ADSS-80M
ADSS-80M 12F / 24F / 48F / 96F / 144F Self-Supporting Aerial Fiber Optic Cable
ADSS-80M 12F / 24F / 48F / 96F / 144F Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F / 24F / 48F / 96F / 144F. Specify span and fiber count against the source drawing.

Product summary
The BWNFiber ADSS-80M product record covers 12F, 24F, 48F, 96F and 144F configurations with HDPE outer sheathing. The supplied table pairs each fiber count with its cable diameter, weight, maximum allowed tensile value, crush resistance and bend-radius limits. Select one complete row for quotation; do not combine values from different fiber-count rows.
The “80M” designation identifies this product record. It is not, by itself, approval for every 80 m aerial route. Final suitability depends on the surveyed spans, wind and ice loads, temperature, sag, clearances, attachment position and compatible suspension/dead-end hardware. TBC — BWNFiber engineering must confirm the exact span basis and route conditions.
Key verified fields
- Fiber-count options: 12F, 24F, 48F, 96F and 144F
- Outer jacket: HDPE
- Strength-related material listed in the supplied record: aramid yarn
- Water-blocking material listed in the supplied record: swellable tape and yarn
- Application stated in the record: self-supporting aerial fiber routes
- Fiber grade, central strength-member construction, applicable standards, test methods and hardware: TBC — source required
Configuration and mechanical specifications
| Fiber count | Fibers/tube | Tubes + fillers | Tube size (mm) | Cable diameter (mm) | Weight (kg/km) | Max allowed tensile (N) | Crush (N/100 mm) |
|---|---|---|---|---|---|---|---|
| 12F | 6 | 2 + 4 | 1.8 | 9.0 | 62 | 1,200 | 2,200 |
| 24F | 6 | 2 + 4 | 1.8 | 9.0 | 62 | 1,200 | 2,200 |
| 48F | 12 | 4 + 2 | 2.1 | 9.8 | 72 | 1,600 | 2,200 |
| 96F | 12 | 8 + 0 | 2.1 | 11.4 | 101 | 1,800 | 2,200 |
| 144F | 12 | 12 + 0 | 2.1 | 14.4 | 160 | 2,400 | 2,200 |
Bend limits in the supplied record: static minimum bend radius = 10 × cable diameter; dynamic minimum bend radius = 20 × cable diameter. Use the exact approved datasheet and installation method for field work.
Optical and environmental values in the supplied record
The record lists mode-field diameter at 1310 nm as 9.2 ± 0.4 μm, cladding diameter as 125 ± 1 μm, attenuation as ≤0.36 dB/km at 1310 nm and ≤0.21 dB/km at 1550 nm, and macro-bending loss of ≤0.1 dB under the stated 1550 nm condition. It also lists operating and installation temperatures of −30°C to +60°C and storage temperature of −40°C to +70°C.
These values are reproduced for source review. The page must not describe them as a project acceptance result until BWNFiber confirms the fiber grade, whether each value is fiber-level or finished-cable-level, the test method, sample identity and applicable acceptance limits.
How to choose the correct configuration
- Select the required working, spare and future-capacity fiber count.
- Use one complete row to carry diameter, weight, tensile value and tube plan into the RFQ.
- Provide every span, the ruling span, wind/ice and temperature basis, clearances and attachment position.
- Confirm the central strength member, sheath construction, fiber grade and hardware against the controlled datasheet.
- Request the drawing, route calculation inputs, test/document schedule and drum plan before purchase-order release.
Compatibility and application boundary
This record is for self-supporting aerial routes. It does not establish suitability for underground, duct, direct-buried, FTTH drop, armored or indoor/data-center applications. ADSS construction alone does not approve a particular utility voltage, attachment position or route. The route owner or qualified engineer must approve the installed system.
RFQ checklist
State the selected fiber count, total length, length per drum/roll, quantity, cable marking, delivery destination, fiber grade, required jacket, route span/load information, hardware scope, required drawings, test records, packaging and Incoterm. Ask BWNFiber to identify any deviation from the supplied row and to confirm the controlling document revision.
Documents
- Source DOCX/PDF: TBC — link only after product-owner approval
- Cross-section/drawing: TBC — source required
- Test report: TBC — source required
- Route-specific sag/tension calculation: Project-specific; not supplied
Primary CTA
Request an ADSS-80M configuration review — send the selected fiber count, route/span schedule, load conditions, required length per drum, quantity and destination. Ask for the controlled datasheet, drawing and document/test schedule before approving the quotation.
FAQ
What fiber counts are available? The supplied record lists 12F, 24F, 48F, 96F and 144F. Select one row and keep its values together.
Does ADSS-80M guarantee an 80 m installation span? No. The product name is not a route approval. Span suitability requires the actual load case, sag, clearances, attachment position and hardware review.
What jacket is listed? HDPE is listed for the outer jacket/sheath. Confirm the exact sheath construction in the controlled datasheet.
What are the cable diameters? The supplied rows list 9.0 mm, 9.8 mm, 11.4 mm and 14.4 mm, paired to the five fiber-count options above.
What tensile values are listed? The source table lists 1,200 N for 12F/24F, 1,600 N for 48F, 1,800 N for 96F and 2,400 N for 144F. The source label is “max allowed tensile”; do not relabel it as RTS or MAT without confirmation.
What bend radius should installers use? The supplied record lists 10 × cable diameter static and 20 × cable diameter dynamic. The approved installation method and datasheet control field use.
What fiber grade is used? The visible page does not safely confirm it. TBC — source required. Do not infer G.652.D from the image filename.
Is this cable suitable near power lines? ADSS is an aerial self-supporting product category, but this record does not approve a voltage, attachment position or electrical environment. Obtain route-owner/engineering approval.
What should a quotation include? Fiber count, total and drum lengths, quantity, marking, destination, route/load inputs, exact construction, hardware, drawings, test evidence and commercial terms.
Can values from two rows be combined? No. Quote one complete configuration row.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.