ADSS Cable

ADSS 72F G.652.D 200m Span 12.5mm Self-Supporting Fiber Optic Cable

ADSS 72F G.652.D 200m Span 12.5mm Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 72F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS

Product answer

The supplied BWNFiber record describes a 72F G.652.D2 ADSS cable configuration with a listed 200 m span designation, HDPE outer sheath and 12.5 ± 0.5 mm outer diameter. The construction table lists six PBT loose tubes, an FRP central strength member, aramid-yarn strength material and a water-blocking system.

The 200 m designation is a product/design input, not approval for every 200 m aerial route. The route owner or qualified engineer must check the actual spans, wind, ice, temperature, sag-tension basis, clearances, attachment position and compatible hardware. The supplied source is marked Revise; PMD units and minimum bend-radius rows require confirmation before publication or order release.

Configuration summary

FieldSupplied recordRelease status
Fiber count72F / 72 fibersSupported by supplied V4; confirm approved revision
Fiber typeG.652.D2TBC — confirm approved nomenclature and fiber row
Listed span200 mSupported as record designation; not universal route approval
Outer sheathHDPE, blackTBC — confirm exact ordered jacket/material row
Outer diameter12.5 ± 0.5 mmSupported by supplied V4; confirm finished-cable row
Loose tubes6Conditional; verify source-row alignment
Fibers per tube12 (inferred from 72F / 6 tubes)TBC — source required; do not use for order release inference until confirmed
Loose-tube materialPBTConditional; verify source row
Central strength memberFRPConditional; engineering terminology check
Strength materialKevlar yarnConditional; confirm whether this is the approved term for the row
Moisture protectionJelly in loose tube; water-blocking yarn and gel listedConditional; confirm layer assignment
Connector/interfaceNot listed; bulk outdoor cableDo not infer pre-termination; splice/termination plan TBC

Key features

  • 72-fiber ADSS configuration for a listed 200 m span design input.
  • G.652.D2 fiber designation in the supplied record; final nomenclature requires source confirmation.
  • 12.5 ± 0.5 mm listed outer diameter with a black HDPE outer sheath.
  • Six loose tubes and PBT tube material listed in the construction table; exact row alignment requires review.
  • FRP central member and aramid-yarn strength material listed in the supplied record.
  • Optical and mechanical values are shown only with their wavelength, unit and condition; unresolved PMD and bend-radius rows remain TBC.

Cable construction

Component / parameterConditionValueEvidence status
Fiber countFinished cable72FSupplied V4
Loose tubesFinished cable6Supplied V4; source-row check
Loose tube materialTubePBTSupplied V4; source-row check
Central strength memberCable coreFRPSupplied V4; engineering check
Strength member materialCable coreKevlar yarnSupplied V4; terminology check
Filling compoundLoose tubeJellySupplied V4; layer check
Moisture barrierCableWater-blocking yarn and gelSupplied V4; layer check
Inner sheathMaterial / color / diameterPE / black / 8.2 ± 0.2 mmSupplied V4; confirm table alignment
Outer sheathMaterial / color / diameterHDPE / black / 12.5 ± 0.5 mmSupplied V4; confirm finished-cable row

Optical characteristics

Publish these values only after the approved source owner confirms that the rows belong to this exact G.652.D2 configuration.

Parameter / conditionListed valueRelease status
Attenuation @ 1310 nm≤0.36 dB/kmConditional source confirmation
Attenuation @ 1550 nm≤0.25 dB/kmConditional source confirmation
Attenuation difference @ 1285–1330 nm≤0.03 dB/kmConditional source confirmation
Attenuation difference @ 1525–1575 nm≤0.02 dB/kmConditional source confirmation
Zero-dispersion wavelength1312 ± 10 nmConditional source confirmation
Zero-dispersion slope≤0.090 ps/nm²·kmConditional source confirmation
Cable cutoff wavelength≤1260 nmConditional source confirmation
MFD @ 1310 nm9.2 ± 0.4 μmConditional source confirmation
MFD @ 1550 nm10.4 ± 0.5 μmConditional source confirmation
Effective group index @ 1310 nm1.466Conditional source confirmation
Effective group index @ 1550 nm1.467Conditional source confirmation
Point discontinuity @ 1310 / 1550 nm≤0.05 dBConditional source confirmation
Cladding diameter124.8 ± 0.7 μmConditional source confirmation
Cladding non-circularity≤0.7%Conditional source confirmation
Coating diameter254 ± 5 μmConditional source confirmation
Coating-cladding concentricity error≤12.0 μmConditional source confirmation
Coating non-circularity≤6.0%Conditional source confirmation
Core-cladding concentricity error≤0.5 μmConditional source confirmation
Curl radius≥4 mConditional source confirmation
PMD maximum individual fiber≤0.2 unit TBCdo not use for order release until unit is confirmed
PMD link design value (M=20, Q=0.01%)≤0.1 unit TBCdo not use for order release until unit is confirmed
PMD typical value0.04 unit TBCdo not use for order release until unit is confirmed

These optical values are not a complete link-loss budget. Connector, splice, design-margin and route losses must be assessed separately.

