ADSS Cable

ADSS 24F G.652.D 100m Span 12.2mm Self-Supporting Fiber Optic Cable

ADSS 24F G.652.D 100m Span 12.2mm Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 24F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS

Product summary

The BWNFiber ADSS 24F G.652.D1 100 m span cable record identifies a 24-fiber, all-dielectric self-supporting aerial configuration with a listed outer diameter of 12.2 ± 0.5 mm. The supplied construction table lists four loose tubes, two fillers, PBT loose-tube material, an FRP central strength member, Kevlar yarn, water-blocking materials, PE inner sheath and HDPE outer sheath.

The 100 m span is a product-record designation, not approval for every 100 m aerial route. Final suitability requires the route span schedule, ruling span, wind and ice loading, temperature, sag/clearance assumptions, attachment position and compatible hardware. TBC — BWNFiber engineering must confirm the controlling load case and installation hardware.

Quick buyer answer

For a 24F ADSS cable request, keep one complete configuration together: G.652.D1 label, 12.2 ± 0.5 mm diameter, 100 m designation, sheath/construction rows, total length, drum or roll length, quantity, marking and destination. Do not combine optical or mechanical values from another fiber count, span or source revision. Ask for the controlled drawing, test schedule and current specification before purchase-order release.

Key features from the supplied record

  • Fiber count: 24F
  • Fiber label: G.652.D1 — confirm grade notation before publication
  • Application stated: self-supporting aerial fiber route
  • Outer sheath: HDPE, black
  • Cable diameter: 12.2 ± 0.5 mm
  • Loose tubes: 4; PBT; listed diameter 2 mm
  • Fillers: 2
  • Central strength member: FRP
  • Strength member: Kevlar yarn
  • Moisture-related rows: water-blocking yarn and gel; filling compound listed as jelly
  • Storage/transport and operating limits: source rows conflict; see environmental section

Configuration and construction

Component or parameterSupplied valuePublication status
Fiber count24F / 24Publish after source-row check
Fiber typeG.652.D1Confirm grade/notation
Loose-tube count4Publish after source-row check
Filler count2Publish after source-row check
Loose tubePBT; listed diameter 2 mmConfirm whether diameter is OD and add unit
Central strength memberFRPConfirm exact material designation
Strength memberKevlar yarnConfirm placement/role
Filling compoundJellyConfirm controlled material term
Moisture barrierWater-blocking yarn and gelConfirm construction wording
Inner sheathPE; black; 8.0 ± 0.2 mmConfirm whether this is sheath OD
Outer sheathHDPE; black; 12.2 ± 0.5 mmConfirm OD definition and tolerance

Optical characteristics

The following values are reproduced from the supplied record and must remain paired with their stated wavelength/condition. They are not a complete link-loss budget and must not be described as a finished-cable acceptance report until BWNFiber confirms the test basis.

Parameter / conditionSupplied valueStatus
Attenuation @ 1310 nm≤0.36 dB/kmConfirm fiber vs cable basis
Attenuation @ 1550 nm≤0.25 dB/kmConfirm fiber vs cable basis
Maximum α difference @ 1285–1330 nm≤0.03 dB/kmConfirm source label/method
Maximum α difference @ 1525–1575 nm≤0.02 dB/kmConfirm source label/method
Zero-dispersion wavelength1312 ± 10 nmConfirm test basis
Zero-dispersion slope≤0.090 ps/nm²·kmConfirm notation
Cable cutoff wavelength≤1260 nmConfirm source notation (λcc)
MFD @ 1310 nm9.2 ± 0.4 μmConfirm grade
MFD @ 1550 nm10.4 ± 0.5 μmConfirm grade
Effective group index @ 1310 nm1.466Confirm source basis
Effective group index @ 1550 nm1.467Confirm source basis
Point discontinuities @ 1310/1550 nm≤0.05 dBConfirm test method
Cladding diameter124.8 ± 0.7 μmConfirm grade
Cladding non-circularity≤0.7%Confirm grade
Coating diameter254 ± 5 μmConfirm grade
Coating–cladding concentricity error≤12.0 μmConfirm grade
Coating non-circularity≤6.0%Confirm grade
Core–cladding concentricity error≤0.5 μmConfirm grade
Curl radius≥4 mConfirm source term
PMD maximum individual fiber≤0.2 [unit TBC]do not use for order release as final
PMD link design value (M=20, Q=0.01%)≤0.1 [unit TBC]do not use for order release as final
PMD typical value0.04 [unit TBC]do not use for order release as final

