ADSS
ADSS 24F / 48F / 96F G.652.D 50m Span Self-Supporting Fiber Optic Cable
ADSS 24F / 48F / 96F G.652.D 50m Span Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 24F / 48F / 96F. Specify span and fiber count against the source drawing.

Configuration at a glance
This page covers the BWNFiber ADSS configuration recorded as 24F / 48F / 96F, G.652.D fiber, HDPE outer sheath and a listed 50 m span. The fiber-count rows, cable dimensions and mechanical values must be confirmed against the approved source workbook before a quotation or installation design is released.
| Confirmed or source-listed field | Value | Status |
|---|---|---|
| Cable family | ADSS self-supporting aerial fiber optic cable | Source-listed |
| Fiber count | 24F / 48F / 96F | Source-listed; per-count mapping requires confirmation |
| Fiber type | G.652.D | Source-listed |
| Outer sheath | HDPE | Source-listed |
| Listed span | 50 m | Source-listed; not a route approval |
| Loose-tube construction | Yes | Source-listed |
| Strength member | Kevlar yarn | Source-listed |
| Central strength member | TBC — source row is unresolved | Engineering confirmation required |
Confirm the exact cable row before quotation
ADSS span is a design input, not a universal installation permission. Confirm the route’s maximum and ruling spans, wind and ice conditions, temperature range, attachment position, clearances and compatible hardware. The 24F, 48F and 96F options must not be combined with dimensions or mechanical values from another row.
The supplied source reading contains merged or sparse cells. The following fields remain intentionally open until the original workbook is checked:
- per-count number of loose tubes and fillers;
- loose-tube diameter where it varies by count;
- central strength member material;
- exact outer diameter by fiber count;
- tensile values and whether each is long-term or short-term;
- crush-load field name, duration and test method;
- PMD values and units, if included in the approved record.
Optical characteristics
The following values are retained from the supplied P059 page. They describe the listed fiber/cable record and do not replace a project link budget or terminated-link test plan.
| Parameter | Source-listed value |
|---|---|
| Attenuation at 1310 nm | ≤0.36 dB/km |
| Attenuation at 1550 nm | ≤0.25 dB/km |
| Maximum attenuation difference at 1285–1330 nm | ≤0.03 dB/km |
| Maximum attenuation difference at 1525–1575 nm | ≤0.02 dB/km |
| Zero-dispersion wavelength | 1312 ± 10 nm |
| Zero-dispersion slope | ≤0.090 ps/nm²·km |
| Cable cutoff wavelength | ≤1260 nm |
| MFD at 1310 nm | 9.2 ± 0.4 μm |
| MFD at 1550 nm | 10.4 ± 0.5 μm |
| Effective group index at 1310 nm | 1.466 |
| Effective group index at 1550 nm | 1.467 |
| Point discontinuities at 1310 / 1550 nm | ≤0.05 dB |
| Cladding diameter | 124.8 ± 0.7 μm |
| Cladding non-circularity | ≤0.7% |
| Coating diameter | 254 ± 5 μm |
| Coating-cladding concentricity error | ≤12.0 μm |
| Coating non-circularity | ≤6.0% |
| Core-cladding concentricity error | ≤0.5 μm |
| Curl radius | ≥4 m |
| PMD | TBC — unit and source row required |
Mechanical and environmental values
| Parameter | Source-listed value | Release status |
|---|---|---|
| Minimum bend radius, static | 10D | Confirm D basis and exact configuration |
| Minimum bend radius, dynamic | 20D | Confirm D basis and exact configuration |
| Installation temperature | −30 to +60 °C | Source-listed; confirm approved datasheet |
| Operation and transport temperature | −40 to +70 °C | Source-listed; confirm approved datasheet |
| Listed span | 50 m | Source-listed; route calculation required |
| Tensile strength, long term | TBC — source columns are ambiguous | do not use for order release as a final value |
| Tensile strength, short term | TBC — source columns are ambiguous | do not use for order release as a final value |
| Crush load | TBC — source field/method is ambiguous | do not use for order release as a final value |
| Cable diameter and weight | TBC by fiber count | Do not infer from another model |
What to send for an accurate quotation
Include:
- Selected fiber count: 24F, 48F or 96F.
- G.652.D requirement and any project fiber standard.
- Route drawing, pole or tower schedule, every span and the governing span.
- Wind, ice, temperature, UV, pollution and electrical-environment conditions where relevant.
- Attachment position, clearances, required sag and compatible suspension/dead-end hardware.
- Total cable length, length per drum or roll, quantity, marking text, packaging and destination.
- Required datasheet revision, test records, inspection plan and any contract or utility specification.
Ask BWNFiber to return one controlled configuration, not a mixture of values from the 24F, 48F and 96F rows. A listed 50 m span does not replace route-specific sag/tension review or line-owner approval.
For broader model selection, see the ADSS outdoor cable selection page and the fiber optic cable selection guide. Routes that are not self-supporting aerial installations should be reviewed against the FTTH drop cable range or the armored and direct-burial cable range, as applicable.
Request an ADSS configuration review
Send the selected fiber count, route spans, environmental load conditions, attachment details, total length, drum plan and destination. BWNFiber can then confirm whether the 50 m configuration and the requested documentation match the project requirement.
Specification notice: Published values are source-listed for this named configuration and remain subject to the approved datasheet, route calculation, hardware match, project specification and engineering confirmation. Unknown fields are not inferred from competitor or sibling-product data.
Frequently asked questions
Which fiber counts are covered?
The supplied P059 record lists 24F, 48F and 96F G.652.D options. Confirm the exact count before using dimensions, tube layout or mechanical values.
Does “50 m span” approve every aerial route?
No. It is the listed product configuration. Route approval also depends on span geometry, wind, ice, temperature, sag, clearances, attachment position and hardware.
What fiber type is listed?
The record lists G.652.D. Confirm whether the project specification requires another fiber grade before quotation; do not substitute G.657 or multimode fiber without approval.
What jacket and strength member are listed?
The supplied record lists an HDPE outer sheath and Kevlar yarn. The central-strength-member field is unresolved and requires engineering confirmation.
Which optical values are available?
The record lists attenuation limits of ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm, plus the optical characteristics in the table above. These are not a complete terminated-link loss budget.
What should a buyer request before release?
Request the approved datasheet, exact cross-section and bill of materials, per-count dimensions and mechanical values, route-specific sag/tension basis, compatible hardware, applicable test records, drum schedule and quotation exclusions.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.