ADSS Cable

ADSS 8F / 12F / 24F / 48F Single-Sheath Self-Supporting Fiber Optic Cable

ADSS 8F / 12F / 24F / 48F Single-Sheath Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 8F / 12F / 24F / 48F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS

Product summary

This BWNFiber product record covers 8F, 12F, 24F and 48F single-sheath ADSS cable configurations for self-supporting aerial fiber routes. The supplied options are SM G.652.D, MM 50/125 and MM 62.5/125, with a PE outer sheath. Choose one complete fiber-count and fiber-type configuration before requesting a quotation; do not combine mechanical or optical values from different alternatives.

The source record designates a 100 m span. That designation is not approval for every 100 m route. A final aerial design still needs the surveyed span and ruling span, wind/ice conditions where applicable, sag and clearance limits, attachment position, installation method and compatible hardware. TBC — route basis and engineering approval are required.

Key features and boundaries

  • Fiber-count options: 8F, 12F, 24F and 48F
  • Fiber options listed in the source: SM G.652.D, MM 50/125 and MM 62.5/125
  • Outer jacket/sheath listed: PE
  • Loose-tube and filler material listed: PBT
  • Central strength member listed: FRP, 1.6 ± 0.2 mm
  • Moisture barrier listed: water-blocking yarn
  • Reinforcement listed: “Kelver yarn” in the source; confirm whether the controlled specification uses “aramid yarn”
  • Application stated in the source: self-supporting aerial fiber routes
  • Standards, certification, test reports, compatible hardware and route load case: TBC — source required

Configuration and construction

Fiber countTube countFibers per tubeFiber type options in sourceJacket
8F18 F/tubeOS1, OS2, OM1, OM2, OM3, OM4PE
12F112 F/tubeOS1, OS2, OM1, OM2, OM3, OM4PE
24F212 F/tubeOS1, OS2, OM1, OM2, OM3, OM4PE
48F412 F/tubeOS1, OS2, OM1, OM2, OM3, OM4PE

The source presents both formal fiber-grade labels (SM G.652.D / MM 50/125 / MM 62.5/125) and the OS/OM labels above. Engineering should confirm the permitted pairing for each sellable configuration before publication.

Construction parameterSupplied valueRelease status
Outer sheath materialPEQualified source value
Outer sheath diameter9.2 ± 0.5 mmEngineering/table review required
Loose tube/filler materialPBTEngineering/table review required
Loose tube/filler diameter2.0 ± 0.2 mmEngineering/table review required
Central strength memberFRPEngineering/table review required
Central strength member diameter1.6 ± 0.2 mmEngineering/table review required
Moisture barrierWater-blocking yarnSource wording retained
Reinforcement“Kelver yarn”Confirm controlled material name
Cable weight85.0 kg/km for 8/12/24/48 core in sourceConfirm whether one value applies to every count

Optical characteristics

Fiber optionWavelengthSupplied attenuation
SM G.652.D1310 nm / 1550 nm≤0.36 / 0.23 dB/km
MM 50/125850 nm / 1300 nm≤3.0 / 1.0 dB/km
MM 62.5/125850 nm / 1300 nm≤3.0 / 1.0 dB/km

These are supplied source values, not a finished-cable acceptance report. Confirm fiber grade, measurement method, temperature/condition, sample identity and whether the limits are fiber-level or cable-level before using them in a bid or link budget. The source review also flags dispersion, PMD and numerical-aperture rows for unit/condition review; those rows are intentionally withheld here.

Mechanical and environmental values

Parameter / conditionSupplied valueRelease status
Span designation100 mNot route approval; load case required
Installation temperature-15 to +60 °CConfirm controlled source
Operation and transport temperature-40 to +70 °CConfirm controlled source
Minimum bend radius, long term10DSource value; engineering review required
Minimum bend radius, short term20DSource value; engineering review required
Crush load, long term2,000 N/100 mmConfirm test condition
Crush load, short term3,000 N/100 mmConfirm test condition

The source review separately records an allowable-tensile-strength conflict (1,500 N long term versus 800 N short term). Those tensile values are not reproduced as product claims until engineering resolves the condition and source-row mapping. Do not relabel any supplied value as RTS, MAT or a project safety limit without the controlled specification.