Mechanical and environmental limits

ParameterSupplied valuePublication status
Span designation100 mPublish only with route-approval limitation
Maximum tensile load2,400 NKeep label; request duration/test method
Crush load2,200 N/100 mmKeep label; request duration/test method
Installation temperature−30 to +70 °CConfirm source revision
Operation and transport temperature−40 to +70 °CConfirm source revision
Storage/transport temperature in construction table−40 to +75 °CTBC — conflicts with +70 °C row
Minimum bend radius, long term15DWithhold — editorial review flags ordering conflict
Minimum bend radius, short term10DWithhold — editorial review flags ordering conflict

Use the controlling datasheet and approved installation method for field handling. Do not relabel the 2,400 N value as RTS, MAT, EDS or continuous service tension without an engineering definition.

Application and compatibility boundary

This configuration is described for self-supporting aerial fiber routes. The supplied record does not approve a utility voltage, wind/ice class, attachment position, sag calculation, suspension clamp, dead-end grip or route clearance. It also does not establish suitability for duct, direct burial, FTTH drop, armored, indoor or data-center use. A route owner or qualified engineer must approve the installed system.

How to select and quote this configuration

  1. Confirm that the required product is the 24F / G.652.D1 / 100 m designation / 12.2 ± 0.5 mm record.
  2. Send the surveyed span schedule, ruling span, wind/ice and temperature basis, clearances and attachment locations.
  3. Keep all construction, optical and mechanical rows tied to this source revision; do not mix values from another ADSS page.
  4. Request engineering confirmation of fiber grade notation, bend radius, PMD units, load-test conditions, sheath construction and compatible hardware.
  5. Request the controlled drawing, current datasheet, test/document schedule, cable marking plan, drum plan and any route-specific calculation before PO approval.

RFQ checklist

Include:

  • selected configuration and source revision;
  • total cable length and required length per drum/roll;
  • quantity and delivery destination;
  • cable marking text and packaging requirements;
  • route spans, ruling span, wind/ice/temperature assumptions and clearances;
  • required fiber grade and sheath construction;
  • hardware scope, if hardware is to be quoted;
  • required drawings, test records, inspection documents and commercial terms.

Documents and QA

  • Datasheet: TBC — controlled file required
  • Cross-section drawing: TBC — controlled file required
  • Test report: TBC — controlled file required
  • Route sag/tension calculation: project-specific; not supplied

Request a configuration review

Send the selected 24F configuration, route/span schedule, load conditions, required length per drum, quantity and destination. Ask BWNFiber to confirm the controlled datasheet, drawing, test/document schedule and any unresolved engineering fields before approving the quotation.

FAQ

FAQ

Which fiber count does this page cover? This page covers the supplied 24F configuration. Other fiber counts are separate configurations and should not inherit this page’s values.

What does the 100 m span mean? It is the designation in the supplied product record. It is not a universal route approval; span, loading, sag, clearances and hardware must be reviewed for the actual route.

What diameter is listed? The outer diameter row is 12.2 ± 0.5 mm. Confirm the OD definition and unit in the controlled source before publication.

Which construction materials are listed? The record lists PBT loose tubes, FRP, Kevlar yarn, PE inner sheath, HDPE outer sheath, water-blocking yarn/gel and jelly filling compound. Engineering should confirm the controlled terminology and placement.

What attenuation values are supplied? The record lists ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm. These are source values pending confirmation of fiber-vs-cable test basis; they are not a complete link budget.

What tensile and crush values are supplied? Maximum tensile load is listed as 2,400 N and crush load as 2,200 N/100 mm. The source does not provide duration or test method, so do not call them RTS/MAT or continuous ratings.

What temperature range applies? The mechanical table lists −30 to +70 °C for installation and −40 to +70 °C for operation/transport. A construction row lists −40 to +75 °C for storage/transport; this conflict requires engineering confirmation.

Can I publish the PMD values? Not yet. The editorial review flags missing PMD units for the maximum individual-fiber, link-design and typical rows. Obtain the unit and test basis first.

Which bend radius should installers use? The source note contains 15D and 10D values with an unresolved long-/short-term ordering issue. Use the approved datasheet and installation method only after engineering resolves it.

Is the cable approved for power-line routes? The record identifies a self-supporting aerial application but does not approve a voltage, electrical field, attachment position or route load case. Obtain route-owner/engineering approval.

Can values from another ADSS page be combined with this page? No. Quote one complete 24F configuration and one controlled source revision.

What should I send for an accurate quotation? Send the configuration, length, drum/roll requirement, quantity, marking, destination, route/load inputs, sheath/fiber requirements, hardware scope, drawings, test documents and packaging terms.