ADSS-300m 48F All-Dielectric Self-Supporting Aerial Fiber Optic Cable

ADSS-300m 48F All-Dielectric Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 48F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS-300m

What this product page covers

This page covers the BWNFiber ADSS-300m 48F all-dielectric, self-supporting aerial fiber optic cable configuration. The supplied record identifies 48 fibers, a loose-tube construction, FRP central strength member, water-blocking materials, Kevlar yarn reinforcement and a PE/HDPE sheath option.

Important configuration boundary: “ADSS-300m” is the supplied product model name. It is not, by itself, approval to install the cable over a 300 m span. Span, sag, tension, wind, ice, clearances, attachment hardware and the selected cable’s approved load data must be reviewed for the actual route.

Key configuration facts

  • Fiber count: 48F / 48 cores
  • Tube arrangement in the supplied order row: 4 tubes, 12 fibers per tube
  • Fiber options listed in the supplied record: SM G.652.D, MM 50/125, and MM 62.5/125
  • Jacket entries in the supplied record: PE/HDPE
  • Central strength member: FRP; 2.1 mm stated in the source record
  • Loose tube: PBT; 2.0 mm outer/inner field stated in the source record
  • Overall diameter: 12.50 mm stated in the source record
  • Standard drum length: 2 km stated in the source record

The fiber and jacket entries are alternatives, not values to combine. Ask BWNFiber to confirm the single approved configuration before quotation or production release.

Construction and technical specifications

ParameterSupplied valueStatus
Fiber count48F / 48 coresSupplied product record
Tube count4Supplied order row
Fibers per tube12Supplied order row
Fiber typeG.652.D in the order row; SM G.652.D / MM 50/125 / MM 62.5/125 listed as optionsConfirm one approved option
Central strength memberFRPSupplied product record
Central strength member diameter2.1 mmSupplied product record; confirm drawing
Loose-tube materialPBTSupplied product record
Loose-tube diameter2.0 mm outer/inner fieldEngineering review required
Filling / water blockingTube-filling compound, cable-filling compound, water-blocking systemSupplied product record
Inner sheathPESupplied product record
Outer sheathPE/HDPEConfirm selected jacket
Overall cable diameter12.50 mmSupplied product record; reconcile with drawing
Cable weight125.0 kg/kmSupplied product record; reconcile with table
Operation bend radius240 mmSupplied product record; confirm basis
Installation bend radius390 mmSupplied product record; confirm basis
Rated tensile strength (RTS)17.5 kNSupplied product record; confirm units/test basis
Maximum allowed tension (MAT)7.5 kNSupplied product record; confirm units/test basis
Annual average running tension (EDS)3.7 kNSupplied product record; confirm units/test basis
Wind / ice entries35 m/s wind; 5 mm iceSupplied product record; route/load review required
Temperature entriesInstallation -15 to +60; operation/transport -40 to +70Confirm labels and units
Optical attenuationSM G.652D: ≤0.34/0.20 dB/km at 1310/1550 nm; MM rows also listedConfirm approved optical matrix and conditions

Source discrepancies that must be resolved before publication

The supplied record contains a 1.7 ± 0.2 mm outer-sheath diameter field that does not clearly reconcile with the stated 12.50 mm overall diameter. It also contains repeated/corrupted multi-column rows and unresolved optical rows for dispersion, PMD and numerical aperture. These values are intentionally not normalized or substituted here. Request the current engineering-approved datasheet and construction drawing.

Fiber and order selection

Use one complete configuration in the quotation:

Fiber countTube arrangementFiber optionJacket
48F4 × 12FSelect one approved SM or MM optionSelect PE or HDPE as approved

Do not combine the attenuation row for one fiber grade with the mechanical or jacket row of another option. If the project requires G.652.D, state that explicitly. If a multimode option is required, request its approved construction, optical limits and application evidence separately.

Application and compatibility conditions

ADSS is intended for an engineered aerial route where the cable is self-supporting between approved attachment points. Confirm the route’s maximum and ruling spans, sag-tension case, wind and ice loading, temperature, clearances, attachment hardware, pole or tower interface and maintenance conditions.

This page does not establish suitability for direct burial, duct installation, indoor pathways, a particular utility voltage, or a particular connector/termination system. Those uses require a model-specific and project-specific review.

What to include in an RFQ

Please send:

  1. Required fiber grade and whether the project is single-mode or multimode.
  2. Fiber count confirmation: 48F.
  3. Route type, longest/ruling span, wind and ice design inputs, temperature and attachment conditions.
  4. Jacket choice: PE or HDPE, plus any separately required project classification.
  5. Total cable length, required length per drum/roll, quantity and delivery destination.
  6. Cable marking text, packing/traceability requirements and required approval documents.
  7. Any drawing, datasheet revision, test method or acceptance record required by the project.

Testing and documents

The supplied file does not provide a complete approved test method, test equipment, report number, construction drawing or inspection-and-test plan for this configuration. These are TBC — source required. Request them before technical approval; do not infer compliance from the ADSS name, jacket material or a competitor datasheet.

Request a configuration-specific review

Send the route information, selected fiber option, jacket, total length and required documents for a configuration review and quotation. Final values remain subject to BWNFiber engineering confirmation and the approved project specification.

FAQ

FAQ

Is this a 300 m aerial-span cable?

The supplied product name is ADSS-300m. That model name does not by itself authorize a 300 m span. The permitted span must be calculated and approved from the exact cable data and route loading conditions.

Which fiber count does this page cover?

It covers 48F / 48 cores. Other fiber counts are separate configurations and should not inherit this page’s dimensions or mechanical values.

Can I combine the SM and MM optical values?

No. SM G.652.D, MM 50/125 and MM 62.5/125 are listed as alternatives in the supplied record. Select one approved fiber option and request its matching construction and optical data.

What jacket is available?

The supplied record lists PE/HDPE. State the selected jacket in the RFQ and ask BWNFiber to confirm the exact material, thickness and project requirements.

What documents should be reviewed before release?

At minimum, request the configuration-specific datasheet, construction drawing, optical/mechanical limits, installation guidance, marking/packing details and any required test or compliance evidence. The supplied record does not include a complete approved document set.

What information is needed for a quotation?

Send the 48F fiber choice, route and loading inputs, jacket, total length, drum plan, quantity, marking and destination. Include the project’s required drawings, test records and approval format.