How to select the correct configuration

  1. Select the required fiber count and the approved fiber grade.
  2. Keep the count, tube plan, fiber-per-tube value, jacket and source dimensions together.
  3. Confirm the route basis: actual spans, ruling span, wind/ice conditions, sag, clearance, attachment position and installation method.
  4. Ask for the controlled drawing, approved material wording, test schedule and compatible suspension/dead-end hardware.
  5. Request one complete quotation row; do not merge alternatives from different fiber-count or fiber-type rows.

Application and compatibility boundary

This record is for self-supporting aerial fiber routes. It does not establish suitability for duct, direct-buried, indoor, armored or FTTH drop deployments. ADSS construction alone does not approve a utility voltage, pole attachment or hardware set. The route owner or qualified engineer must approve the installed system.

For broad span, sag, wind/ice and route selection guidance, use the confirmed ADSS outdoor cable category rather than turning this exact product page into a general ADSS guide. For a related single-sheath record, review the single-sheath ADSS model page only after the URL register confirms distinct ownership. The ADSS versus OPGW project guide is the appropriate place for comparison intent. For an exact configuration request, use the BWNFiber contact page after its form and destination are verified.

Packaging and RFQ information

The supplied packing record lists a 2 km standard drum length. Request confirmation for the selected configuration and destination. Include:

  • selected fiber count and fiber grade;
  • total cable length and required length per drum/roll;
  • quantity and standard/custom drum plan;
  • cable marking text and delivery destination;
  • route/span and load inputs;
  • required drawing, test-record and inspection documents; and
  • any packaging, labeling or commercial requirements that must be quoted.

Documents and quality control

  • Controlled datasheet: TBC — source required
  • Cross-section/dimensional drawing: TBC — source required
  • Product-specific test report: TBC — source required
  • Standards/certification statement: TBC — source required
  • Route-specific sag/tension calculation: Project-specific; not supplied

Do not use a competitor datasheet or a general standard citation as proof that this exact BWNFiber configuration passed a test. The document revision, sample/configuration identity, method, condition and acceptance limit must be traceable.

Request an ADSS configuration review

Send the selected fiber count, fiber grade, route/span schedule, total length, drum requirement, marking text and destination. Ask BWNFiber to confirm the controlled datasheet, drawing, test-document schedule, material terminology and unresolved mechanical/optical fields before purchase-order release.

FAQ

Frequently asked questions

Which fiber counts does this product record cover?
8F, 12F, 24F and 48F.

Which fiber options are listed?
SM G.652.D, MM 50/125 and MM 62.5/125 are listed as alternatives. Confirm the approved pairing for the exact sellable configuration.

Does 100 m mean the cable is approved for every 100 m aerial span?
No. It is a product designation in the supplied record. Route approval also needs load, sag, clearance, attachment and hardware inputs.

What jacket is listed?
PE is listed. LSZH is not supported by this source and should not be added to the page.

What construction materials are listed?
PBT loose tube/filler elements, FRP central strength member, PE outer sheath, water-blocking yarn and “Kelver yarn” reinforcement are listed. Confirm the controlled material terminology before release.

What is the supplied outer diameter?
The source lists 9.2 ± 0.5 mm. Confirm the dimensional row and measurement basis.

What weight is listed?
The source lists 85.0 kg/km for 8/12/24/48 core. Confirm whether the same value applies to every count.

What attenuation values are supplied?
SM G.652.D: ≤0.36/0.23 dB/km at 1310/1550 nm; MM 50/125 and MM 62.5/125: ≤3.0/1.0 dB/km at 850/1300 nm. These require test-basis confirmation.

What bend radius applies?
The visible source lists 10D long term and 20D short term. Because the source review flags engineering inconsistencies, confirm which condition governs before installation or publication.

Can I use the tensile and crush rows as route design limits?
No. The visible source does not provide a complete controlled load/test basis, and the tensile values are explicitly held for engineering review.

What should I send for an accurate quotation?
Send the selected count and fiber grade, total and drum lengths, quantity, marking, destination, route/span inputs, required documents and any hardware or packaging requirements.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.