What this product page covers
This page covers the BWNFiber ADSS-300m 48F all-dielectric, self-supporting aerial fiber optic cable configuration. The supplied record identifies 48 fibers, a loose-tube construction, FRP central strength member, water-blocking materials, Kevlar yarn reinforcement and a PE/HDPE sheath option.
Important configuration boundary: “ADSS-300m” is the supplied product model name. It is not, by itself, approval to install the cable over a 300 m span. Span, sag, tension, wind, ice, clearances, attachment hardware and the selected cable’s approved load data must be reviewed for the actual route.
Key configuration facts
- Fiber count: 48F / 48 cores
- Tube arrangement in the supplied order row: 4 tubes, 12 fibers per tube
- Fiber options listed in the supplied record: SM G.652.D, MM 50/125, and MM 62.5/125
- Jacket entries in the supplied record: PE/HDPE
- Central strength member: FRP; 2.1 mm stated in the source record
- Loose tube: PBT; 2.0 mm outer/inner field stated in the source record
- Overall diameter: 12.50 mm stated in the source record
- Standard drum length: 2 km stated in the source record
The fiber and jacket entries are alternatives, not values to combine. Ask BWNFiber to confirm the single approved configuration before quotation or production release.
Construction and technical specifications
| Parameter | Supplied value | Status |
|---|---|---|
| Fiber count | 48F / 48 cores | Supplied product record |
| Tube count | 4 | Supplied order row |
| Fibers per tube | 12 | Supplied order row |
| Fiber type | G.652.D in the order row; SM G.652.D / MM 50/125 / MM 62.5/125 listed as options | Confirm one approved option |
| Central strength member | FRP | Supplied product record |
| Central strength member diameter | 2.1 mm | Supplied product record; confirm drawing |
| Loose-tube material | PBT | Supplied product record |
| Loose-tube diameter | 2.0 mm outer/inner field | Engineering review required |
| Filling / water blocking | Tube-filling compound, cable-filling compound, water-blocking system | Supplied product record |
| Inner sheath | PE | Supplied product record |
| Outer sheath | PE/HDPE | Confirm selected jacket |
| Overall cable diameter | 12.50 mm | Supplied product record; reconcile with drawing |
| Cable weight | 125.0 kg/km | Supplied product record; reconcile with table |
| Operation bend radius | 240 mm | Supplied product record; confirm basis |
| Installation bend radius | 390 mm | Supplied product record; confirm basis |
| Rated tensile strength (RTS) | 17.5 kN | Supplied product record; confirm units/test basis |
| Maximum allowed tension (MAT) | 7.5 kN | Supplied product record; confirm units/test basis |
| Annual average running tension (EDS) | 3.7 kN | Supplied product record; confirm units/test basis |
| Wind / ice entries | 35 m/s wind; 5 mm ice | Supplied product record; route/load review required |
| Temperature entries | Installation -15 to +60; operation/transport -40 to +70 | Confirm labels and units |
| Optical attenuation | SM G.652D: ≤0.34/0.20 dB/km at 1310/1550 nm; MM rows also listed | Confirm approved optical matrix and conditions |
Source discrepancies that must be resolved before publication
The supplied record contains a 1.7 ± 0.2 mm outer-sheath diameter field that does not clearly reconcile with the stated 12.50 mm overall diameter. It also contains repeated/corrupted multi-column rows and unresolved optical rows for dispersion, PMD and numerical aperture. These values are intentionally not normalized or substituted here. Request the current engineering-approved datasheet and construction drawing.
Fiber and order selection
Use one complete configuration in the quotation:
| Fiber count | Tube arrangement | Fiber option | Jacket |
|---|---|---|---|
| 48F | 4 × 12F | Select one approved SM or MM option | Select PE or HDPE as approved |
Do not combine the attenuation row for one fiber grade with the mechanical or jacket row of another option. If the project requires G.652.D, state that explicitly. If a multimode option is required, request its approved construction, optical limits and application evidence separately.
Application and compatibility conditions
ADSS is intended for an engineered aerial route where the cable is self-supporting between approved attachment points. Confirm the route’s maximum and ruling spans, sag-tension case, wind and ice loading, temperature, clearances, attachment hardware, pole or tower interface and maintenance conditions.
This page does not establish suitability for direct burial, duct installation, indoor pathways, a particular utility voltage, or a particular connector/termination system. Those uses require a model-specific and project-specific review.
What to include in an RFQ
Please send:
- Required fiber grade and whether the project is single-mode or multimode.
- Fiber count confirmation: 48F.
- Route type, longest/ruling span, wind and ice design inputs, temperature and attachment conditions.
- Jacket choice: PE or HDPE, plus any separately required project classification.
- Total cable length, required length per drum/roll, quantity and delivery destination.
- Cable marking text, packing/traceability requirements and required approval documents.
- Any drawing, datasheet revision, test method or acceptance record required by the project.
Testing and documents
The supplied file does not provide a complete approved test method, test equipment, report number, construction drawing or inspection-and-test plan for this configuration. These are TBC — source required. Request them before technical approval; do not infer compliance from the ADSS name, jacket material or a competitor datasheet.
Request a configuration-specific review
Send the route information, selected fiber option, jacket, total length and required documents for a configuration review and quotation. Final values remain subject to BWNFiber engineering confirmation and the approved project specification.
FAQ
Is this a 300 m aerial-span cable?
The supplied product name is ADSS-300m. That model name does not by itself authorize a 300 m span. The permitted span must be calculated and approved from the exact cable data and route loading conditions.
Which fiber count does this page cover?
It covers 48F / 48 cores. Other fiber counts are separate configurations and should not inherit this page’s dimensions or mechanical values.
Can I combine the SM and MM optical values?
No. SM G.652.D, MM 50/125 and MM 62.5/125 are listed as alternatives in the supplied record. Select one approved fiber option and request its matching construction and optical data.
What jacket is available?
The supplied record lists PE/HDPE. State the selected jacket in the RFQ and ask BWNFiber to confirm the exact material, thickness and project requirements.
What documents should be reviewed before release?
At minimum, request the configuration-specific datasheet, construction drawing, optical/mechanical limits, installation guidance, marking/packing details and any required test or compliance evidence. The supplied record does not include a complete approved document set.
What information is needed for a quotation?
Send the 48F fiber choice, route and loading inputs, jacket, total length, drum plan, quantity, marking and destination. Include the project’s required drawings, test records and approval format.