ADSS 6F / 12F / 24F G.652.D 80m Span 9.2mm Self-Supporting Fiber Optic Cable
ADSS 6F / 12F / 24F G.652.D 80m Span 9.2mm Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 6F / 12F / 24F. Specify span and fiber count against the source drawing.

Product summary
This product record covers an ADSS (all-dielectric self-supporting) aerial fiber optic cable configuration with 6F, 12F or 24F G.652.D fiber options, a PE outer sheath and an 80 m span designation. It is intended for exact-configuration review and quotation, not as a universal approval for every 80 m aerial route.
For a project decision, confirm the route span schedule, sag/tension calculation, wind and ice loading, temperature, clearances, attachment position and compatible ADSS hardware with the route owner or qualified engineer. The selected fiber count, finished-cable diameter and mechanical values must remain together in the approved BOM.
Key configuration facts
| Item | Record value | Release status |
|---|---|---|
| Cable type | ADSS / self-supporting aerial fiber optic cable | Confirm product record |
| Fiber count | 6F / 12F / 24F | Confirm source-row mapping |
| Fiber type | G.652.D single-mode fiber | Confirm datasheet |
| Outer sheath | PE, black listed in the record | Confirm datasheet |
| Span designation | 80 m | Configuration input; not universal route approval |
| Cable size | 9.2 mm nominal in product identifier; 10.6 mm in one construction row | TBC — engineering must reconcile |
| Connectors / fittings | Not identified in the supplied record | TBC — confirm scope |
Fiber-count selection
Choose one row; do not combine construction or mechanical values from different rows.
| Selected count | Fiber grade | Sheath | Span designation | Diameter field | Status |
|---|---|---|---|---|---|
| 6F | G.652.D | PE | 80 m | TBC: 9.2 mm identifier vs 10.6 mm table | Source confirmation required |
| 12F | G.652.D | PE | 80 m | TBC: 9.2 mm identifier vs 10.6 mm table | Source confirmation required |
| 24F | G.652.D | PE | 80 m | TBC: 9.2 mm identifier vs 10.6 mm table | Source confirmation required |
Construction record
The following components are present in the supplied record. The original source file is required to verify which values apply to each count.
| Component / parameter | Supplied record | Status |
|---|---|---|
| Loose tube material | PBT | Confirm source |
| Loose tube diameter | 2.1 mm | Confirm source |
| Central strength member | FRP | Confirm source |
| Dielectric strength member | Kevlar yarn | Confirm source |
| Filling compound | Jelly | Confirm source |
| Water blocking | Water-blocking yarn and tape | Confirm source |
| Outer sheath material | PE | Confirm source |
| Outer sheath color | Black | Confirm source |
| Loose-tube count by fiber count | Ambiguous merged cells in current record | TBC — do not infer |
| Filler count by fiber count | Ambiguous merged cells in current record | TBC — do not infer |
| Finished cable diameter | 9.2 mm identifier / 10.6 mm construction row | TBC — P0 conflict |
| Cable weight | 63 kg/km | Confirm source and tolerance |
Optical characteristics
These values are copied from the supplied V4 record and remain provisional until the approved source is restored.
| Parameter | Record value | Status |
|---|---|---|
| Attenuation @ 1310 nm | ≤0.36 dB/km | Confirm datasheet/test basis |
| Attenuation @ 1550 nm | ≤0.25 dB/km | Confirm datasheet/test basis |
| Maximum α difference @ 1285–1330 nm | ≤0.03 dB/km | Confirm source |
| Maximum α difference @ 1525–1575 nm | ≤0.02 dB/km | Confirm source |
| Zero-dispersion wavelength | 1312 ± 10 nm | Confirm source |
| Zero-dispersion slope | ≤0.090 ps/nm²·km | Confirm source |
| Cable cutoff wavelength | ≤1260 nm | Confirm source |
| MFD @ 1310 nm | 9.2 ± 0.4 μm | Confirm source |
| MFD @ 1550 nm | 10.4 ± 0.5 μm | Confirm source |
| Effective group index @ 1310 nm | 1.466 | Confirm source |
| Effective group index @ 1550 nm | 1.467 | Confirm source |
| Point discontinuity @ 1310 / 1550 nm | ≤0.05 dB | Confirm source |
| PMD: maximum individual fiber | TBC — unit missing in current record | do not use for order release as a final value |
| PMD: link design value (M=20, Q=0.01%) | TBC — unit missing in current record | do not use for order release as a final value |
| PMD: typical value | TBC — unit missing in current record | do not use for order release as a final value |
Mechanical and environmental record
| Parameter | Record value | Use boundary |
|---|---|---|
| Minimum bend radius, static | 10D | Confirm finished-cable diameter and D basis |
| Minimum bend radius, dynamic | 20D | Confirm finished-cable diameter and D basis |
| Tensile strength | 2200 N | Confirm test method and acceptance basis |
| Crush load | 2000 N/100 mm | Confirm test method and acceptance basis |
| Installation temperature | -10 to +60 °C | Confirm source |
| Operation and transport temperature | -20 to +70 °C | Confirm source |
| Span | 80 m | Do not treat as route approval without load/design review |
Application and compatibility boundary
This record is for self-supporting aerial deployment. Confirm the route and installation method before ordering. A G.652.D designation does not by itself prove compatibility with every ADSS fitting, pole line, power-line environment, duct, direct-burial route or connector system.
