ADSS-200m
ADSS-200m 96F All-Dielectric Self-Supporting Aerial Fiber Optic Cable
ADSS-200m 96F All-Dielectric Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 96F. Specify span and fiber count against the source drawing.

Product summary
The BWNFiber ADSS-200m 96F cable is an all-dielectric, self-supporting aerial fiber cable configuration for outdoor routes. This page is limited to the 96F configuration identified in the supplied record. The 200m designation identifies the model/span category; it does not approve a route or replace a project-specific sag-tension, clearance, electrical-environment and hardware review.
Short answer: confirm the fiber grade, exact cable construction, overall diameter, weight, MAT/RTS, environmental load case, hardware and drum plan as one controlled configuration before issuing a purchase order.
Key features — confirmed or conditional
- Fiber count: 96 fibers — supplied product record; confirm controlled source row.
- Tube plan: 8 tubes × 12 fibers/tube — supplied product record; confirm against the approved drawing.
- Construction: loose-tube outdoor ADSS — supplied record; confirm final BOM.
- Central strength member: FRP, listed as 2.1 mm in the supplied record — TBC; do not use for order release until reconciled with the drawing.
- Jacket/sheath: PE/HDPE is listed — confirm exact layer, material and thickness.
- Fiber choices: SM G.652.D, MM 50/125 and MM 62.5/125 are listed as alternatives — product owner must confirm which are orderable for this page.
Configuration table
| Field | Controlled value for publication |
|---|---|
| Product/model | ADSS-200m 96F — confirm part number |
| Product type | All-dielectric self-supporting aerial fiber optic cable |
| Fiber count | 96F / 96 fibers |
| Tube plan | 8 × 12 fibers/tube — confirm drawing |
| Fiber grade | SM G.652.D; MM 50/125; MM 62.5/125 listed as alternatives — confirmation required |
| Jacket/sheath | PE/HDPE listed — exact construction and thickness TBC |
| Overall cable diameter | TBC — conflicting values in supplied record |
| Cable weight | TBC — conflicting/duplicated source rows |
| MAT / RTS / EDS | TBC — source rows conflict and units/cases are not mapped |
| Installation / operation / storage temperature | TBC — labels and values require source confirmation |
| Minimum bend radius | TBC — installation and operation values require source confirmation |
| Standard drum length | 2 km listed — confirm tolerance, reel limits and configuration |
Fiber and optical options
The supplied record lists these optical alternatives:
| Fiber option | Wavelengths | Attenuation listed in supplied record | Status |
|---|---|---|---|
| SM G.652.D | 1310 / 1550 nm | ≤0.34 / 0.20 dB/km | Verify against approved fiber/cable datasheet |
| MM 50/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Confirm this option is genuinely orderable for this ADSS page |
| MM 62.5/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Confirm this option is genuinely orderable for this ADSS page |
These are alternatives, not values to combine in one order. Do not add dispersion, PMD, numerical aperture or other optical-matrix rows from the V4 review comment until units, conditions and source rows are reviewed.
Application and compatibility boundary
Use this page to identify and quote a 96F ADSS aerial-cable configuration. Route approval requires, at minimum, every span and ruling span, wind and ice cases, temperature, sag and clearance limits, attachment position, electrical environment where relevant, selected hardware, installation method and the exact approved cable record. All-dielectric construction does not by itself approve every power-line route or voltage environment.
This page does not specify connectors, polarity, gender, termination, splice closures, suspension clamps or dead-end hardware. Add those only from an approved accessory schedule or project drawing.
How to select the correct configuration
- Confirm that the route is self-supporting aerial rather than duct, buried, drop or indoor.
- Confirm 96 fibers and the required fiber grade; do not mix SM and MM alternatives.
- Send route spans, wind, ice, temperature, clearances, attachment position and hardware constraints.
- Match one approved cable drawing to the overall diameter, weight, sheath, tube plan, MAT, RTS and bend-radius values.
- Confirm the drum plan, marking, quantity, destination and required test/inspection file.
- Approve the quotation only after the cable, route calculation and hardware schedule describe the same configuration.
Differences from related products
This page is for one 96F/200m model configuration. The BWNFiber ADSS category page handles broad model selection by span, MAT, RTS and route. 100m/150m 96F pages and 200m pages with other fiber counts or construction must retain their own controlled values; do not transfer diameter, weight or tension data between them.
Testing and quality-control block
TBC — source required before publication: applicable optical, mechanical, environmental and water-blocking test methods; sample identity; test severity; acceptance limits; routine/type-test distinction; calibration and report format; and the document supplied with each drum. A generic standard logo or family brochure is not evidence for this exact configuration.
Packaging and procurement
The supplied record lists a standard drum length of 2 km. Confirm the permitted tolerance, maximum reel length, reel dimensions/weight, cable-end protection, marking, packing method and destination-specific logistics before quoting.
RFQ fields
Requesters should provide:
- Product:
ADSS-200m 96F All-Dielectric Self-Supporting Aerial Fiber Optic Cable - Fiber grade: one selected option, not a combined row
- Total length, section length per drum/roll and quantity
- Every span/ruling span, wind, ice, temperature and clearance requirement
- Attachment position/electrical environment where relevant
- Required sheath/jacket and any project standard
- Hardware/accessory scope and interface constraints
- Cable marking text and delivery destination
- Required datasheet, drawing, test report and inspection documents
Downloads and CTA
- Controlled product datasheet: TBC — source required
- Cable construction drawing: TBC — source required
- Route/sag-tension calculation template: TBC — confirm whether available
- Test/inspection report: TBC — request configuration-specific evidence
Primary CTA: Request the controlled 96F/200m datasheet and quotation.
Secondary CTA: Send the route and drum inputs for a configuration review.
CTA destination URL: TBC — confirm the approved RFQ/contact URL.
FAQ
What fiber count does this page cover?
This page is scoped to 96 fibers arranged as 8 tubes × 12 fibers/tube, subject to confirmation against the approved drawing. Other fiber counts are separate configurations.
Does “200m” approve a 200m aerial span?
No. It is a model/span category. Route approval requires the complete span, sag, wind, ice, temperature, clearance, electrical-environment and hardware review.
Which fiber grades are available?
The supplied record lists SM G.652.D, MM 50/125 and MM 62.5/125 as alternatives. Confirm the orderable option and final optical data before quoting.
What dimensions should be used for hardware selection?
Use the controlled overall cable diameter and the approved drawing. The supplied V4 record contains conflicting diameter fields, so no dimension should be released until reconciled.
Can I use the listed MAT or RTS in my sag-tension calculation?
Not yet. The supplied rows conflict and do not clearly map units and load cases. Use only the engineer-approved values for the exact part number.
What should be included in an RFQ?
Send fiber grade, total and drum lengths, quantity, route/load inputs, sheath, hardware/interface constraints, marking, destination and required evidence documents.
Is PE/HDPE proof of a fire or electrical rating?
No. Jacket material does not by itself prove flame, tracking, UV, water, halogen or power-line suitability. Request the exact tested classification or route assessment when required.
What documentation should accompany the cable?
Request the approved datasheet, drawing, configuration/BOM, applicable test and inspection records, drum schedule and deviation record. The exact file set is TBC until BWNFiber confirms it.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.