ADSS-150
ADSS-150 144F All-Dielectric Self-Supporting Aerial Fiber Optic Cable
ADSS-150 144F All-Dielectric Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 144F. Specify span and fiber count against the source drawing.

Product summary
This page covers the recorded ADSS-150 144F all-dielectric self-supporting aerial fiber optic cable configuration. The supplied BWNFiber record identifies 144 fibers, a loose-tube construction, an FRP central strength member, PE/HDPE sheath entries and a 2 km standard drum length. It also records SM G.652.D, MM 50/125 and MM 62.5/125 as fiber options. These are alternatives for quotation; they must not be combined into one assumed cable build. For the broader family, see the ADSS outdoor cable selection page.
ADSS suitability is route-specific. Confirm span, wind and ice loading, sag-tension conditions, installation method, electrical environment and compatible attachment hardware before approving a production configuration. The model label is not a universal span or load approval.
Configuration snapshot
| Item | Supplied record | Release state |
|---|---|---|
| Product | ADSS-150 144F all-dielectric self-supporting aerial fiber optic cable | Product identity supplied |
| Fiber count | 144F / 144 cores | Confirm against approved datasheet |
| Fiber options | SM G.652.D; MM 50/125; MM 62.5/125 | Select one; order matrix required |
| Tube arrangement | 12 tubes; 12 fibers per tube | Confirm drawing/table alignment |
| Central member | FRP, 2.0 mm diameter | Confirm BOM and drawing |
| Loose tube | PBT; Ф2.0 (outer/inner) recorded | Confirm notation and dimensions |
| Inner sheath | PE | Confirm exact build |
| Outer sheath | PE/HDPE alternatives recorded | Select one approved construction |
| Moisture protection | Water-blocking system and filling compounds recorded | Confirm construction drawing |
| Outer-sheath diameter | 2.10 +/- 0.2 mm appears in the supplied table | Engineering review required; likely field/unit conflict |
| Drum length | 2 km standard length | Confirm packing availability |
What this product page does—and does not—cover
This is a configuration page for a 144F ADSS product record. It is not the owner for the broad ADSS cable category, a general span-selection guide, an ADSS-versus-OPGW comparison, or a universal installation standard. Those topics should remain on their own approved URLs and be linked only where useful. Buyers comparing route families can start with BWNFiber’s fiber optic cable selection range.
Construction and fiber options
The supplied record lists PBT loose tubes, an FRP central strength member, PE inner sheath, PE/HDPE outer-sheath alternatives, tube-filling compound, cable-filling compound and a water-blocking system. The 144F construction table records 12 tubes with 12 fibers per tube and G.652.D. Because the SEO data also lists two multimode alternatives, the approved source must state which fiber grade and sheath construction are orderable together.
Selection rule: choose one fiber grade, one sheath construction and one approved mechanical design. Do not create a configuration by combining values from different source rows.
Optical characteristics
The supplied record contains these rows, pending engineering/source verification:
| Fiber option | Wavelength | Recorded attenuation |
|---|---|---|
| SM G.652.D | 1310 / 1550 nm | ≤0.34 / 0.20 dB/km |
| MM 50/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km |
| MM 62.5/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km |
TBC — source required: the editorial note flags additional optical rows and requires review of units, conditions and mapping. Do not use this table as a final link budget until an approved datasheet or test record maps each value to the exact fiber grade, wavelength, test method and orderable build.
Environmental and mechanical validation
The record lists an installation temperature range of -15 to +60 and an operation/transport range of -40 to +70; units and condition definitions must be confirmed. The record also contains multiple mechanical rows and an editorial warning about unresolved optical and mechanical data. No tension, span, ice or wind value is published here as a guaranteed design rating.
For an aerial design review, submit:
- Pole or structure spacing and the longest span.
- Wind and ice loading assumptions and the governing local design basis.
- Installation method, allowable installation tension and sag-tension calculation.
- Electrical environment and required sheath type.
- Fiber grade, link budget and termination plan.
- Attachment hardware, drum plan, marking and destination.
How to select this configuration
- Confirm that the route needs 144F ADSS rather than a different fiber count, figure-8 cable, duct cable or buried construction.
- Select one approved fiber option: SM G.652.D, MM 50/125 or MM 62.5/125.
- Confirm the exact tube, inner-sheath, outer-sheath and diameter values against the approved drawing. The supplied
2.10 +/- 0.2 mmouter-sheath entry requires correction before use. - Submit the route load case and hardware requirements. Do not infer an allowable span from
ADSS-150alone. - Approve the final datasheet, optical mapping, mechanical values, packing and marking before production.
RFQ checklist
Send BWNFiber through the project RFQ and contact path:
- Product name:
ADSS-150 144F All-Dielectric Self-Supporting Aerial Fiber Optic Cable. - One selected fiber grade and the required optical performance.
- Total cable length, length per drum or roll and quantity.
- Route span, wind/ice conditions, installation method and electrical environment.
- Inner/outer sheath requirement and dimensional constraints.
- Cable marking text, packing requirements and delivery destination.
- Request for the approved datasheet, construction drawing and applicable optical/mechanical test documents.
Documents and image
TBC — source required: add approved links for the datasheet, construction drawing, optical test report and mechanical/sag-tension document. Do not label an internal draft or unreviewed table as a datasheet or test report.
Reuse the supplied image only after confirming that it depicts this exact ADSS-150 144F configuration and that the asset is approved for publication. Suggested alt text: ADSS-150 144F all-dielectric self-supporting aerial fiber optic cable product view. Hardware and route-BOM questions should remain on the separate FTTx supporting-products page.
CTA
Request an ADSS-150 144F configuration review and quotation. Send the selected fiber grade, total length, drum requirement, route span, loading conditions, sheath requirement, marking text and destination. BWNFiber can then return the configuration documents and quotation inputs applicable to that request.
Technical disclaimer: Product-record values on this offline draft are subject to approved source-document and engineering review. They are not a universal span, load, link-budget or compliance guarantee.
FAQ
What fiber count does this ADSS-150 page cover?
It covers the 144F configuration recorded in the supplied product file. Other fiber counts or construction designs should be quoted as separate configurations unless the approved product matrix says otherwise.
Does “150” prove a permitted 150 m span?
No. Treat the model designation as a product-record identifier until the approved datasheet defines its span class. Final aerial suitability depends on span, wind and ice loading, sag, installation tension, electrical environment and hardware.
Can the SM and multimode values be combined?
No. They are alternative fiber options. Select one approved fiber grade and request the matching construction and optical data.
What is the tube arrangement?
The supplied table records 12 tubes with 12 fibers per tube. Confirm the arrangement and fiber grade against the approved construction drawing.
Which sheath should a buyer select?
The record lists PE/HDPE alternatives. Select the sheath required by the approved electrical and environmental design; do not combine alternatives in one quotation without written confirmation.
Can the listed attenuation values be used for a link budget?
Not yet. The optical editorial note requires unit, condition and fiber-grade mapping review. Use the values only after the approved source packet confirms their applicability.
Which mechanical load value should be used?
None of the unresolved values should be used as a final design input. Request the corrected value with units, duration, loading condition, test method and engineering approval.
What temperature conditions apply?
The record lists -15 to +60 for installation and -40 to +70 for operation/transport. Confirm units and definitions before inserting them into a project specification.
What drum length is recorded?
The record lists a 2 km standard drum length. Confirm actual packing availability and any cut-length requirement in the quotation.
What documents should accompany an RFQ?
Request the approved datasheet, construction drawing, optical test data and mechanical/sag-tension information applicable to the selected fiber grade and route design.
Related Products