The supplied record does not identify connectors, termination kits, suspension clamps, dead-end grips, voltage class, wind/ice design case, UV/tracking performance, flame rating or direct-burial approval. Request those items separately when they are required by the project.
For range selection, see BWNFiber’s ADSS outdoor cable range. For broader family selection, review fiber optic cable selection guidance. For a project request, use the project contact page. For general deployment context, see BWNFiber’s fiber optic cable installation guidance.
How to select the correct configuration
- Select 6F, 12F or 24F based on the approved fiber count and reserve plan.
- Specify G.652.D and PE exactly as required by the project record.
- Confirm the finished cable diameter from the approved source; do not choose between 9.2 mm and 10.6 mm by assumption.
- Provide the longest and ruling spans, route angles, attachment position, wind/ice case, temperature and clearance requirements for engineering review.
- Confirm static/dynamic bend limits, tensile/crush values and compatible aerial hardware for the selected count.
- Request the approved datasheet, construction drawing, test basis, packing/reel information and marking requirements before a purchase order.
What differs from related ADSS products
This page owns the 6F/12F/24F, G.652.D, 80 m, small-diameter configuration record. Other BWNFiber ADSS records cover different fiber counts, spans or diameters, such as 24F at 100 m / 12.2 mm and higher-count or longer-span configurations. Compare those pages only after confirming the exact count, finished diameter, sheath/construction and route load case; a similar product name does not make the mechanical values interchangeable.
Testing and quality-control documents
No test report, test method or certification is included in the supplied record. Before release, request the documents applicable to the selected configuration:
- approved product datasheet and construction drawing;
- optical test basis and wavelength-specific attenuation record;
- mechanical test method and acceptance values;
- dimensional/weight tolerance record;
- packing, reel/roll and marking details;
- any project-required standards or certification declaration.
Do not add IEC, ITU-T, TIA, ISO, voltage, UV, tracking, flame, water-penetration or certification claims until BWNFiber provides the applicable evidence.
Packaging and procurement information
The supplied record does not confirm standard reel length, reel dimensions, MOQ, lead time, warranty, price, stock, export packaging or delivery terms. Treat each as TBC — source required. For quotation, state the selected count and approved diameter together with total length, length per drum/roll, quantity, cable marking and delivery destination.
RFQ checklist
Send BWNFiber:
- selected fiber count: 6F, 12F or 24F;
- G.652.D fiber grade;
- PE sheath requirement;
- approved finished-cable diameter;
- route type and span schedule, including ruling/longest span;
- wind, ice, temperature, clearance and attachment inputs where relevant;
- total cable length and length per drum/roll;
- quantity, marking text and delivery destination;
- requested datasheet, drawing, test documents and hardware scope.
CTA: Request an ADSS configuration review and quotation using the checklist above. BWNFiber should confirm the dimensional conflict and return the approved source documents before production or route approval.
Image
Caption: ADSS 6F–24F G.652.D PE cable record. Confirm the finished-cable diameter against the approved source before use in a design or quotation.
Internal review note
This is an offline, evidence-gated draft. It is not a statement that the unresolved values are approved product facts.
FAQ
Which fiber counts are available?
The supplied record lists 6F, 12F and 24F. Select one count and keep its construction and mechanical values together.
Does 80 m mean that every 80 m route is approved?
No. It is a configuration designation. Route approval also depends on span schedule, sag/tension, wind and ice loading, temperature, clearances, attachment position and hardware.
What is the cable diameter?
The current source record is inconsistent: the product identifier says 9.2 mm nominal, while a construction row says 10.6 mm outer sheath diameter. This must be reconciled by engineering before publication or ordering.
Is the fiber single-mode?
The record specifies G.652.D. Do not substitute G.657, G.655 or multimode fiber without written approval.
What jacket is listed?
PE is listed as the outer-sheath material. Other environmental or fire-performance claims require separate evidence.
What strength members are listed?
Kevlar yarn is listed as the strength member and FRP as the central strength member. Confirm the exact count-to-construction mapping from the approved source.
What attenuation is listed?
The V4 record lists ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm. Treat those values as provisional until the approved datasheet or test record is available.
What bend limits are listed?
Static 10D and dynamic 20D are listed. Confirm the finished cable diameter and the D basis before installation planning.
Are connectors or aerial fittings included?
No connector or fitting option is identified in the supplied record. Ask for the exact hardware and termination scope.
Can this cable be used underground?
This page is for self-supporting aerial deployment. Do not infer duct or direct-burial suitability from the ADSS label.
What should be requested before a purchase order?
Request the approved datasheet, construction drawing, dimensional table, optical/mechanical test basis and packing/reel information for the selected count.
What should I include in an RFQ?
Include count, G.652.D, PE, approved diameter, route/span inputs, total length, reel/roll lengths, quantity, marking, destination and required documents.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.