ADSS Cable

ADSS-200m 96F All-Dielectric Self-Supporting Aerial Fiber Optic Cable

ADSS-200m 96F All-Dielectric Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 96F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS-200m

Product summary

The BWNFiber ADSS-200m 96F cable is an all-dielectric, self-supporting aerial fiber cable configuration for outdoor routes. This page is limited to the 96F configuration identified in the supplied record. The 200m designation identifies the model/span category; it does not approve a route or replace a project-specific sag-tension, clearance, electrical-environment and hardware review.

Short answer: confirm the fiber grade, exact cable construction, overall diameter, weight, MAT/RTS, environmental load case, hardware and drum plan as one controlled configuration before issuing a purchase order.

Key features — confirmed or conditional

  • Fiber count: 96 fibers — supplied product record; confirm controlled source row.
  • Tube plan: 8 tubes × 12 fibers/tube — supplied product record; confirm against the approved drawing.
  • Construction: loose-tube outdoor ADSS — supplied record; confirm final BOM.
  • Central strength member: FRP, listed as 2.1 mm in the supplied record — TBC; do not use for order release until reconciled with the drawing.
  • Jacket/sheath: PE/HDPE is listed — confirm exact layer, material and thickness.
  • Fiber choices: SM G.652.D, MM 50/125 and MM 62.5/125 are listed as alternatives — product owner must confirm which are orderable for this page.

Configuration table

FieldControlled value for publication
Product/modelADSS-200m 96F — confirm part number
Product typeAll-dielectric self-supporting aerial fiber optic cable
Fiber count96F / 96 fibers
Tube plan8 × 12 fibers/tube — confirm drawing
Fiber gradeSM G.652.D; MM 50/125; MM 62.5/125 listed as alternatives — confirmation required
Jacket/sheathPE/HDPE listed — exact construction and thickness TBC
Overall cable diameterTBC — conflicting values in supplied record
Cable weightTBC — conflicting/duplicated source rows
MAT / RTS / EDSTBC — source rows conflict and units/cases are not mapped
Installation / operation / storage temperatureTBC — labels and values require source confirmation
Minimum bend radiusTBC — installation and operation values require source confirmation
Standard drum length2 km listed — confirm tolerance, reel limits and configuration

Fiber and optical options

The supplied record lists these optical alternatives:

Fiber optionWavelengthsAttenuation listed in supplied recordStatus
SM G.652.D1310 / 1550 nm≤0.34 / 0.20 dB/kmVerify against approved fiber/cable datasheet
MM 50/125850 / 1300 nm≤3.0 / 1.0 dB/kmConfirm this option is genuinely orderable for this ADSS page
MM 62.5/125850 / 1300 nm≤3.0 / 1.0 dB/kmConfirm this option is genuinely orderable for this ADSS page

These are alternatives, not values to combine in one order. Do not add dispersion, PMD, numerical aperture or other optical-matrix rows from the V4 review comment until units, conditions and source rows are reviewed.

Application and compatibility boundary

Use this page to identify and quote a 96F ADSS aerial-cable configuration. Route approval requires, at minimum, every span and ruling span, wind and ice cases, temperature, sag and clearance limits, attachment position, electrical environment where relevant, selected hardware, installation method and the exact approved cable record. All-dielectric construction does not by itself approve every power-line route or voltage environment.

This page does not specify connectors, polarity, gender, termination, splice closures, suspension clamps or dead-end hardware. Add those only from an approved accessory schedule or project drawing.

How to select the correct configuration

  1. Confirm that the route is self-supporting aerial rather than duct, buried, drop or indoor.
  2. Confirm 96 fibers and the required fiber grade; do not mix SM and MM alternatives.
  3. Send route spans, wind, ice, temperature, clearances, attachment position and hardware constraints.
  4. Match one approved cable drawing to the overall diameter, weight, sheath, tube plan, MAT, RTS and bend-radius values.
  5. Confirm the drum plan, marking, quantity, destination and required test/inspection file.
  6. Approve the quotation only after the cable, route calculation and hardware schedule describe the same configuration.

Differences from related products

This page is for one 96F/200m model configuration. The BWNFiber ADSS category page handles broad model selection by span, MAT, RTS and route. 100m/150m 96F pages and 200m pages with other fiber counts or construction must retain their own controlled values; do not transfer diameter, weight or tension data between them.

Testing and quality-control block

TBC — source required before publication: applicable optical, mechanical, environmental and water-blocking test methods; sample identity; test severity; acceptance limits; routine/type-test distinction; calibration and report format; and the document supplied with each drum. A generic standard logo or family brochure is not evidence for this exact configuration.

Packaging and procurement

The supplied record lists a standard drum length of 2 km. Confirm the permitted tolerance, maximum reel length, reel dimensions/weight, cable-end protection, marking, packing method and destination-specific logistics before quoting.

RFQ fields

Requesters should provide:

  • Product: ADSS-200m 96F All-Dielectric Self-Supporting Aerial Fiber Optic Cable
  • Fiber grade: one selected option, not a combined row
  • Total length, section length per drum/roll and quantity
  • Every span/ruling span, wind, ice, temperature and clearance requirement
  • Attachment position/electrical environment where relevant
  • Required sheath/jacket and any project standard
  • Hardware/accessory scope and interface constraints
  • Cable marking text and delivery destination
  • Required datasheet, drawing, test report and inspection documents

Downloads and CTA

  • Controlled product datasheet: TBC — source required
  • Cable construction drawing: TBC — source required
  • Route/sag-tension calculation template: TBC — confirm whether available
  • Test/inspection report: TBC — request configuration-specific evidence

Primary CTA: Request the controlled 96F/200m datasheet and quotation.
Secondary CTA: Send the route and drum inputs for a configuration review.
CTA destination URL: TBC — confirm the approved RFQ/contact URL.

FAQ

FAQ

What fiber count does this page cover?
This page is scoped to 96 fibers arranged as 8 tubes × 12 fibers/tube, subject to confirmation against the approved drawing. Other fiber counts are separate configurations.

Does “200m” approve a 200m aerial span?
No. It is a model/span category. Route approval requires the complete span, sag, wind, ice, temperature, clearance, electrical-environment and hardware review.

Which fiber grades are available?
The supplied record lists SM G.652.D, MM 50/125 and MM 62.5/125 as alternatives. Confirm the orderable option and final optical data before quoting.

What dimensions should be used for hardware selection?
Use the controlled overall cable diameter and the approved drawing. The supplied V4 record contains conflicting diameter fields, so no dimension should be released until reconciled.

Can I use the listed MAT or RTS in my sag-tension calculation?
Not yet. The supplied rows conflict and do not clearly map units and load cases. Use only the engineer-approved values for the exact part number.

What should be included in an RFQ?
Send fiber grade, total and drum lengths, quantity, route/load inputs, sheath, hardware/interface constraints, marking, destination and required evidence documents.

Is PE/HDPE proof of a fire or electrical rating?
No. Jacket material does not by itself prove flame, tracking, UV, water, halogen or power-line suitability. Request the exact tested classification or route assessment when required.

What documentation should accompany the cable?
Request the approved datasheet, drawing, configuration/BOM, applicable test and inspection records, drum schedule and deviation record. The exact file set is TBC until BWNFiber confirms it.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.