stock, reviews, ratings, certifications or unsupported test/image claims.
FAQ
Does the 200 m designation approve every 200 m route?
No. It is the supplied design designation. Route approval still requires span-by-span load, sag, clearance, attachment, environmental and hardware review.
Which fiber counts are covered?
The supplied configuration covers 48F, 72F and 96F G.652.D2. Select one row before comparing diameter, weight, tube plan and mechanical values.
Is the outer sheath PE or HDPE?
The source tables state PE, while the supplied drawing record contains an HDPE label. This is unresolved and must be confirmed before ordering or publication.
Are connectors included?
No connector option is established in the supplied bulk-cable record. Termination and hardware scope are TBC and should be stated in the RFQ.
What should be compared between quotations?
Compare the same fiber count, tube plan, sheath, diameter, weight, mechanical basis, route-load assumptions, hardware scope, test evidence, drum plan and delivery scope.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.