Mechanical and environmental data

Parameter / conditionListed valueRelease status
Listed span200 mRecord designation; route approval remains project-specific
Tensile load4000 NConfirm duration and test condition
Crush load2200 N / 100 mmConfirm duration and test condition
Installation temperature-30 to +70 °CConfirm source wording
Operation and transport temperature-40 to +70 °CConfirm whether storage is separate
Storage / transportation-40 to +75 °CConfirm source wording and precedence
Minimum bend radius, long term15DBlocked: conflicts with short-term row in supplied review
Minimum bend radius, short term10DBlocked: engineering review required

Do not invert, merge or choose between the two bend-radius values without the approved engineering source. A listed span or tensile row is not a route permit.

Fiber, jacket and interface boundaries

The page is for a bulk outdoor ADSS cable record. No connector, gender, polarity, end-face or factory termination is specified in the supplied V4. Treat termination, splice closure, pigtail and hardware selection as a separate project decision. Do not infer electrical tracking resistance, fire classification, UV rating, certification or compatibility from the words HDPE, PE or ADSS alone.

Before quotation, select one approved fiber grade/nomenclature and one exact jacket row. Do not combine values from alternative fiber or sheath rows.

How to validate the 200 m route design

Use the product record as one input to a route review. Confirm:

  1. Maximum and ruling spans, route angles and reserve requirements.
  2. Wind, ice, temperature, sag-tension and clearance assumptions.
  3. Attachment position, pole/tower geometry and hardware interface.
  4. Exact cable diameter, weight, sheath and approved mechanical values.
  5. The source-document revision and project acceptance limits.

The broad ADSS cable selection page should own the general span/load selection task. This page should own the exact 72F/G.652.D2/12.5 mm record.

Differences from related configurations

  • This page: 72F, listed G.652.D2, 200 m, 12.5 ± 0.5 mm; exact source confirmation required.
  • 96F G.652.D 200 m OD14.0 mm: a different fiber-count and diameter configuration; do not transfer its specifications here.
  • 48F G.652.D 120 m OD12.5 mm: a different fiber-count and span configuration; use it only as a related product link when its URL is confirmed.
  • ADSS category page: broad route, load and hardware selection; it is not a substitute for this exact product record.

RFQ information

Send the following for a comparable quotation:

  • Exact product designation and confirmed model/SKU.
  • 72F and confirmed fiber grade/nomenclature.
  • Selected jacket/sheath value.
  • Total cable length, required length per drum or roll, and quantity.
  • Cable marking text and delivery destination.
  • Route/span basis, wind/ice/temperature assumptions and attachment/hardware interface.
  • Required datasheet, drawing, test report or acceptance documents.

Ask BWNFiber to confirm every TBC — source required field before purchase-order release. Price, MOQ, stock, lead time and warranty are not stated in this draft.

Documents and quality-control handoff

Request the approved source revision, construction drawing, optical test matrix and mechanical test conditions for this exact configuration. A real test report, certification or named engineering reviewer may be linked only after BWNFiber supplies and approves it. This draft does not claim a test method, certification or compliance standard that is not visible in the supplied record.

RFQ CTA

Request a 72F ADSS configuration review and quotation. Send the exact fiber/jacket selection, length and drum plan, route/span basis, hardware interface and destination. Ask BWNFiber to return the confirmed source revision and identify any remaining TBC fields before order approval.

FAQ

FAQ

What does 72F mean on this ADSS cable page?
It identifies a 72-fiber configuration in the supplied record. The listed six-tube arrangement implies 12 fibers per tube, but that mapping remains a source-confirmation item before publication.

Is this cable single-mode G.652.D?
The supplied SEO and order rows identify G.652.D2. Confirm the approved nomenclature and exact optical row before treating it as the final ordered fiber grade.

Does 200 m approve every 200 m aerial route?
No. It is the listed product/design designation. Route approval requires the actual spans, wind, ice, temperature, sag-tension, clearances, attachment position and hardware review.

What is the finished cable diameter?
The supplied outer-sheath row lists 12.5 ± 0.5 mm. Confirm that the row is the finished cable diameter in the approved source revision.

What attenuation values are listed?
The supplied optical table lists ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm. Confirm the exact fiber/source row; these values are not a complete link-loss budget.

Which tensile and crush values are listed?
The supplied mechanical table lists 4000 N tensile load and 2200 N/100 mm crush load. Duration and test condition require confirmation.

What temperature conditions apply?
The record lists installation at -30 to +70 °C, operation/transport at -40 to +70 °C and storage/transport at -40 to +75 °C in different rows. Confirm the approved condition labels before publication.

Does this page include connectors or factory termination?
No connector or termination option is listed in the supplied bulk-cable record. Treat splicing, termination and hardware as project-specific and request confirmation.

Can I publish the PMD and bend-radius values now?
No. The supplied review flags missing PMD units and a long-/short-term bend-radius conflict. Engineering/source confirmation is required.

What should I send for a quotation?
Send the exact configuration, fiber grade, jacket, total length, drum plan, quantity, marking, destination, route/load inputs, hardware interface and required documents.

Related Products

Related Products