ADSS Cable

ADSS 48F / 96F G.652.D 80m Span Self-Supporting Aerial Fiber Optic Cable

ADSS 48F / 96F G.652.D 80m Span Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 48F / 96F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS

Product summary

The BWNFiber ADSS 48F / 96F G.652.D 80 m record is for an all-dielectric, self-supporting aerial fiber optic cable configuration. The supplied record covers two fiber-count options, G.652.D fiber, a nominal 80 m span designation, loose-tube construction, water-blocking yarns, an FRP central strength member and a black PE/HDPE sheath listing. The final ordered row must be confirmed against the approved source revision before release.

Configuration selector

Field48F96FRelease status
Fiber count4896Supplied V4
Fiber gradeG.652.DG.652.DConfirm optical/order-row alignment
Loose tubes48Confirm source-row mapping
Maximum fibers per tube1212Confirm source-row mapping
Central strength memberFRPFRPConfirm diameter row
SheathPE/HDPE listed in sourcePE/HDPE listed in sourceSelect one approved ordered value
Nominal span designation80 m80 mRoute-specific approval required

Do not combine a 48F diameter, 96F weight, alternate jacket or different optical row in one quotation. Ask BWNFiber to return one complete configuration row.

Technical data requiring source confirmation

The supplied V4 tables contain multi-column values that require engineering review. Keep the CMS table in the following normalized format only after each value is confirmed:

ParameterCondition48F96FEvidence status
Loose-tube outer diameterFinished tube2 mm listed2 mm listedConfirm row alignment
Loose-tube thicknessFinished tube0.3 mm listedTBCSource required
Central member diameterFRP2.1 mm listed2.1 mm listedConfirm row alignment
PE layer diameterCentral member layerTBC3.4 mm listedSource required
Finished cable diameterApproximate9.6 mm listed10.9 mm listedConfirm count mapping
Finished cable weightApproximate80 kg/km listed100 kg/km listedConfirm count mapping
MATUnit shown as kN1.3 listed1.3 listedDefine term and basis
Attenuation1310 nm≤0.36 dB/km listed≤0.36 dB/km listedNormalize approved optical matrix
Attenuation1550 nm≤0.22 dB/km listed≤0.22 dB/km listedNormalize approved optical matrix

MAT, mechanical limits, temperature conditions, wind/ice design cases and test methods must not be expanded beyond the approved source. If the source does not define them, show TBC — source required.

Application and route boundary

This cable record is intended for review in self-supporting aerial routes. Route approval requires the actual span schedule, wind and ice assumptions, installation temperature, sag-tension calculation, clearances, attachment position, hardware interface and the exact cable revision. The 80 m designation should be treated as a product-design input, not a universal installation permission.

For broader model discovery, link to BWNFiber’s ADSS cable selection page. For the route-level product-family boundary, link to the fiber optic cable selection page. Hardware matching can be supported by the FTTx installation hardware guide. These links serve different tasks from this exact-configuration page and should not use this page’s exact product keyword as their anchor.

How to choose the configuration

  1. Select 48F or 96F based on the required active fibers, spare capacity and approved project design.
  2. Confirm G.652.D as the ordered fiber grade; do not mix it with alternate fiber rows.
  3. Match the confirmed finished diameter and weight to the selected suspension/dead-end hardware and drum plan.
  4. Confirm the jacket, mechanical basis and optical matrix against one approved source revision.
  5. Send the complete configuration and route inputs to BWNFiber for quotation review.

RFQ checklist

Include:

  • 48F or 96F;
  • G.652.D;
  • 80 m designation and the project span/load basis;
  • exact approved jacket value;
  • total cable length and requested length per drum;
  • quantity, marking text and delivery destination;
  • attachment/hardware interface and required cable diameter;
  • requested datasheet, drawing and test-document revision.

Ask BWNFiber to flag any field that remains TBC — source required before purchase-order release.

Packing

The supplied V4 contains count-specific drum rows, but the row labels use ADSS 48C and ADSS 96C while the product identity uses 48F and 96F. Keep the packing table out of publishable copy until the source owner confirms the labels, drum length and dimensions. Do not assert a universal 4,000 m drum length until that reconciliation is complete.

CTA

Request a configuration review and quotation. Send the RFQ fields above and ask BWNFiber to confirm the complete 48F or 96F row, source revision and any project-specific design inputs before order approval.

Use the site’s confirmed contact/inquiry path only after the production owner verifies the final destination URL and form tracking.

Image and schema handoff

  • Existing image: preserve the supplied WebP only after visual identity/source QA.
  • Recommended alt: BWNFiber ADSS 48F and 96F G.652.D 80 m self-supporting aerial fiber optic cable
  • Product schema: recommend only after CMS schema audit; no price, offer, stock, rating, review, certification or unsupported image claims.
  • FAQPage/BreadcrumbList: recommend only if visible FAQ/breadcrumb content exists and existing Yoast output is checked for duplication.
FAQ

FAQ

Does 80 m mean that every route may use an 80 m span?
No. It is the designation in the supplied product record. The permitted route depends on span geometry, wind, ice, temperature, sag-tension, clearances, attachment hardware and the approved cable revision.

What is the difference between the 48F and 96F options?
The supplied record lists 48 and 96 fibers, with four and eight loose tubes respectively. Confirm the complete count-specific mechanical row before selecting hardware or packing.

Is the ordered fiber G.652.D?
G.652.D is listed in the order guide. Confirm that the optical table uses the same approved fiber row before quotation; do not combine alternate optical values.

Which jacket should be quoted?
The source lists PE/HDPE-related sheath fields. Select one exact approved jacket value and thickness in the RFQ. Do not infer fire, electrical or certification properties from the material name alone.

Can the MAT value approve an installation?
No. The supplied table lists 1.3 kN, but the term and design/test basis must be confirmed. It is not a substitute for project-specific sag-tension review.

What should I send for a comparable quotation?
Send the count, G.652.D grade, exact jacket, total length, drum plan, route/span basis, hardware interface, marking, destination and required document revision.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.