ADSS-150M
ADSS-150M 24F / 48F Single-Sheath Aerial Fiber Optic Cable
ADSS-150M 24F / 48F Single-Sheath Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 24F / 48F. Specify span and fiber count against the source drawing.

What this ADSS-150M record covers
The supplied BWNFiber record covers a single-sheath ADSS aerial cable in 24F and 48F configurations with a PE outer sheath. The ordering rows pair each fiber count with its own tube plan, dimensions, weight and source-listed mechanical values. Select one complete row for quotation; do not combine values from different rows.
150M is retained as the supplied product/design designation. It is not a universal approval for every 150 m aerial route. Final route suitability requires the surveyed spans, ruling span, wind and ice loads, temperature, sag, clearances, attachment position and compatible suspension/dead-end hardware. TBC — BWNFiber engineering must confirm the exact span basis.
Key fields from the supplied record
- Fiber-count options: 24F and 48F
- Outer sheath/jacket listed: PE
- Application listed: aerial installation / self-supporting aerial route
- Water-blocking material listed: swellable tape and yarn
- Strength-related fields in the record: aramid yarn and FRP dimensions; the exact role of each requires engineering confirmation
- Fiber grade, applicable standards, test methods, hardware interface and certification: TBC — source required
F and 48F configuration
| Parameter | 24F | 48F |
|---|---|---|
| Fibers per tube | 6 | 12 |
| Tube + filler count | 4 + 2 | 4 + 2 |
| Loose-tube size (mm) | 1.9 | 2.1 |
| FRP field listed (mm) | 2 | 2.2 |
| Sheath thickness (mm) | 1.6 | 1.6 |
| Cable diameter (mm) | 9.5 | 10 |
| Cable weight (kg/km) | 68 | 75 |
| Outer sheath | PE | PE |
| Strength-member material listed | Aramid yarn | Aramid yarn |
| Water-blocking material | Swellable tape and yarn | Swellable tape and yarn |
Source-review note: The same record describes the strength material as aramid yarn while also listing FRP dimensions. Confirm whether these are separate central/peripheral elements and confirm the controlled construction drawing before publication.
Optical values in the supplied record
The supplied table lists the following values: mode-field diameter at 1310 nm of 9.2 ± 0.4 μm; cladding diameter of 125 ± 1 μm; attenuation of ≤0.36 dB/km (max.) at 1310 nm and ≤0.21 dB/km (max.) at 1550 nm; chromatic dispersion of ≤3.5 ps/nm·km within 1288–1339 nm and ≤17 ps/nm·km at 1550 nm; zero-dispersion wavelength of 1300–1324 nm; zero-dispersion slope of ≤0.092 ps/nm²·km; and coating dimensions as shown in the source table.
These values are reproduced for source review. They must not be described as a finished-cable acceptance result until BWNFiber confirms the fiber grade, test method, sample identity and whether each row is fiber-level or cable-level.
Mechanical and environmental limits
| Parameter | Source-listed value |
|---|---|
| Maximum allowed tensile | 2,000 N |
| Crush resistance | 1,000 N/100 mm |
| Minimum bend radius, dynamic | 20 × cable diameter |
| Minimum bend radius, static | 10 × cable diameter |
| Operation temperature | −30°C to +60°C |
| Installation temperature | −30°C to +60°C |
| Storage temperature | −40°C to +70°C |
| Macro-bending loss | ≤0.1 dB at Φ=60 mm, 100 turns, 1550 nm |
The label maximum allowed tensile is preserved from the source. Do not relabel it as MAT or RTS without engineering confirmation. Route loading, sag, wind, ice, clearance, attachment and hardware remain project-specific.
How to confirm route fit before ordering
- Provide every span, the ruling span, route angles, clearances and attachment position.
- State wind, ice, temperature, altitude, pollution and any utility-owner constraints.
- Select one fiber-count row and carry its diameter, weight, tube plan and mechanical values together.
- Confirm fiber grade, central/peripheral strength construction, sheath definition and compatible hardware against the controlled drawing.
- Request the approved datasheet, cross-section, route calculation inputs, test/document schedule and drum plan before purchase-order release.
For broad ADSS selection by span, MAT/RTS, route and hardware, use the approved category resource: ADSS cable selection by span, MAT, RTS and route.
For broader route-family comparison, see fiber optic cable selection for FTTx projects. For associated support hardware and BOM review, see FTTx installation hardware and route BOM review. If the project is a subscriber drop rather than a self-supporting feeder route, compare FTTH drop cable options instead.
RFQ checklist
Include the selected fiber count, total cable length, length per drum or roll, quantity, cable marking, delivery destination, fiber grade, route/span schedule, load conditions, hardware scope, required drawings, test records, packaging and commercial terms. Ask BWNFiber to identify the controlling document revision and any deviation from the selected row.
Do not approve the order by combining 24F diameter/weight with 48F tube or tensile values.
Application boundary
This record is for self-supporting aerial routes. It does not establish suitability for duct, direct-buried, FTTH drop, armored, indoor or data-center applications. ADSS construction alone does not approve a particular utility voltage, attachment position or route. The route owner or qualified engineer must approve the installed system.
Primary CTA
Request an ADSS-150M configuration review — send the selected fiber count, route/span schedule, load conditions, required length per drum, quantity and destination. Ask for the controlled datasheet, drawing and document/test schedule before approving the quotation.
FAQ
Which fiber counts does this page cover? The supplied record covers 24F and 48F. Select one complete configuration row.
Does ADSS-150M guarantee a 150 m aerial span? No. The designation is not route approval. Confirm the span/design basis, load case, sag, clearances, attachment and hardware.
Which jacket is listed? PE is listed for the outer sheath. Confirm the exact sheath construction in the controlled drawing.
What are the cable diameters and weights? The supplied table lists 9.5 mm and 68 kg/km for 24F, and 10 mm and 75 kg/km for 48F.
What tensile value is listed? The source lists a maximum allowed tensile of 2,000 N. Do not call it MAT or RTS without confirmation.
What bend-radius values are listed? Dynamic minimum bend radius is 20 × cable diameter and static minimum bend radius is 10 × cable diameter.
What fiber grade is used? The visible record does not safely confirm it. TBC — source required. Do not infer G.652.D from the image filename.
Can this cable be used near power lines? ADSS is an aerial all-dielectric category, but this record does not approve a voltage, attachment position or electrical environment. Obtain route-owner/engineering approval.
What should a quotation include? Fiber count, total and drum lengths, quantity, marking, destination, route/load inputs, construction, hardware, drawings, test evidence and commercial terms.
Can values from two configuration columns be combined? No. Quote one complete fiber-count row.