ADSS-600m
ADSS-600m 48F All-Dielectric Self-Supporting Aerial Fiber Optic Cable
ADSS-600m 48F All-Dielectric Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 48F. Specify span and fiber count against the source drawing.

m 48F ADSS Cable at a Glance
BWNFiber’s supplied product record identifies this item as a 600 m, 48F all-dielectric self-supporting aerial fiber optic cable for approved aerial routes. The record lists SM G.652.D, MM 50/125 and MM 62.5/125 as fiber options, PE/HDPE jacket material, an FRP central strength member and a 2 km standard drum length.
These entries are supplied-record values pending engineering and SKU confirmation. The fiber options are alternatives unless the approved configuration sheet states otherwise. A 600 m label does not, by itself, approve a 600 m aerial span: span, sag, wind, ice, temperature, attachment hardware and the selected cable construction must be reviewed together.
For broader product discovery, use the approved ADSS outdoor cable category. For project-specific quotation, submit the configuration and route inputs listed below.
Fiber, Jacket and Construction Options
| Order attribute | Supplied record | Approval status |
|---|---|---|
| Fiber count | 48F | Confirm against the controlled 600 m SKU |
| Single-mode option | G.652.D | Confirm selected configuration |
| Multimode options | 50/125 or 62.5/125 | Confirm whether each is offered for this exact construction |
| Jacket | PE/HDPE | Confirm selected material and any project-specific sheath requirement |
| Central strength member | FRP; 2.1 mm listed | Source and engineering confirmation required |
| Loose-tube material | PBT listed | Source and engineering confirmation required |
| Moisture protection | Water-blocking system listed | Confirm construction and applicable test requirement |
Do not combine the SM and MM alternatives into one product description. The quotation should name one fiber grade, one jacket selection and one controlled construction.
Optical Characteristics
The supplied V4 record lists the following attenuation entries:
| Fiber type | Wavelengths listed | Attenuation listed | Status |
|---|---|---|---|
| SM G.652.D | 1310 / 1550 nm | ≤0.34 / 0.20 dB/km | Confirm test condition and exact configuration |
| MM 50/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Confirm test condition and exact configuration |
| MM 62.5/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Confirm test condition and exact configuration |
The supplied editorial review flags dispersion-slope, PMD and numerical-aperture rows for unit and condition review. Those rows are withheld from this draft until the original source and an engineering reviewer confirm them.
Mechanical and Environmental Data Requiring Confirmation
The supplied V4 file contains repeated columns and values that are not mapped cleanly to one 600 m / 48F configuration. The public page should not treat the following as approved until the source drawing/specification is reconciled:
- outside diameter and tolerance;
- mass per kilometre;
- inner and outer sheath materials and thicknesses;
- tube, filler and water-blocking construction;
- rated tensile strength, maximum allowable tension and EDS;
- installation and operating bend radius;
- installation, transport and operating temperature;
- wind and ice design conditions;
- compatible suspension and dead-end hardware.
Do not transfer a value from another span class, fiber count, sheath construction or adjacent ADSS SKU. The route must be assessed with the exact cable record and the attachment hardware.
How to Prepare an RFQ
Send the following information for a configuration review:
- Product identity:
ADSS-600m 48F All-Dielectric Self-Supporting Aerial Fiber Optic Cable. - Fiber grade: G.652.D, MM 50/125 or MM 62.5/125.
- Jacket selection: PE or HDPE, plus any project-specific sheath requirement.
- Route inputs: span schedule, wind and ice design basis, sag/tension method, attachment arrangement and electrical environment.
- Total cable length, requested length per drum and number of drums.
- Cable marking text and destination.
- Required datasheet, drawing revision and test documentation.
The supplied record lists a 2 km standard drum length. Confirm the actual drum plan for the selected configuration, total length and destination; it is not a universal packing promise.
Route and Installation Checks
Before production or installation approval, confirm that:
- the order identity matches the approved 600 m / 48F source record;
- all mechanical values belong to the same fiber count and sheath construction;
- the route span, sag method and wind/ice design basis have been reviewed;
- suspension and dead-end hardware match the approved cable diameter and load case;
- installation temperature and bend-radius limits are available to the installer;
- optical acceptance requirements and document deliverables are defined;
- the image and diagram used on the page match the exact controlled SKU.
All-dielectric construction does not by itself prove suitability for every power-line or aerial environment. Project-specific electrical, mechanical and safety requirements remain applicable. If the route requires dedicated attachment hardware, review the approved ADSS suspension hardware range separately; the hardware page owns clamp selection.
Comparison questions should remain on the approved ADSS versus drop-cable guide, rather than turning this exact-SKU page into a general comparison article.
Request a Configuration Review
Send the fiber grade, jacket, route span/load information, total length, drum plan, marking and destination for a configuration-complete quotation. BWNFiber can then confirm which source revision, mechanical values and test documents apply to the selected 600 m / 48F cable. Use the approved BWNFiber contact page only after the route inputs are assembled.
Evidence note: Product-specific values in this offline draft come from the supplied BWNFiber V4 record and remain subject to SKU and engineering confirmation. No CMS changes or publication are included.
Disclaimer: This offline draft is not an engineering approval, certification, performance guarantee or promise of delivery. Confirm the controlled source revision, test conditions and ordered configuration before quotation, production or installation.
Frequently Asked Questions
What fiber count does this page cover?
The supplied record identifies a 48F configuration. Confirm the controlled SKU and approved source revision before quotation because an adjacent local record has a conflicting span identity.
Is 600 m the permitted aerial span?
Not automatically. The product label and a route span are different decisions. Span approval requires the exact cable construction, route geometry, sag/tension method, wind and ice design basis, temperature and attachment hardware.
Which fiber grades are listed?
The supplied record lists SM G.652.D, MM 50/125 and MM 62.5/125. Treat them as alternative order configurations unless an approved configuration sheet permits a mixed-fiber design.
Is PE/HDPE a fire-test classification?
No. A jacket material name does not establish a fire-test classification. Specify any required classification separately and request the supporting evidence.
What should I send for an accurate quotation?
Send the exact product identity, fiber grade, jacket, route inputs, total length, drum plan, marking text, destination and required documents. Ask for one configuration-specific specification sheet.
Is the 2 km drum length available for every order?
The supplied record lists 2 km as a standard drum length. Confirm the actual drum plan for the selected configuration, total length and destination.
Which mechanical values still require confirmation?
The V4 file requires review of the multi-column tables for diameter, weight, temperatures, bend radius, tension, wind/ice conditions and sheath details. Do not approve these values from the draft alone.
Can the listed optical alternatives be combined in one cable?
Not by default. Select one approved fiber configuration unless the engineering source explicitly permits a mixed-fiber design.
Does an ADSS cable replace route engineering?
No. ADSS describes a self-supporting cable construction. It does not replace review of span, sag, attachment, environmental and electrical conditions.
Related Products