ADSS Cable

ADSS 24F G.652.D 300m Span 12.5mm Self-Supporting Fiber Optic Cable

ADSS 24F G.652.D 300m Span 12.5mm Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 24F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS

Product value summary

This page covers one proposed BWNFiber ADSS configuration: 24 fibers, G.652.D3, HDPE, 12.5±0.5 mm outer diameter and a 300 m span designation. The cable is described as an all-dielectric, self-supporting aerial cable with an FRP central strength member, aramid yarn reinforcement, four loose tubes and water-blocking materials. Confirm the controlled datasheet and route calculation before treating any span or mechanical value as an installation approval.

Short answer for buyers

Choose this page when your requirement is specifically a 24F G.652.D ADSS cable in the listed 12.5 mm / 300 m configuration. A route engineer or line owner must still review the governing spans, sag, wind, ice, temperature, clearances, attachment position and compatible hardware. If the source record, image or fiber nomenclature does not match your project requirement, stop the RFQ and request the corrected model record.

Key features

  • Fiber count: 24F.
  • Fiber type: G.652.D3 — confirm whether the public designation should be G.652.D or G.652.D3.
  • Outer sheath: HDPE, black in the supplied table.
  • Outer diameter: 12.5±0.5 mm in the supplied table.
  • Central strength member: FRP.
  • Reinforcement: Kevlar/aramid yarn.
  • Construction: four PBT loose tubes, two fillers, jelly filling and water-blocking yarn/gel in the supplied record.
  • No factory connector or hardware interface is listed. TBC — source required.

Configuration lock

FieldThis page coversPublication condition
Fiber count24FConfirm against approved source
Fiber designationG.652.D3Confirm public nomenclature
Cable familyADSS outdoor cableConfirm exact product record
Model/span designation300 mDo not treat as universal route approval
Outer sheathHDPE, blackConfirm source row and electrical environment
Outer diameter12.5±0.5 mmConfirm measurement basis
Public part numberTBC — source requiredEngineering/product owner

Technical specifications

Cable construction

ParameterSupplied valueEvidence status
Fiber count24FSupplied V4 / F0200; verify source sheet
Loose tubes4Supplied V4 / F0200; verify source sheet
Fillers2Supplied V4 / F0200; verify source sheet
Loose tube materialPBTSupplied V4 / F0200; verify source sheet
Loose tube diameter2 mmSupplied V4; unit/row mapping requires source check
Central strength memberFRPSupplied V4 / F0200
Strength memberKevlar yarnSupplied V4 / F0200
Loose-tube fillingJellySupplied V4 / F0200
Moisture barrierWater-blocking yarn and gelSupplied V4 / F0200
Inner sheathPE, black, 8.0±0.2 mmSupplied V4; verify source row
Outer sheathHDPE, black, 12.5±0.5 mmSupplied V4; verify source row

Optical characteristics

ParameterSupplied valueEvidence status
Attenuation @ 1310 nm≤0.36 dB/kmSupplied V4; verify approved datasheet
Attenuation @ 1550 nm≤0.25 dB/kmSupplied V4; verify approved datasheet
Maximum α difference, 1285–1330 nm≤0.03 dB/kmSupplied V4; verify approved datasheet
Maximum α difference, 1525–1575 nm≤0.02 dB/kmSupplied V4; verify approved datasheet
Zero-dispersion wavelength1312±10 nmSupplied V4; verify approved datasheet
Zero-dispersion slope≤0.090 ps/nm²·kmSupplied V4; verify approved datasheet
Cable cutoff wavelength≤1260 nmSupplied V4; verify symbol/unit
MFD @ 1310 nm9.2±0.4 μmSupplied V4; verify approved datasheet
MFD @ 1550 nm10.4±0.5 μmSupplied V4; verify approved datasheet
Effective group index @ 1310 nm1.466Supplied V4; verify approved datasheet
Effective group index @ 1550 nm1.467Supplied V4; verify approved datasheet
Point discontinuities @ 1310/1550 nm≤0.05 dBSupplied V4; verify approved datasheet
PMD maximum individual fiberTBC — unit/source requiredF0200 editorial review identifies missing unit
PMD link design valueTBC — unit/source requiredF0200 editorial review identifies missing unit
PMD typical valueTBC — unit/source requiredF0200 editorial review identifies missing unit

Mechanical and environmental inputs

ParameterSupplied valueEvidence status
Model/span designation300 mSupplied V4; route approval is project-specific
Maximum tensile load4500 NSupplied V4; test duration/basis TBC
Crush load2200 N/100 mmSupplied V4; test duration/basis TBC
Installation temperature-30 to +70 °CSupplied V4; verify source
Operation and transport temperature-40 to +70 °CSupplied V4; verify source
Storage/transport field in construction table-40 to +75 °CSupplied V4; reconcile with mechanical table
Minimum bend radiusTBC — engineering review requiredF0200 says 15D/10D rows are internally inconsistent

Interfaces and connector options

This is a bare outdoor cable record. No factory connector, termination, polarity, gender, end face or hardware interface is specified in the supplied V4. Do not add connector or clamp compatibility claims. Request the approved construction drawing and hardware schedule when the route requires suspension, dead-end, vibration-control or downlead components.

Fiber type and configuration options

The supplied order row is 24F / G.652.D3 / HDPE / 12.5±0.5 / Kevlar yarn. Do not combine this row with values from another fiber count, span, sheath or multimode alternative. If the project requires another fiber grade or count, quote it as a separate approved configuration rather than changing this page’s facts.

Compatibility and application conditions

The listed use is a self-supporting aerial route. Suitability depends on route geometry and environmental loading, not on the phrase “300 m” alone. Confirm maximum and ruling spans, sag, wind, ice, temperature, clearances, attachment position, route angle, cable weight/diameter and hardware before installation. Underground, duct, direct-buried, figure-8 and FTTH-drop applications belong to other product roles unless a project-specific engineering review says otherwise.

How to select the correct configuration

  1. Confirm the route is an ADSS self-supporting aerial application.
  2. Provide every span, including the maximum and ruling span, plus route angles and attachment positions.
  3. State wind, ice, temperature, altitude, pollution and electrical-environment inputs required by the project.
  4. Confirm 24F capacity, G.652.D requirement, sheath preference and reserve/splice plan.
  5. Match one exact cable record to the approved diameter, weight, MAT/RTS basis, sag calculation and fittings.
  6. Request the controlled datasheet, drawing, calculation basis and inspection/test documents before commercial release.

Differences from related products

Related page typeHow it differs from this page
BWNFiber ADSS categorySelects among ADSS families by span, load, environment and hardware; it is not this exact 24F record.
24F / 100 m / 12.2 mm ADSS pageDifferent span and diameter designation; do not merge specifications.
48F / 120 m / 12.5 mm ADSS pageSame nominal diameter but different fiber count and span; mechanical values are not interchangeable.
ADSS installation/selection guideExplains route engineering and comparisons; this page should not duplicate its broad content.
Figure-8, duct, direct-buried or FTTH-drop cableDifferent support/installation roles; compare only through the approved application guide.

Use cases

  • A procurement request for the specific 24F G.652.D ADSS configuration.
  • A preliminary shortlist for a self-supporting aerial telecom or utility route, pending route and load approval.
  • A supplier comparison where all bidders are required to quote the same fiber count, sheath, diameter, span basis, drum plan and evidence package.

These are application categories, not BWNFiber project case studies or a guarantee of suitability.

Testing and quality-control process

The supplied page does not include an approved test method, test report, inspection plan or acceptance criterion for this exact configuration. Do not claim tests passed. Request, as applicable to the project:

  • controlled product datasheet and construction drawing;
  • optical acceptance table with wavelengths and units;
  • mechanical/environmental test methods, duration and limits;
  • route/sag-tension calculation basis;
  • drum-length and marking record;
  • final inspection or routine-test report for the ordered configuration.

TBC — source required: applicable standard, test method, report revision and acceptance owner.

Packaging and procurement information

The supplied V4 requests total cable length, length per drum or roll, quantity, cable marking text and destination. It does not provide an approved standard drum length, reel type, tolerance, shipping protection or end-cap specification. Confirm those fields in the quotation and controlled packing instructions.

Required information for an RFQ

Send:

  • product reference: ADSS 24F G.652.D 300m Span 12.5mm Self-Supporting Fiber Optic Cable;
  • approved fiber designation and fiber count;
  • total length, requested length per drum/roll and quantity;
  • route span schedule, wind/ice/temperature basis, clearances and attachment position where relevant;
  • sheath/environment requirement and required hardware scope;
  • cable marking text, destination and requested delivery documents;
  • required datasheet, drawing, calculation, test and inspection records.

Datasheet / drawing / test-report area

DocumentStatus
Approved P061 datasheetTBC — source required
Construction/cross-section drawingTBC — source required
Route/sag-tension calculationProject-specific; not supplied
Optical test reportTBC — source required
Mechanical/environmental test reportTBC — source required
Packing/drum and marking instructionTBC — source required

RFQ / CTA

Request the approved datasheet, drawing and configuration-specific quotation. Include the route span schedule, load/environment basis, fiber requirement, total length, drum plan, marking text, destination and required inspection documents. BWNFiber should confirm the exact model record before commercial release.

FAQ

FAQ

Which configuration does this page cover?
The proposed record covers 24F, G.652.D3, HDPE, 12.5±0.5 mm and a 300 m span designation. Confirm the approved public part number and source revision before ordering.

Does “300 m span” approve every 300 m aerial route?
No. Treat it as the named configuration/span input. Route approval also requires the span schedule, sag, wind, ice, temperature, clearances, attachment position, hardware and calculation basis.

What fiber count is specified?
24F. A different count is a different configuration and should not inherit this page’s diameter or mechanical values.

What outer diameter is listed?
The supplied record lists 12.5±0.5 mm. Confirm the measurement basis against the approved drawing before selecting clamps or planning entry hardware.

What are the listed attenuation values?
The supplied table lists ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm. These are not a complete link-loss budget including connectors, splices and other passive elements.

Which mechanical values are listed?
The supplied record lists 4500 N maximum tensile load and 2200 N/100 mm crush load. The test condition, duration and design basis must be confirmed before engineering use.

What bend radius should be used?
The current editorial review identifies an internal 15D/10D inconsistency. do not use for order release or use a bend-radius value until engineering confirms which value applies to installation and operation.

Does the page include connectors or suspension hardware?
No connector or hardware interface is specified in the supplied record. Request a compatible hardware schedule and drawing for the route.

What documents should be requested?
Request the approved datasheet, construction drawing, optical/mechanical test basis, route calculation inputs, packing/marking instruction and any project acceptance records.

What should be included in the RFQ?
State the exact configuration, total length, drum/roll length, quantity, route/load inputs, cable marking, delivery destination and required approval documents.